Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Eric Simiele, Savita Dandapani, Chunhui Han, Jeffrey Wong, Susan M Hiniker, Nataliya Kovalchu. Radiation as an Immune Modulator: Where We Are With Modern Total Body Irradiation. Seminars in radiation oncology. vol 35. issue 1. 2024-12-13. PMID:39672644. |
technological advancements in radiotherapy planning and delivery are prompting a transition to modern intensity modulated techniques such as volumetric modulated arc therapy (vmat) tbi and helical tomotherapy |
2024-12-13 |
2024-12-21 |
human |
Tatsuya Kamima, Yoshihiro Ueda, Jun-Ichi Fukunaga, Yumiko Shimizu, Yasuo Yoshioka, Hajime Monze. Enhancing Estimation Accuracy of Prostate Cancer VMAT Planning: A Knowledge-based Approach Using Multiple Collimator Angles. Anticancer research. vol 44. issue 12. 2024-12-03. PMID:39626915. |
enhancing estimation accuracy of prostate cancer vmat planning: a knowledge-based approach using multiple collimator angles. |
2024-12-03 |
2024-12-06 |
Not clear |
Jin Hwa Choi, Hyejo Ryu, Do Hoon Oh, Lee Yoo, Minsoo Chu. Dosimetric advantages of dual arc increments for head and neck volumetric-modulated arc therapy in the Monaco treatment planning system. Journal of applied clinical medical physics. 2024-11-29. PMID:39611788. |
this study aimed to assess the dosimetric advantages of dual arc increments in head and neck volumetric-modulated arc therapy (vmat) in the monaco treatment planning system (tps). |
2024-11-29 |
2024-12-01 |
Not clear |
Chong Shen, Hailong Liao, Qi Wang, Hai Liu, Xiaonan Su. Effects of Inc parameter on quality of VMAT radiotherapy plans for right breast cancer based on dosimetric study. Medicine. vol 103. issue 41. 2024-10-28. PMID:39465838. |
this study aimed to investigate the influence of gantry angle increment (inc) parameters on the monaco treatment planning system for volumetric modulated arc therapy (vmat) in right breast cancer, and to determine the optimal inc parameters. |
2024-10-28 |
2024-10-30 |
Not clear |
Jiacheng Liu, Ruoxi Wang, Qingying Wang, Kaining Yao, Meijiao Wang, Yi Du, Haizhen Yue, Hao W. Replacing manual planning with automatic iterative planning for locally advanced rectal cancer VMAT treatment. Journal of applied clinical medical physics. 2024-10-15. PMID:39406255. |
replacing manual planning with automatic iterative planning for locally advanced rectal cancer vmat treatment. |
2024-10-15 |
2024-10-18 |
Not clear |
Jiacheng Liu, Ruoxi Wang, Qingying Wang, Kaining Yao, Meijiao Wang, Yi Du, Haizhen Yue, Hao W. Replacing manual planning with automatic iterative planning for locally advanced rectal cancer VMAT treatment. Journal of applied clinical medical physics. 2024-10-15. PMID:39406255. |
to develop and implement a fully automatic iterative planning (aip) system in the clinical practice, generating volumetric-modulated arc therapy plans combined with simultaneous integrated boost technique vmat (sib-vmat) for locally advanced rectal cancer (larc) patients. |
2024-10-15 |
2024-10-18 |
Not clear |
Bin Liang, Wenlong Xia, Ran Wei, Yuan Xu, Zhiqiang Liu, Jianrong Da. A deep learning-based dose calculation method for volumetric modulated arc therapy. Radiation oncology (London, England). vol 19. issue 1. 2024-10-11. PMID:39390598. |
volumetric modulated arc therapy (vmat) planning optimization involves iterative adjustment of numerous parameters, and hence requires repeatedly dose recalculation. |
2024-10-11 |
2024-10-13 |
Not clear |
Mageshraja Kannan, Sathiyan Saminathan, Varatharaj Chandraraj, B Shwetha, D Gowtham Raj, K M Ganes. Evaluation of patient-specific quality assurance for fractionated stereotactic treatment plans with 6 and 10MV photon beams in beam-matched linacs. Radiological physics and technology. 2024-10-04. PMID:39365408. |
the beam-matched la's showed good agreement between the measured and treatment planning system (tps) calculated values for fractionated stereotactic vmat plans with 6 mv and 10 mv (ff and fff) photon beams. |
2024-10-04 |
2024-10-07 |
Not clear |
Vishwadeep Mishra, Shwetima Chaudhary, Prarabdh Singh, Laxman Pandey, Archana Pandey, Rachita Chatterje. Comparing Dosimetry of Heart and Left Anterior Descending Artery Exposure in Carcinoma Esophagus Patients: Volumetric Arc Therapy Versus Intensity-Modulated Radiotherapy. Cureus. vol 16. issue 8. 2024-09-30. PMID:39347339. |
vmat planning involved a two-phase approach: 45 gy in 25 fractions followed by a boost of 5.4 gy in three fractions. |
2024-09-30 |
2024-10-02 |
Not clear |
M Zadnorouzi, S M M Abtah. Artificial intelligence (AI) applications in improvement of IMRT and VMAT radiotherapy treatment planning processes: A systematic review. Radiography (London, England : 1995). vol 30. issue 6. 2024-09-25. PMID:39321595. |
artificial intelligence (ai) applications in improvement of imrt and vmat radiotherapy treatment planning processes: a systematic review. |
2024-09-25 |
2024-09-28 |
Not clear |
Akseli Leino, Janne Heikkilä, Tuomas Virén, Juuso T J Honkanen, Jan Seppälä, Henri Korkalaine. Deep learning-based prediction of the dose-volume histograms for volumetric modulated arc therapy of left-sided breast cancer. Medical physics. 2024-09-18. PMID:39291645. |
deep learning has the potential to significantly simplify the trial-and-error process involved in inverse planning required by modern treatment techniques such as volumetric modulated arc therapy (vmat). |
2024-09-18 |
2024-09-20 |
Not clear |
Anthony Magliari, Ryan Clark, Lesley Rosa, Sushil Beriwa. HN-SIB-BPI: A single click, sub-site specific, dosimetric scorecard tuned RapidPlan model created from a foundation model for treating head and neck with bilateral neck. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-09-14. PMID:39277451. |
to develop a knowledge based planning (kbp) model for creating quantifiably high quality vmat treatment plans in a single click for head and neck cases treated simultaneous integrated boost (sib) with bilateral parotid involvement (bpi) where both parotids are near, abutting or partially overlapping target volume. |
2024-09-14 |
2024-09-18 |
Not clear |
Savino Cilla, Gabriella Macchia, Paolo Bonome, Donato Pezzulla, Carmela Romano, Mariangela Boccardi, Pietro Viola, Erika Galietta, Costanza M Donati, Alessio G Morganti, Francesco Deodat. Automated single-isocenter stereotactic body radiotherapy for multiple metastases from breast cancer: A case study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-09-12. PMID:39266381. |
sbrt with mono isocentric vmat planning represents the recommended approach to simultaneously treat multiple lesions in close proximity in the thoracic district. |
2024-09-12 |
2024-09-15 |
Not clear |
Mahmoud H Abdelgawad, Ahmed A Eldib, Tamer M Elsayed, Cm Charlie M. Investigation of the Linear accelerator low dose rate mode for pulsed low-dose-rate radiotherapy delivery. Biomedical physics & engineering express. 2024-08-27. PMID:39191263. |
all cases passed our gamma analysis with an average passing rate of 99.00% ± 0.48%.
conclusion: the study showed the applicability of planning pulsed vmat using eclipse and its successful delivery on our elekta linac. |
2024-08-27 |
2024-08-30 |
Not clear |
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. |
the aim of this work was to evaluate the conformity of intensity-modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat), and verify the accuracy of the planning and delivery system used in this work based on the aapm tg-119 protocol. |
2024-08-17 |
2024-08-20 |
Not clear |
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. |
the eclipse 13.6 treatment planning system (tps) was used to plan the tg-119 test suite, which included four test cases: multitarget, prostate, head/neck, and c-shape for imrt and vmat techniques with 6 mv and 10 mv acceleration voltages. |
2024-08-17 |
2024-08-20 |
Not clear |
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. |
the planning results showed that imrt is more conformal than vmat in certain cases. |
2024-08-17 |
2024-08-20 |
Not clear |
Tomasz Piotrowski, Adam Ryczkowski, Petros Kalendralis, Marcin Adamczewski, Piotr Sadowski, Barbara Bajon, Marta Kruszyna-Mochalska, Agata Jodd. Forecasting model for qualitative prediction of the results of patient-specific quality assurance based on planning and complexity metrics and their interrelations. Pilot study. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 29. issue 3. 2024-08-15. PMID:39144260. |
the purpose was to analyse the interrelations between planning and complexity metrics and gamma passing rates (gprs) obtained from vmat treatments and build the forecasting models for qualitative prediction (qd) of gprs results. |
2024-08-15 |
2024-08-17 |
Not clear |
Minmin Qiu, Jiajian Zhong, Zhenhua Xiao, Yongjin Den. From plan to delivery: Machine learning based positional accuracy prediction of multi-leaf collimator and estimation of delivery effect in volumetric modulated arc therapy. Journal of applied clinical medical physics. 2024-07-20. PMID:39031794. |
we comprehensively analyzed factors that may affect mlc positional accuracy in vmat, and constructed a model to predict mlc positional deviation and estimate planning delivery quality according to the vmat plans before delivery. |
2024-07-20 |
2024-07-24 |
Not clear |
Riley C Tegtmeier, Edward L Clouser, Brady S Laughlin, Diego A Santos Toesca, Mattison J Flakus, Sara Bashir, Christopher J Kutyreff, Dean Hobbis, Daniel P Harrington, Jennifer L Smetanick, Nathan Y Yu, Carlos E Vargas, Sarah E James, Jean-Claude M Rwigema, Yi Ron. Evaluation of knowledge-based planning models for male pelvic CBCT-based online adaptive radiotherapy on conventional linear accelerators. Journal of applied clinical medical physics. 2024-07-20. PMID:39031902. |
to assess the practicality of employing a commercial knowledge-based planning tool (rapidplan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (vmat) plans on iterative cone-beam computed tomography (icbct) datasets. |
2024-07-20 |
2024-07-24 |
Not clear |