All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Christian Fiandra, Linda Rossi, Alessandro Alparone, Stefania Zara, Claudio Vecchi, Anna Sardo, Sara Bartoncini, Gianfranco Loi, Carla Pisani, Eva Gino, Maria Grazia Ruo Redda, Gian Marco Deotto, Paolo Tini, Stefania Comi, Dario Zerini, Gianluca Ametrano, Valentina Borzillo, Lidia Strigari, Silvia Strolin, Alessandro Savini, Antonino Romeo, Sonia Reccanello, Imad Abu Rumeileh, Nunzia Ciscognetti, Flavia Guerrisi, Gabriella Balestra, Umberto Ricardi, Ben Heijme. Automatic genetic planning for volumetric modulated arc therapy: A large multi-centre validation for prostate cancer. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 148. 2021-04-14. PMID:32361572. the first clinical genetic autoplanning algorithm (genetic planning solution, gps) was validated in ten radiotherapy centres for prostate cancer vmat by comparison with manual planning (manual). 2021-04-14 2023-08-13 Not clear
Ying Song, Junjie Hu, Yang Liu, Haiyun Hu, Yang Huang, Sen Bai, Zhang Y. Dose prediction using a deep neural network for accelerated planning of rectal cancer radiotherapy. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 149. 2021-04-14. PMID:32416279. to apply a deep neural network to predict dose distributions of rectal cancer patients for accelerated volume modulated arc technique (vmat) planning. 2021-04-14 2023-08-13 Not clear
Roya Norouzi Kandalan, Dan Nguyen, Nima Hassan Rezaeian, Ana M Barragán-Montero, Sebastiaan Breedveld, Kamesh Namuduri, Steve Jiang, Mu-Han Li. Dose prediction with deep learning for prostate cancer radiation therapy: Model adaptation to different treatment planning practices. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 153. 2021-04-14. PMID:33098927. this work aims to study the generalizability of a pre-developed deep learning (dl) dose prediction model for volumetric modulated arc therapy (vmat) for prostate cancer and to adapt the model, via transfer learning with minimal input data, to three different internal treatment planning styles and one external institution planning style. 2021-04-14 2023-08-13 Not clear
S-C Wang, J Wu, X-Q Xie, X-L Liu, Y Luo, F Wang, Z-P Li, B-L Qu, J-B Kang, D-B Wu, W-M Li, R-Y Wan. Comparison of IMRT and VMAT radiotherapy planning for Graves' ophthalmopathy based on dosimetric parameters analysis. European review for medical and pharmacological sciences. vol 24. issue 7. 2021-03-29. PMID:32329865. comparison of imrt and vmat radiotherapy planning for graves' ophthalmopathy based on dosimetric parameters analysis. 2021-03-29 2023-08-13 Not clear
Karen Lang, Brianne Loritz, Adam Schwartz, Ashley Hunzeker, Nishele Lenards, Lee Culp, Randi Finley, Kimberly S Corbi. Dosimetric comparison between volumetric-modulated arc therapy and a hybrid volumetric-modulated arc therapy and segmented field-in-field technique for postmastectomy chest wall and regional lymph node irradiation. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 45. issue 2. 2021-02-12. PMID:31570239. this hybrid technique was able to optimize tangential beams to minimize heart dose and the vmat contribution to improve dose conformity around the planning target volume (ptv). 2021-02-12 2023-08-13 Not clear
Eri Inoue, Hiroshi Doi, Hajime Monzen, Mikoto Tamura, Masahiro Inada, Kazuki Ishikawa, Kiyoshi Nakamatsu, Yasumasa Nishimur. Dose-volume Histogram Analysis of Knowledge-based Volumetric-modulated Arc Therapy Planning in Postoperative Breast Cancer Irradiation. In vivo (Athens, Greece). vol 34. issue 3. 2021-02-12. PMID:32354897. we evaluated the dosimetric profiles of manually generated volumetric-modulated arc therapy (vmat) plans and performance of a commercial knowledge-based planning system (kbp) in treating breast cancer. 2021-02-12 2023-08-13 Not clear
Rebecca Frederick, Alana Hudson, Alex Balogh, Jeffrey Q Cao, Greg Pierc. Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation. Journal of applied clinical medical physics. vol 21. issue 3. 2021-02-02. PMID:32043760. in this work, the feasibility of using flattening filter free (fff) beams in volumetric modulated arc therapy (vmat) total body irradiation (tbi) treatment planning to decrease protracted beam-on times for these treatments was investigated. 2021-02-02 2023-08-13 Not clear
Rebecca Frederick, Alana Hudson, Alex Balogh, Jeffrey Q Cao, Greg Pierc. Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation. Journal of applied clinical medical physics. vol 21. issue 3. 2021-02-02. PMID:32043760. a planning study cohort of 47 tbi patients previously treated with optimized vmat arc 6 mv beams was retrospectively examined. 2021-02-02 2023-08-13 Not clear
Rebecca Frederick, Alana Hudson, Alex Balogh, Jeffrey Q Cao, Greg Pierc. Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation. Journal of applied clinical medical physics. vol 21. issue 3. 2021-02-02. PMID:32043760. median beam-on times for the fff and clinical vmat tbi plans were 11.07 and 18.06 min, respectively, and planning time for the fff vmat tbi plans was reduced by 34.1 min. 2021-02-02 2023-08-13 Not clear
Rebecca Frederick, Alana Hudson, Alex Balogh, Jeffrey Q Cao, Greg Pierc. Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation. Journal of applied clinical medical physics. vol 21. issue 3. 2021-02-02. PMID:32043760. in conclusion, use of fff beams in vmat tbi treatment planning resulted in dose homogeneity similar to our current vmat tbi technique. 2021-02-02 2023-08-13 Not clear
Eftekhar Rajab Bolookat, Harish Malhotra, Laurie J Rich, Sandra Sexton, Leslie Curtin, Joseph A Spernyak, Anurag K Singh, Mukund Seshadr. Development and Validation of a Clinically Relevant Workflow for MR-Guided Volumetric Arc Therapy in a Rabbit Model of Head and Neck Cancer. Cancers. vol 12. issue 3. 2021-02-02. PMID:32121562. our results highlight the value of integrating mri into the workflow for vmat for improved delineation of tumor anatomy and optimal treatment planning. 2021-02-02 2023-08-13 rabbit
L Nithya, Vineeta Goel, Deepti Sharma, Karthik Vittal, Nidhi Marjar. Dosimetric Comparison of Different Planning Techniques in Left-sided Whole-Breast Irradiation: A Planning Study. Journal of medical physics. vol 45. issue 3. 2021-01-26. PMID:33487927. this planning study compared the various dosimetric parameters of different types of intensity-modulated radiotherapy (imrt) and volumetric-modulated arc therapy (vmat) techniques for left-sided breast cancer radiotherapy. 2021-01-26 2023-08-13 Not clear
Michael MacFarlane, Douglas A Hoover, Eugene Wong, Jerry J Battista, Jeff Z Che. Technical Note: A fast inverse direct aperture optimization algorithm for volumetric-modulated arc therapy. Medical physics. vol 47. issue 4. 2021-01-25. PMID:32027381. the purpose of this work is to extend and evaluate fidao for inverse planning of vmat plans. 2021-01-25 2023-08-13 Not clear
Takaaki Ito, Mikoto Tamura, Hajime Monzen, Kenji Matsumoto, Kiyoshi Nakamatsu, Tomoko Harada, Tatsuya Fuku. [Impact of Aperture Shape Controller on Knowledge-based VMAT Planning of Prostate Cancer]. Nihon Hoshasen Gijutsu Gakkai zasshi. vol 77. issue 1. 2021-01-22. PMID:33473076. [impact of aperture shape controller on knowledge-based vmat planning of prostate cancer]. 2021-01-22 2023-08-13 Not clear
Brandon Koger, Ryan Price, Da Wang, Dolla Toomeh, Sarah Geneser, Eric For. Impact of the MLC leaf-tip model in a commercial TPS: Dose calculation limitations and IROC-H phantom failures. Journal of applied clinical medical physics. vol 21. issue 2. 2021-01-20. PMID:31961036. treatment planning system (tps) dose calculation is sensitive to multileaf collimator (mlc) modeling, especially when treating with intensity-modulated radiation therapy (imrt) or vmat. 2021-01-20 2023-08-13 Not clear
Agustinus J A J van de Schoot, Wouter van den Wollenberg, Casper Carbaat, Peter de Ruiter, Marlies E Nowee, Floris Pos, Baukelien van Triest, Jan-Jakob Sonke, Tomas M Jansse. Evaluation of plan quality in radiotherapy planning with an MR-linac. Physics and imaging in radiation oncology. vol 10. 2021-01-19. PMID:33458263. our aim was to investigate the feasibility of high-quality mr-linac treatment planning for an mr-linac and to benchmark mr-linac plan quality (imrt) against current clinical practice (vmat). 2021-01-19 2023-08-13 Not clear
I Frank Ciernik, Markus Wösle, Lothar Krause, Jérôme Krayenbueh. Optimizing radiosurgery with photons for ocular melanoma. Physics and imaging in radiation oncology. vol 6. 2021-01-19. PMID:33458394. here we investigate the planning qualities of two different planning approaches, a combination of dynamic conformal arcs (dca) complemented with multiple non-coplanar static intensity-modulated (imrt) fields (dca-imrt), and volumetric modulated arc therapy (vmat) in combination with automated planning (ap). 2021-01-19 2023-08-13 Not clear
Lindsey Baker, Robert Olson, Taran Braich, Theodora Koulis, Allison Ye, Nisar Ahmed, Eric Tran, Kim Lawyer, Karl Otto, Sally Smith, Ante Mestrovic, Quinn Matthew. Real-time interactive planning for radiotherapy of head and neck cancer with volumetric modulated arc therapy. Physics and imaging in radiation oncology. vol 9. 2021-01-19. PMID:33458430. in this study we evaluated plan quality and planning efficiency using real-time interactive planning (rtip) for head and neck (hn) volumetric modulated arc therapy (vmat). 2021-01-19 2023-08-13 Not clear
Yi-Chi Liu, Hung-Ming Chang, Hsin-Hon Lin, Chia-Chun Lu, Lu-Han La. Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer. Journal of clinical medicine. vol 9. issue 12. 2020-12-26. PMID:33260404. the three planning techniques are intensity-modulated radiotherapy (imrt), volumetric modulated arc therapy (vmat; two methods) and hybrid 3d-crt/imrt (three-dimensional conformal radiotherapy/intensity-modulated radiotherapy). 2020-12-26 2023-08-13 Not clear
J Bellec, F Arab-Ceschia, J Castelli, C Lafond, E Chajo. ITV versus mid-ventilation for treatment planning in lung SBRT: a comparison of target coverage and PTV adequacy by using in-treatment 4D cone beam CT. Radiation oncology (London, England). vol 15. issue 1. 2020-12-11. PMID:32127010. the purpose of this work was to compare the actual in-treatment target coverage during volumetric modulated arctherapy (vmat) delivered through both itv-based and midv-based planning target volume (ptv) and to provide knowledge in choosing the optimal ptv for stereotactic body radiotherapy (sbrt) for lung lesions. 2020-12-11 2023-08-13 Not clear