All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Nicola Lambri, Giorgio Longari, Daniele Loiacono, Ricardo Coimbra Brioso, Leonardo Crespi, Carmela Galdieri, Francesca Lobefalo, Giacomo Reggiori, Roberto Rusconi, Stefano Tomatis, Luisa Bellu, Stefania Bramanti, Elena Clerici, Chiara De Philippis, Damiano Dei, Pierina Navarria, Carmelo Carlo-Stella, Ciro Franzese, Marta Scorsetti, Pietro Mancos. Deep learning-based optimization of field geometry for total marrow irradiation delivered with volumetric modulated arc therapy. Medical physics. 2024-04-18. PMID:38634859. a complex field geometry is needed to cover the large planning target volume (ptv) of tmi/tmli with volumetric modulated arc therapy (vmat). 2024-04-18 2024-04-20 Not clear
Binghao Zhang, Aaron Babier, Mark Ruschin, Timothy C Y Cha. Knowledge-based planning for Gamma Knife. Medical physics. 2024-04-10. PMID:38598107. for other treatment modalities like imrt and vmat, there has been a recent push to develop knowledge-based planning (kbp) pipelines to address the limitations presented by forward and inverse planning. 2024-04-10 2024-04-12 Not clear
Motoharu Sasaki, Yuji Nakaguchi, Takeshi Kamomae, Akira Tsuzuki, Soma Sawada, Koki Shibuya, Masataka Oita, Masahide Tominaga, Yuki Tominaga, Hitoshi Ikushim. Comparative analysis of two dose-volume histogram prediction tools for treatment planning in volumetric-modulated arc therapy: A multi-planner study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-03-31. PMID:38556402. however, a significant challenge in vmat treatment planning is the inconsistent plan quality among different planners and facilities. 2024-03-31 2024-04-03 Not clear
Tadahiro Mizoguchi, Yuji Tameshige, Tatsuya Kaneda, Yoshiji Ogawa, Yoshiyuki Muranaka, Hiroyasu Tamamur. [Estimation of Uncertainty of the VMAT Absolute Dose Measurement Due to the Phantom Setup Error Using a Treatment Planning System]. Nihon Hoshasen Gijutsu Gakkai zasshi. 2024-03-06. PMID:38447969. [estimation of uncertainty of the vmat absolute dose measurement due to the phantom setup error using a treatment planning system]. 2024-03-06 2024-03-09 Not clear
Vibhor Patodi, Tej P Soni, Dinesh K Singh, Nidhi Patni, Naresh Jakhotia, Vineeth Chittappurath, Rajkamal Kuyyanangadan, Ashna Jenny, Elumalai Kanniyappan, Anil K Gupta, Tara C Gupta, Harish Singhal, Thirumoorthy Natrajan, Farzana S Kathe. Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients. Radiation protection dosimetry. 2024-03-05. PMID:38441907. vmat plans with 6 mv photons for halcyon and clinac ix were generated and compared for each patient by dose volume histogram for planning target volume coverage and organ at risk (oar) sparing. 2024-03-05 2024-03-07 Not clear
So Hyun Park, Hyunsoo Ko, Jinhyun Cho. Effect of Jaw Tracking During Volumetric Modulated Arc Therapy for Facial Non-melanoma Skin Cancer. In vivo (Athens, Greece). vol 38. issue 2. 2024-02-28. PMID:38418154. this study aimed to analyze the dosimetric effects of jaw tracking during volumetric modulated arc therapy (vmat) planning for facial non-melanoma skin cancer (nmsc). 2024-02-28 2024-03-02 Not clear
Thomas Mann, Nicolas Ploquin, Salman Faruqi, Shaun Loewen, Kundan Thin. Stereotactic Optimized Automated Radiotherapy (SOAR): a novel automated planning solution for multi-metastatic SRS compared to HyperArc™. Biomedical physics & engineering express. 2024-02-16. PMID:38364285. this study compares a novel beam angle optimized volumetric modulated arc therapy (vmat) planning solution for multi-metastatic srs to the commercial solution hyperarc. approach: stereotactic optimized automated radiotherapy (soar) performs automated plan creation by combining collision prediction, beam angle optimization, and dose optimization to produce individualized high-quality srs plans using eclipse scripting. 2024-02-16 2024-02-19 Not clear
Kai Huang, Christine Chung, Ethan B Ludmir, Lifei Zhang, Constance A Owens, Jean Gumma-De La Vega, Jack Duryea, Yao Zhao, Xinru Chen, David Fuentes, Carlos E Cardenas, Tina Marie Briere, Sam Beddar, Laurence E Court, Prajnan Da. Automatic end-to-end VMAT treatment planning for rectal cancers. Journal of applied clinical medical physics. 2024-02-06. PMID:38317597. automatic end-to-end vmat treatment planning for rectal cancers. 2024-02-06 2024-02-09 Not clear
Andreyson S Araujo, Rogério M V Silva, Divanizia N Souz. Evaluation of conventional IMRT and VMAT strategies for postmastectomy radiation therapy after immediate implant-based reconstruction using the new ESTRO-ACROP contouring guidelines. Radiation and environmental biophysics. 2024-02-01. PMID:38300284. intensity-modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat) plans generated with two different treatment planning systems (tpss, eclipse and monaco) were examined. 2024-02-01 2024-02-03 Not clear
Santa Gabriella Bonaccorsi, Thomas Tessonnier, Line Hoeltgen, Eva Meixner, Semi Harrabi, Juliane Hörner-Rieber, Thomas Haberer, Amir Abdollahi, Jürgen Debus, Andrea Mairan. Exploring Helium Ions' Potential for Post-Mastectomy Left-Sided Breast Cancer Radiotherapy. Cancers. vol 16. issue 2. 2024-01-23. PMID:38254899. an explorative treatment planning study involving ten patients, previously treated with vmat (volumetric modulated arc therapy) for 50 gy in 25 fractions for locally advanced, node-positive breast cancer, was carried out using proton pencil beam therapy with a fixed relative biological effectiveness (rbe) of 1.1 and helium therapy with a variable rbe described by the mmkm (modified microdosimetric kinetic model). 2024-01-23 2024-01-25 Not clear
Denis Panizza, Valeria Faccenda, Stefano Arcangeli, Elena De Pont. Treatment Optimization in Linac-Based SBRT for Localized Prostate Cancer: A Single-Arc versus Dual-Arc Plan Comparison. Cancers. vol 16. issue 1. 2024-01-11. PMID:38201441. moreover, the dosimetric quality and treatment efficiency of single-arc (sa) versus dual-arc (da) vmat planning and delivery approaches were compared. 2024-01-11 2024-01-13 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. dosimetric and radiobiological comparison of imrt, vmat, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. 2024-01-09 2024-01-10 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. to compare treatment planning and dosimetric outcomes for hippocampal sparing whole brain radiotherapy (wbrt) with the simultaneous integrated boost (sib) in brain metastasis (bm) patients using tumour control probability (tcp) and normal tissue complication probability (ntcp) formalism between imrt, vmat, and ht techniques. 2024-01-09 2024-01-10 Not clear
S Balasubramanian, M K Shobana, D Anabalagan, P Thanasekar, S Joel, Prekshi Chaudhar. Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Radiation and environmental biophysics. 2024-01-09. PMID:38194100. overall, the high-quality dose distribution, tcp, and ntcp comparison between all three planning techniques show that the ht technique has better results when compared to the vmat and imrt techniques. 2024-01-09 2024-01-10 Not clear
Dominika Plaza, Łukasz Sroka, Klaudia Orzechowska, Krzysztof Ślosare. Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 28. issue 5. 2024-01-05. PMID:38179296. the aim of the study was to answer the question of whether flattening filter (ff) and flattening filter-free (fff) beams can be used alternately in the volumetric modulated arc therapy (vmat) treatment technique, regardless of the size of the irradiated volume [small (s) or large (l) planning target volume (ptv)]. 2024-01-05 2024-01-07 Not clear
Atul Mishra, Ramji Pathak, Teerth Raj Verma, Anoop Kumar Srivastava, Surendra Prasad Mishra, Kailash Kumar Mittal, Sudesh Kumar Sing. Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT: A Comparative Dosimetric Study in Lung Equivalent Heterogeneous Medium. Journal of biomedical physics & engineering. vol 13. issue 6. 2023-12-27. PMID:38148960. evaluation of radiation treatment planning algorithms in imrt and vmat: a comparative dosimetric study in lung equivalent heterogeneous medium. 2023-12-27 2023-12-29 Not clear
Anders Lideståhl, Emil Fredén, Albert Siegbahn, Gracinda Johansson, Pehr A Lin. Dosimetric Comparison of Conventional Radiotherapy, Volumetric Modulated Arc Therapy, and Proton Beam Therapy for Palliation of Thoracic Spine Metastases Secondary to Breast or Prostate Cancer. Cancers. vol 15. issue 24. 2023-12-23. PMID:38136282. the aim of this planning study was to compare the dosimetric outcomes of volumetric modulated arc therapy (vmat), proton beam therapy (pbt), and conventional external beam radiation therapy (cebrt) in the treatment of thoracic spinal metastases originating from breast or prostate cancer. 2023-12-23 2023-12-25 Not clear
Rita Alaimo, Edy Ippolito, Rita Falconi, Francesca Perrone Congedi, Cecilia Sciommari, Sonia Silipigni, Roberto Pellegrini, Alessia Carnevale, Carlo Greco, Michele Fiore, Rolando M D'Angelillo, Sara Ramell. Breast Volume Is a Predictor of Higher Heart Dose in Whole-Breast Supine Free-Breathing Volumetric-Modulated Arc Therapy Planning. Current oncology (Toronto, Ont.). vol 30. issue 12. 2023-12-22. PMID:38132402. in breast cancer volumetric-modulated arc therapy (vmat) planning, the rotation of the gantry around the target implies a greater dose spreading to the whole heart, compared to tangential-field standard treatment. 2023-12-22 2023-12-24 Not clear
Julien Darréon, Sree Bash Chandra Debnath, Mohamed Benkreira, Pierre Fau, Hugues Mailleux, Marjorie Ferré, Ahcene Benkemouche, Agnès Tallet, Pierre Annede, Claire Petit, Naji Sale. A novel lung SBRT treatment planning: Inverse VMAT plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2023-12-07. PMID:38061915. a novel lung sbrt treatment planning: inverse vmat plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target. 2023-12-07 2023-12-17 Not clear
Ignacio O Romero, Eric A Simiele, Yuliia Lozko, Yuliia Severyn, Lawrie B Skinner, Yong Yang, Jen-Yeu Wang, Lei Xing, Iris Gibbs, Susan M Hiniker, Nataliya Kovalchu. Automating the Treatment Planning Process for Volumetric Modulated Arc Therapy Craniospinal Irradiation (VMAT-CSI). Practical radiation oncology. 2023-12-04. PMID:38048988. the purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (csi) using volumetric modulated arc therapy (vmat). 2023-12-04 2023-12-10 Not clear