Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Masaru Isono, Yuichi Akino, Hirokazu Mizuno, Yoshihiro Tanaka, Norihisa Masai, Toshijiro Yamamot. Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey. Journal of radiation research. vol 61. issue 2. 2020-12-04. PMID:31927580. |
inter-unit variability of multi-leaf collimator parameters for imrt and vmat treatment planning: a multi-institutional survey. |
2020-12-04 |
2023-08-13 |
Not clear |
R Lee MacDonald, Alasdair Syme, Brian Little, Lucy Ward, Christopher G Thoma. Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories. Medical physics. vol 47. issue 2. 2020-11-23. PMID:31659750. |
to develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (vmat) treatment planning. |
2020-11-23 |
2023-08-13 |
Not clear |
Adams Hei Long Yuen, Po Man Wu, Alex Kai Leung Li, Philip Chung Yin Ma. Volumetric modulated arc therapy (VMAT) for hippocampal-avoidance whole brain radiation therapy: planning comparison with Dual-arc and Split-arc partial-field techniques. Radiation oncology (London, England). vol 15. issue 1. 2020-10-30. PMID:32070385. |
volumetric modulated arc therapy (vmat) for hippocampal-avoidance whole brain radiation therapy: planning comparison with dual-arc and split-arc partial-field techniques. |
2020-10-30 |
2023-08-13 |
Not clear |
Phillip D H Wall, Jonas D Fonteno. Evaluation of complexity and deliverability of prostate cancer treatment plans designed with a knowledge-based VMAT planning technique. Journal of applied clinical medical physics. vol 21. issue 1. 2020-10-26. PMID:31816175. |
evaluation of complexity and deliverability of prostate cancer treatment plans designed with a knowledge-based vmat planning technique. |
2020-10-26 |
2023-08-13 |
Not clear |
Zi Ouyang, Danielle V LaHurd, Ehsan H Balagamwala, Samuel T Chao, John H Suh, Ping Xi. Treatment planning of VMAT and step-and-shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom-based quality assurance measurements. Journal of applied clinical medical physics. vol 21. issue 1. 2020-10-26. PMID:31821729. |
treatment planning of vmat and step-and-shoot imrt delivery techniques for single fraction spine sbrt: an intercomparative dosimetric analysis and phantom-based quality assurance measurements. |
2020-10-26 |
2023-08-13 |
Not clear |
Luise A Künzel, Sara Leibfarth, Oliver S Dohm, Arndt-Christian Müller, Daniel Zips, Daniela Thorwart. Automatic VMAT planning for post-operative prostate cancer cases using particle swarm optimization: A proof of concept study. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 69. 2020-10-26. PMID:31862575. |
automatic vmat planning for post-operative prostate cancer cases using particle swarm optimization: a proof of concept study. |
2020-10-26 |
2023-08-13 |
Not clear |
Luise A Künzel, Sara Leibfarth, Oliver S Dohm, Arndt-Christian Müller, Daniel Zips, Daniela Thorwart. Automatic VMAT planning for post-operative prostate cancer cases using particle swarm optimization: A proof of concept study. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 69. 2020-10-26. PMID:31862575. |
to investigate the potential of particle swarm optimization (pso) for fully automatic vmat radiotherapy (rt) treatment planning. |
2020-10-26 |
2023-08-13 |
Not clear |
Mehrdad Malekmohammadi, Keivan Dabiri, Joshua Mathews, Daryl P Nazareth, Hirotaka Tamura, Ali Sheikholeslam. A Hamiltonian Engine for Radiotherapy Optimization. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. vol 2020. 2020-10-26. PMID:33019130. |
additionally, hero has the potential to be applied to volumetric-modulated arc therapy (vmat) and other complex types of treatment planning. |
2020-10-26 |
2023-08-13 |
Not clear |
Yong Hou, Yan Zhang, Zhen Liu, Lili Yv, Kun Liu, Xiufang Tian, Yajuan L. Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison. Clinical neurology and neurosurgery. vol 187. 2020-10-16. PMID:31706107. |
advanced techniques such as volumetric-modulated arc therapy (vmat) may reduce radiation damage and improve the quality of life for patients.we performed a study comparing dose distributions to the planning target volumes(ptvs) and other organs at risk (oars) of intensity-modulated radiotherapy (imrt),coplanar vmat (covmat), and non-coplanar vmat (ncvmat). |
2020-10-16 |
2023-08-13 |
Not clear |
David Y Mak, Ian Fraser, Robynn Ferris, Kerry James, Mitchell Liu, Steven D Thomas, Michael McKenzie, Shilo Lefresn. Comparison of Rapid to Standard Volumetric Modulated Arc Therapy for Palliative Radiotherapy in Lung Cancer Patients. Cureus. vol 12. issue 8. 2020-10-02. PMID:32999778. |
volumetric modulated arc therapy (vmat) provides several dosimetric advantages compared to basic non-conformal techniques, but involves complex planning resulting in a slower turn-around time for treatment. |
2020-10-02 |
2023-08-13 |
Not clear |
David Y Mak, Ian Fraser, Robynn Ferris, Kerry James, Mitchell Liu, Steven D Thomas, Michael McKenzie, Shilo Lefresn. Comparison of Rapid to Standard Volumetric Modulated Arc Therapy for Palliative Radiotherapy in Lung Cancer Patients. Cureus. vol 12. issue 8. 2020-10-02. PMID:32999778. |
a simplified planning technique known as 'rapid vmat' was developed with an aim to deliver palliative treatment to patients within 48 hours. |
2020-10-02 |
2023-08-13 |
Not clear |
David Y Mak, Ian Fraser, Robynn Ferris, Kerry James, Mitchell Liu, Steven D Thomas, Michael McKenzie, Shilo Lefresn. Comparison of Rapid to Standard Volumetric Modulated Arc Therapy for Palliative Radiotherapy in Lung Cancer Patients. Cureus. vol 12. issue 8. 2020-10-02. PMID:32999778. |
fourteen consecutive rapid vmat cases were re-planned de novo as per standard vmat planning guidelines. |
2020-10-02 |
2023-08-13 |
Not clear |
Sangroh Kim, Tzu-Chi Tsen. Off-target-isocentric approach in non-coplanar Volumetric Modulated Arc Therapy (VMAT) planning for lung SBRT treatments. Journal of radiosurgery and SBRT. vol 3. issue 3. 2020-10-01. PMID:29296404. |
off-target-isocentric approach in non-coplanar volumetric modulated arc therapy (vmat) planning for lung sbrt treatments. |
2020-10-01 |
2023-08-13 |
Not clear |
Sangroh Kim, Tzu-Chi Tsen. Off-target-isocentric approach in non-coplanar Volumetric Modulated Arc Therapy (VMAT) planning for lung SBRT treatments. Journal of radiosurgery and SBRT. vol 3. issue 3. 2020-10-01. PMID:29296404. |
volumetric modulated arc therapy (vmat) has emerged as an efficient alternative to traditional three-dimensional (3d) non-coplanar conformal (3d-nc-c) beams for lung cancer stereotactic body radiotherapy (sbrt) because of its superior dosimetric properties and native ease in planning and treatment delivery. |
2020-10-01 |
2023-08-13 |
Not clear |
Peng Dong, Sabbir Hossain, Vance Keeling, Salahuddin Ahmad, Lei Xing, Lijun M. Minimizing normal tissue dose spillage via broad-range optimization of hundreds of intensity modulated beams for treating multiple brain targets. Journal of radiosurgery and SBRT. vol 4. issue 2. 2020-10-01. PMID:29296435. |
the broomba planning results was compared with vmat treatment plans of the same case using coplanar and non-coplanar arc beams. |
2020-10-01 |
2023-08-13 |
Not clear |
Peng Dong, Sabbir Hossain, Vance Keeling, Salahuddin Ahmad, Lei Xing, Lijun M. Minimizing normal tissue dose spillage via broad-range optimization of hundreds of intensity modulated beams for treating multiple brain targets. Journal of radiosurgery and SBRT. vol 4. issue 2. 2020-10-01. PMID:29296435. |
for example, when planning simultaneous treatment of 12 targets, broomba lowered the normal brain dose by as much as 65% versus conventional vmat treatment plans and the dose interplay effects across 8 gy to 12 gy levels was reduced to be negligible. |
2020-10-01 |
2023-08-13 |
Not clear |
Vance Keeling, Ozer Algan, Salahuddin Ahmad, Sabbir Hossai. Dosimetric comparison of intracranial metastasis treatment using two radiosurgery systems: TrueBeam STx with VMAT and Gamma Knife Model 4C. Journal of radiosurgery and SBRT. vol 4. issue 3. 2020-10-01. PMID:29296448. |
ten patients with 24 tumors (seven with 1-2 and three with 4-6 ranging from 0.1 to 20.2 cc), previously treated with gk model 4c (prescription doses ranging from 14-23 gy), were re-planned for vmat using eclipse treatment planning system. |
2020-10-01 |
2023-08-13 |
Not clear |
Sara Jiménez-Puertas, David Sánchez-Artuñedo, Marcelino Hermida-Lópe. Assessment of the Monitor Unit Objective tool for VMAT in the Eclipse treatment planning system. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 23. issue 2. 2020-10-01. PMID:29556140. |
assessment of the monitor unit objective tool for vmat in the eclipse treatment planning system. |
2020-10-01 |
2023-08-13 |
Not clear |
P Mohandass, D Khanna, T Manoj Kumar, T Thiyagaraj, C Saravanan, Narendra Kumar Bhalla, Abhishek Pur. Study to Compare the Effect of Different Registration Methods on Patient Setup Uncertainties in Cone-beam Computed Tomography during Volumetric Modulated Arc Therapy for Breast Cancer Patients. Journal of medical physics. vol 43. issue 4. 2020-10-01. PMID:30636845. |
this study compared three different methods used in registering cone-beam computed tomography (cbct) image set with planning ct image set for determining patient setup uncertainties during volumetric modulated arc therapy (vmat) for breast cancer patients. |
2020-10-01 |
2023-08-13 |
Not clear |
Alex Dunlop, Ruth Colgan, Anna Kirby, Alison Ranger, Irena Blasiak-Wa. Evaluation of organ motion-based robust optimisation for VMAT planning for breast and internal mammary chain radiotherapy. Clinical and translational radiation oncology. vol 16. 2020-10-01. PMID:31032432. |
evaluation of organ motion-based robust optimisation for vmat planning for breast and internal mammary chain radiotherapy. |
2020-10-01 |
2023-08-13 |
Not clear |