All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Kai Huang, Christine Chung, Ethan B Ludmir, Lifei Zhang, Constance A Owens, Jean Gumma-De La Vega, Jack Duryea, Yao Zhao, Xinru Chen, David Fuentes, Carlos E Cardenas, Tina Marie Briere, Sam Beddar, Laurence E Court, Prajnan Da. Automatic end-to-end VMAT treatment planning for rectal cancers. Journal of applied clinical medical physics. 2024-02-06. PMID:38317597. automatic end-to-end vmat treatment planning for rectal cancers. 2024-02-06 2024-02-09 Not clear
Andreyson S Araujo, Rogério M V Silva, Divanizia N Souz. Evaluation of conventional IMRT and VMAT strategies for postmastectomy radiation therapy after immediate implant-based reconstruction using the new ESTRO-ACROP contouring guidelines. Radiation and environmental biophysics. 2024-02-01. PMID:38300284. intensity-modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat) plans generated with two different treatment planning systems (tpss, eclipse and monaco) were examined. 2024-02-01 2024-02-03 Not clear
Santa Gabriella Bonaccorsi, Thomas Tessonnier, Line Hoeltgen, Eva Meixner, Semi Harrabi, Juliane Hörner-Rieber, Thomas Haberer, Amir Abdollahi, Jürgen Debus, Andrea Mairan. Exploring Helium Ions' Potential for Post-Mastectomy Left-Sided Breast Cancer Radiotherapy. Cancers. vol 16. issue 2. 2024-01-23. PMID:38254899. an explorative treatment planning study involving ten patients, previously treated with vmat (volumetric modulated arc therapy) for 50 gy in 25 fractions for locally advanced, node-positive breast cancer, was carried out using proton pencil beam therapy with a fixed relative biological effectiveness (rbe) of 1.1 and helium therapy with a variable rbe described by the mmkm (modified microdosimetric kinetic model). 2024-01-23 2024-01-25 Not clear
Denis Panizza, Valeria Faccenda, Stefano Arcangeli, Elena De Pont. Treatment Optimization in Linac-Based SBRT for Localized Prostate Cancer: A Single-Arc versus Dual-Arc Plan Comparison. Cancers. vol 16. issue 1. 2024-01-11. PMID:38201441. moreover, the dosimetric quality and treatment efficiency of single-arc (sa) versus dual-arc (da) vmat planning and delivery approaches were compared. 2024-01-11 2024-01-13 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. dosimetric and radiobiological comparison of imrt, vmat, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. 2024-01-09 2024-01-10 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. to compare treatment planning and dosimetric outcomes for hippocampal sparing whole brain radiotherapy (wbrt) with the simultaneous integrated boost (sib) in brain metastasis (bm) patients using tumour control probability (tcp) and normal tissue complication probability (ntcp) formalism between imrt, vmat, and ht techniques. 2024-01-09 2024-01-10 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. overall, the high-quality dose distribution, tcp, and ntcp comparison between all three planning techniques show that the ht technique has better results when compared to the vmat and imrt techniques. 2024-01-09 2024-01-10 Not clear
Dominika Plaza, Łukasz Sroka, Klaudia Orzechowska, Krzysztof Ślosare. Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 28. issue 5. 2024-01-05. PMID:38179296. the aim of the study was to answer the question of whether flattening filter (ff) and flattening filter-free (fff) beams can be used alternately in the volumetric modulated arc therapy (vmat) treatment technique, regardless of the size of the irradiated volume [small (s) or large (l) planning target volume (ptv)]. 2024-01-05 2024-01-07 Not clear
Atul Mishra, Ramji Pathak, Teerth Raj Verma, Anoop Kumar Srivastava, Surendra Prasad Mishra, Kailash Kumar Mittal, Sudesh Kumar Sing. Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT: A Comparative Dosimetric Study in Lung Equivalent Heterogeneous Medium. Journal of biomedical physics & engineering. vol 13. issue 6. 2023-12-27. PMID:38148960. evaluation of radiation treatment planning algorithms in imrt and vmat: a comparative dosimetric study in lung equivalent heterogeneous medium. 2023-12-27 2023-12-29 Not clear
Anders Lideståhl, Emil Fredén, Albert Siegbahn, Gracinda Johansson, Pehr A Lin. Dosimetric Comparison of Conventional Radiotherapy, Volumetric Modulated Arc Therapy, and Proton Beam Therapy for Palliation of Thoracic Spine Metastases Secondary to Breast or Prostate Cancer. Cancers. vol 15. issue 24. 2023-12-23. PMID:38136282. the aim of this planning study was to compare the dosimetric outcomes of volumetric modulated arc therapy (vmat), proton beam therapy (pbt), and conventional external beam radiation therapy (cebrt) in the treatment of thoracic spinal metastases originating from breast or prostate cancer. 2023-12-23 2023-12-25 Not clear
Rita Alaimo, Edy Ippolito, Rita Falconi, Francesca Perrone Congedi, Cecilia Sciommari, Sonia Silipigni, Roberto Pellegrini, Alessia Carnevale, Carlo Greco, Michele Fiore, Rolando M D'Angelillo, Sara Ramell. Breast Volume Is a Predictor of Higher Heart Dose in Whole-Breast Supine Free-Breathing Volumetric-Modulated Arc Therapy Planning. Current oncology (Toronto, Ont.). vol 30. issue 12. 2023-12-22. PMID:38132402. in breast cancer volumetric-modulated arc therapy (vmat) planning, the rotation of the gantry around the target implies a greater dose spreading to the whole heart, compared to tangential-field standard treatment. 2023-12-22 2023-12-24 Not clear
Julien Darréon, Sree Bash Chandra Debnath, Mohamed Benkreira, Pierre Fau, Hugues Mailleux, Marjorie Ferré, Ahcene Benkemouche, Agnès Tallet, Pierre Annede, Claire Petit, Naji Sale. A novel lung SBRT treatment planning: Inverse VMAT plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2023-12-07. PMID:38061915. a novel lung sbrt treatment planning: inverse vmat plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target. 2023-12-07 2023-12-17 Not clear
Ignacio O Romero, Eric A Simiele, Yuliia Lozko, Yuliia Severyn, Lawrie B Skinner, Yong Yang, Jen-Yeu Wang, Lei Xing, Iris Gibbs, Susan M Hiniker, Nataliya Kovalchu. Automating the Treatment Planning Process for Volumetric Modulated Arc Therapy Craniospinal Irradiation (VMAT-CSI). Practical radiation oncology. 2023-12-04. PMID:38048988. the purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (csi) using volumetric modulated arc therapy (vmat). 2023-12-04 2023-12-10 Not clear
Jericho O'Connell, Michael David Weil, Magdalena Bazalova-Carte. Non-coplanar lung SABR treatments delivered with a gantry-mounted x-ray tube. Physics in medicine and biology. 2023-11-30. PMID:38035372. the system's non-coplanar, isocentric approach, coupled with the deep learning cbct to sct and gpu backprojection-based inverse treatment planning, offers lower maximum doses in oars and comparable conformity to vmat plans at a fraction of the cost of conventional radiotherapy. 2023-11-30 2023-12-10 Not clear
Keisuke Hamada, Toshioh Fujibuchi, Hiroyuki Arakawa, Yuichi Yokoyama, Naoki Yoshida, Hiroki Ohura, Naonobu Kunitake, Muneyuki Masuda, Takeo Honda, Satoru Tokuda, Makoto Sasak. A novel approach to predict acute radiation dermatitis in patients with head and neck cancer using a model based on Bayesian probability. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 116. 2023-11-24. PMID:38000101. in this study, we aimed to establish a method for predicting the probability of each acute radiation dermatitis (ard) grade during the head and neck volumetric modulated arc therapy (vmat) radiotherapy planning phase based on bayesian probability. 2023-11-24 2023-11-28 Not clear
Biplab Sarkar, Anirudh Pradha. Planning System-dependent Recommendations of Intensity-modulated Technique for Breast Radiotherapy: A Literature Review-based Adaptation and Institutional Dosimetric Experience from a Large-volume Tertiary Cancer Care Hospital. Journal of medical physics. vol 48. issue 3. 2023-11-16. PMID:37969141. this article aims to identify, through a literature review, the best intensity-modulated technique (imrt)/volumetric-modulated arc therapy (vmat) for the breast/chest wall (br/cw) as a function of the treatment planning system (tps) and present the institutional dosimetric data for the same. 2023-11-16 2023-11-20 Not clear
Ravindra Shende, S J Dhoble, Gourav Gupt. Dosimetric Evaluation of Radiation Treatment Planning for Simultaneous Integrated Boost Technique Using Monte Carlo Simulation. Journal of medical physics. vol 48. issue 3. 2023-11-16. PMID:37969148. all the sib plans have been generated using vmat techniques for patients with locally advanced postoperative head-and-neck squamous cell carcinoma in eclipse treatment planning system (tps) retrospectively. 2023-11-16 2023-11-20 Not clear
Kaley Woods, Zhilei Liu Shen, Zhengzheng Xu, Hualin Zhang, Yutaka Natsuaki, Karen Cheng, Vivian Li, Nathan Kim, Lijun Ma, Eric Chan. Hippocampal sparing radiation therapy for brain metastases: treatment techniques and clinical implementation. Chinese clinical oncology. vol 12. issue 5. 2023-11-15. PMID:37964545. hippocampal sparing has been demonstrated for wbrt using helical tomotherapy, static intensity-modulated radiation therapy (imrt), and volumetric-modulated arc therapy (vmat) with a variety of patient setup positions, beam arrangements, and planning parameters. 2023-11-15 2023-11-20 Not clear
Liesbeth Vandewinckele, Truus Reynders, Caroline Weltens, Frederik Maes, Wouter Crijn. Deep learning based MLC aperture and monitor unit prediction as a warm start for breast VMAT optimisation. Physics in medicine and biology. 2023-10-30. PMID:37903442. significance: vmat optimisation can be initialised by mlc apertures and mus, directly predicted from patient anatomy using a cnn, reducing planning time with more than half while maintaining clinically acceptable plans. 2023-10-30 2023-11-08 Not clear
Hui-Ling Yeh, Jia-Fu Li. The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions. Breast cancer (Dove Medical Press). vol 15. 2023-10-18. PMID:37850030. to investigate the impact of dibh for heart sparing effect on left sided breast postoperative whole breast irradiation by comparing the dosimetric characteristics of 3d-crt hybrid vmat and pure vmat treatment planning under dibh condition. 2023-10-18 2023-11-08 Not clear