Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Lana C Critchfield, Mark E Bernard, Marcus E Randall, Ronald C McGarry, Damodar Pokhre. Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single-isocenter volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 22. issue 1. 2021-06-21. PMID:33342042. |
for comparison, a plan summation (simulated vmat) was executed utilizing randomly simulated, clinically relevant setup errors, obtained from pretreatment setup, per treatment fraction, in eclipse treatment planning system for each of the six degrees of freedom within ± 5.0 mm and ± 2°. |
2021-06-21 |
2023-08-13 |
Not clear |
Lana C Critchfield, Mark E Bernard, Marcus E Randall, Ronald C McGarry, Damodar Pokhre. Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single-isocenter volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 22. issue 1. 2021-06-21. PMID:33342042. |
although, clinical follow-up of these patients is ongoing, the authors recommend an alternative treatment planning strategy to minimize the probability of a geometric miss when treating small lung lesions synchronously with single-isocenter vmat sbrt plans. |
2021-06-21 |
2023-08-13 |
Not clear |
Jose R Teruel, Sameer Taneja, Paulina E Galavis, K Sunshine Osterman, Allison McCarthy, Martha Malin, Naamit K Gerber, Christine Hitchen, David L Barbe. Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting. Journal of applied clinical medical physics. vol 22. issue 3. 2021-06-21. PMID:33565214. |
the purpose of this work is to establish an automated approach for a multiple isocenter volumetric arc therapy (vmat)-based tbi treatment planning approach. |
2021-06-21 |
2023-08-13 |
Not clear |
Xue-Ying Ren, Peng-Kang He, Xian-Shu Gao, Zhi-Lei Zhao, Bo Zhao, Yun Bai, Si-Wei Liu, Kang Li, Shang-Bin Qin, Ming-Wei Ma, Jing Zhou, Yi Ron. Dosimetric feasibility of stereotactic ablative radiotherapy in pulmonary vein isolation for atrial fibrillation using intensity-modulated proton therapy. Journal of applied clinical medical physics. vol 22. issue 5. 2021-06-21. PMID:33817981. |
to evaluate dosimetric properties of intensity-modulated proton therapy (impt) for simulated treatment planning in patients with atrial fibrillation (af) targeting left atrial-pulmonary vein junction (la-pvj), in comparison with volumetric-modulated arc therapy (vmat) and helical tomotherapy (tomo). |
2021-06-21 |
2023-08-13 |
Not clear |
Qi Fu, Deqi Chen, Hui Yan, Jiayun Chen, Ji Zhu, Lingling Yan, Yingjie Xu, Lei Deng, Kuo Men, Jianrong Da. Treatment planning of volumetric modulated arc therapy and positioning optimization for hippocampal-avoidance prophylactic cranial irradiation. Journal of applied clinical medical physics. vol 22. issue 5. 2021-06-21. PMID:33829650. |
this study aims to improve the conventional planning method using volumetric modulated arc therapy (vmat) technique and investigate a better patient's head positioning to achieve a high quality of ha-pci treatment plans. |
2021-06-21 |
2023-08-13 |
Not clear |
V Passal, M Barreau, T Tiplica, S Dufrenei. Optimizing the effective spot size and the dosimetric leaf gap of the AcurosXB algorithm for VMAT treatment planning. Journal of applied clinical medical physics. vol 22. issue 6. 2021-06-21. PMID:34042259. |
optimizing the effective spot size and the dosimetric leaf gap of the acurosxb algorithm for vmat treatment planning. |
2021-06-21 |
2023-08-13 |
Not clear |
Ghulam Murtaza, Zaheer Abbas Gillani, Shahid Mehmood, Ehsan Ullah Kha. Optimisation of user-selectable volumetric modulated arc therapy (VMAT) planning parameters: VMAT arcs for prostate and head-and-neck cancers. JPMA. The Journal of the Pakistan Medical Association. vol 71. issue 4. 2021-06-16. PMID:34125749. |
optimisation of user-selectable volumetric modulated arc therapy (vmat) planning parameters: vmat arcs for prostate and head-and-neck cancers. |
2021-06-16 |
2023-08-13 |
Not clear |
Ghulam Murtaza, Zaheer Abbas Gillani, Shahid Mehmood, Ehsan Ullah Kha. Optimisation of user-selectable volumetric modulated arc therapy (VMAT) planning parameters: VMAT arcs for prostate and head-and-neck cancers. JPMA. The Journal of the Pakistan Medical Association. vol 71. issue 4. 2021-06-16. PMID:34125749. |
to evaluate different vmat planning techniques for a multi-leaf collimator (mlc)providing maximum aperture of 21 × 16 cm². |
2021-06-16 |
2023-08-13 |
Not clear |
Masahide Saito, Toshihiro Suzuki, Yuya Sugama, Kan Marino, Naoki Sano, Takafumi Komiyama, Shinichi Aoki, Yoshiyasu Maehata, Kazuya Yoshizawa, Kazunari Ashizawa, Hidekazu Suzuki, Koji Ueda, Yosuke Miyasaka, Masayuki Araya, Hiroshi Takahashi, Hiroshi Onish. Comparison of rectal dose reduction by a hydrogel spacer among 3D conformal radiotherapy, volumetric-modulated arc therapy, helical tomotherapy, CyberKnife and proton therapy. Journal of radiation research. vol 61. issue 3. 2021-06-08. PMID:32211861. |
in total, 200 plans (20 patients × 2 ct images × 5 techniques) were created using the following criteria: 3dcrt, vmat and ht [76 gy/38 fractions (fr), planning target volume (ptv) d50%], ck (36.25 gy/5 fr, ptv d95%) and proton therapy (63 gye/21 fr, ptv d50%). |
2021-06-08 |
2023-08-13 |
Not clear |
Takuya Uehara, Hajime Monzen, Mikoto Tamura, Kazuki Ishikawa, Hiroshi Doi, Yasumasa Nishimur. Dose-volume histogram analysis and clinical evaluation of knowledge-based plans with manual objective constraints for pharyngeal cancer. Journal of radiation research. vol 61. issue 3. 2021-06-08. PMID:32329509. |
for another 15 patients, dvh parameters of kbpconst and kbporig from a single optimization were compared with cmo plans with respect to the planning target volume (d98%, d50%, d2%), brainstem maximum dose (dmax), spinal cord dmax, parotid gland median and mean dose (dmed and dmean), monitor units and modulation complexity score for vmat. |
2021-06-08 |
2023-08-13 |
Not clear |
Rubi Ramos-Prudencio, Sandra Ileana Pérez-Álvarez, Christian Haydée Flores-Balcazar, Mayra Angélica de León-Alfaro, José Alfredo Herrera-González, Jonathan Elizalde-Cabrera, Johnatan Rubalcava-Ortega, Lissett Espinoza-Alvarado, Ricardo Iván Balderrama-Ibarr. Radiotherapy for the treatment of pituitary adenomas: A dosimetric comparison of three planning techniques. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 25. issue 4. 2021-06-04. PMID:32508534. |
our goal was to compare conformal 3d (c3d) radiotherapy (rt), modulated intensity rt (imrt), and volumetric modulated arc therapy (vmat) planning techniques in treating pituitary adenomas. |
2021-06-04 |
2023-08-13 |
Not clear |
Motoharu Sasaki, Hitoshi Ikushima, Akira Tsuzuki, Wataru Sugimot. The effect of rectal gas on dose distribution during prostate cancer treatment using full arc and partial arc Volumetric Modulated Arc Therapy (VMAT) treatment plans. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 25. issue 6. 2021-06-02. PMID:33100914. |
in this study, we investigated the effect of rectal gas on the dose distribution of prostate cancer using a volumetric modulated arc therapy (vmat) treatment planning. |
2021-06-02 |
2023-08-13 |
Not clear |
Shoki Inui, Yoshihiro Ueda, Shingo Ohira, Haruhi Tsuru, Masaru Isono, Masayoshi Miyazaki, Masahiko Koizumi, Teruki Teshim. Novel strategy with the automatic non-coplanar volumetric-modulated arc therapy for angiosarcoma of the scalp. Radiation oncology (London, England). vol 15. issue 1. 2021-05-31. PMID:32680542. |
while reports suggest that hyperarc, a new stereotactic radiosurgery planning technique applied to non-coplanar volumetric-modulated arc therapy (vmat) technique, is associated with high conformity and rapid dose fall-off, the performance of hyperarc for total scalp irradiation has not been explored. |
2021-05-31 |
2023-08-13 |
Not clear |
Yunfeng Cui, Hao Gao, Jiahan Zhang, John P Kirkpatrick, Fang-Fang Yi. Retrospective quality metrics review of stereotactic radiosurgery plans treating multiple targets using single-isocenter volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 21. issue 6. 2021-05-26. PMID:32239746. |
to investigate the feasibility of quality improvement in vmat planning based on previous planning knowledge. |
2021-05-26 |
2023-08-13 |
Not clear |
Livia Marrazzo, Chiara Arilli, Roberto Pellegrini, Pierluigi Bonomo, Silvia Calusi, Cinzia Talamonti, Marta Casati, Antonella Compagnucci, Lorenzo Livi, Stefania Pallott. Automated planning through robust templates and multicriterial optimization for lung VMAT SBRT of lung lesions. Journal of applied clinical medical physics. vol 21. issue 6. 2021-05-26. PMID:32275353. |
automated planning through robust templates and multicriterial optimization for lung vmat sbrt of lung lesions. |
2021-05-26 |
2023-08-13 |
Not clear |
Livia Marrazzo, Chiara Arilli, Roberto Pellegrini, Pierluigi Bonomo, Silvia Calusi, Cinzia Talamonti, Marta Casati, Antonella Compagnucci, Lorenzo Livi, Stefania Pallott. Automated planning through robust templates and multicriterial optimization for lung VMAT SBRT of lung lesions. Journal of applied clinical medical physics. vol 21. issue 6. 2021-05-26. PMID:32275353. |
to develop and validate a robust template for vmat sbrt of lung lesions, using the multicriterial optimization (mco) of a commercial treatment planning system. |
2021-05-26 |
2023-08-13 |
Not clear |
Joel Mullins, Marc-André Renaud, Monica Serban, Jan Seuntjen. Simultaneous trajectory generation and volumetric modulated arc therapy optimization. Medical physics. vol 47. issue 7. 2021-05-14. PMID:32215936. |
trajectory-based treatment planning involves the combination of a gantry-couch trajectory with volumetric modulated arc therapy (vmat) treatment plan optimization. |
2021-05-14 |
2023-08-13 |
Not clear |
Joshua Mathews, Samuel B French, Stephen Bhagroo, Ankit Pant, Daryl P Nazaret. Enhanced optimization of volumetric modulated arc therapy plans using Monte Carlo generated beamlets. Medical physics. vol 47. issue 12. 2021-05-14. PMID:32978967. |
a treatment planning system (tps) produces volumetric modulated arc therapy (vmat) plans by applying an optimization process to an objective function, followed by an accurate calculation of the final, deliverable dose. |
2021-05-14 |
2023-08-13 |
Not clear |
Nicholas Bucknell, Nicholas Hardcastle, Price Jackson, Michael Hofman, Jason Callahan, Peter Eu, Amir Iravani, Rhonda Lawrence, Olga Martin, Mathias Bressel, Beverley Woon, Benjamin Blyth, Michael MacManus, Keelan Byrne, Daniel Steinfort, Tomas Kron, Gerard Hanna, David Ball, Shankar Siv. Single-arm prospective interventional study assessing feasibility of using gallium-68 ventilation and perfusion PET/CT to avoid functional lung in patients with stage III non-small cell lung cancer. BMJ open. vol 10. issue 12. 2021-05-14. PMID:33303468. |
this map of lung function can be integrated into volumetric modulated arc therapy (vmat) radiotherapy planning systems, enabling conformal avoidance of highly functioning regions of lung, thereby facilitating increased doses to tumour while reducing normal tissue doses. |
2021-05-14 |
2023-08-13 |
Not clear |
Maria Rago, Lorenzo Placidi, Mattia Polsoni, Giulia Rambaldi, Davide Cusumano, Francesca Greco, Luca Indovina, Sebastiano Menna, Elisa Placidi, Gerardina Stimato, Stefania Teodoli, Gian Carlo Mattiucci, Silvia Chiesa, Fabio Marazzi, Valeria Masiello, Vincenzo Valentini, Marco De Spirito, Luigi Azari. Evaluation of a generalized knowledge-based planning performance for VMAT irradiation of breast and locoregional lymph nodes-Internal mammary and/or supraclavicular regions. PloS one. vol 16. issue 1. 2021-05-14. PMID:33449952. |
evaluation of a generalized knowledge-based planning performance for vmat irradiation of breast and locoregional lymph nodes-internal mammary and/or supraclavicular regions. |
2021-05-14 |
2023-08-13 |
Not clear |