All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Honglai Zhang, Yijian Cao, Jeffrey Antone, Adam C Riegel, Maged Ghaly, Louis Potters, Abolghassem Jamshid. A Model-Based Method for Assessment of Salivary Gland and Planning Target Volume Dosimetry in Volumetric-Modulated Arc Therapy Planning on Head-and-Neck Cancer. Journal of medical physics. vol 44. issue 3. 2020-10-01. PMID:31576068. this study examined the relationship of achievable mean dose and percent volumetric overlap of salivary gland with the planning target volume (ptv) in volumetric-modulated arc therapy (vmat) plan in radiotherapy for a patient with head-and-neck cancer. 2020-10-01 2023-08-13 Not clear
Jianguo Shi, Fujun Yang, Xiangbai Ju, Yudong Huang, Fenge Jian. Comparative study on dosimetry of VMAT and IMRT in assisted radiotherapy after radical resection of rectal cancer. Oncology letters. vol 13. issue 5. 2020-09-30. PMID:28521403. ten cases of patients at stages ii-iii of rectal cancer transabdominal resection with postoperative pelvic radiotherapy underwent 7f-imrt and vmat radiotherapy plan design using the cms monaco treatment planning system. 2020-09-30 2023-08-13 Not clear
Jianguo Shi, Fujun Yang, Xiangbai Ju, Yudong Huang, Fenge Jian. Comparative study on dosimetry of VMAT and IMRT in assisted radiotherapy after radical resection of rectal cancer. Oncology letters. vol 13. issue 5. 2020-09-30. PMID:28521403. both plans reached up to the 95% isodose line at a volume of 100% planning target volume (ptv), the 7f- imrt plans homogeneity index (hi) was 1.0760±0.0179, and the vmat plans hi was 1.0821±0.0143. 2020-09-30 2023-08-13 Not clear
Luis Alberto Vazquez-Quino, Claudia Ivette Huerta-Hernandez, Dharanipathy Rangara. Clinical experience with machine log file software for volumetric-modulated arc therapy techniques. Proceedings (Baylor University. Medical Center). vol 30. issue 3. 2020-09-30. PMID:28670056. in this study, we compared the mobius fx with another qa option, arccheck, as well as with the treatment planning system (tps) using 30 volumetric-modulated arc therapy (vmat) plans planned and delivered on a varian truebeam linac. 2020-09-30 2023-08-13 Not clear
Yoshiko Doi, Tomoki Kimura, Takeo Nakashima, Yuki Takeuchi, Ippei Takahashi, Ikuno Nishibuchi, Yuji Murakami, Yasushi Nagat. Functional image guided radiation therapy planning in volumetric modulated arc therapy for patients with malignant pleural mesothelioma. Advances in radiation oncology. vol 2. issue 2. 2020-09-30. PMID:28740930. to investigate the incorporation of functional lung image-derived low-attenuation area (laa) based on 4-dimensional computed tomography (4d-ct) in volumetric modulated arc therapy (vmat) planning for patients with malignant pleural mesothelioma (mpm) after extrapleural pneumonectomy. 2020-09-30 2023-08-13 Not clear
Mark C Kenamond, R Alfredo Siochi, Malcolm D Matte. The dosimetric effects of limited elective nodal irradiation in volumetric modulated arc therapy treatment planning for locally advanced non-small cell lung cancer. Journal of radiation oncology. vol 7. issue 1. 2020-09-30. PMID:30220961. herein, we evaluated the dosimetric implications of the addition of limited elective nodal irradiation (leni) to standard involved field irradiation (ifi) using volumetric modulated arc therapy (vmat) planning. 2020-09-30 2023-08-13 Not clear
Christian Ostheimer, Patrick Hübsch, Martin Janich, Reinhard Gerlach, Dirk Vordermar. Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience. Radiation oncology journal. vol 34. issue 4. 2020-09-29. PMID:27951625. this consecutive treatment planning study compared imrt with volumetric-modulated arc therapy (vmat). 2020-09-29 2023-08-13 Not clear
Yu Yuan, Evan M Thomas, Grant A Clark, James M Markert, John B Fiveash, Richard A Poppl. Evaluation of multiple factors affecting normal brain dose in single-isocenter multiple target radiosurgery. Journal of radiosurgery and SBRT. vol 5. issue 2. 2020-09-29. PMID:29657894. we investigated the effects of multiple planning factors on normal brain dose for single-isocenter vmat stereotactic radiosurgery (srs). 2020-09-29 2023-08-13 Not clear
P Mohandass, D Khanna, D Manigandan, Narendra Kumar Bhalla, Abhishek Pur. Validation of a Software Upgrade in a Monte Carlo Treatment Planning System by Comparison of Plans in Different Versions. Journal of medical physics. vol 43. issue 2. 2020-09-29. PMID:29962686. validation of a new software version of a monte carlo treatment planning system through comparing plans generated by two software versions in volumetric-modulated arc therapy (vmat) for lung cancer. 2020-09-29 2023-08-13 Not clear
Wataru Takahashi, Kanabu Nawa, Akihiro Haga, Hideomi Yamashita, Toshikazu Imae, Mami Ogita, Kae Okuma, Osamu Abe, Keiichi Nakagaw. Acceptable fetal dose using flattening filter-free volumetric arc therapy (FFF VMAT) in postoperative chemoradiotherapy of tongue cancer during pregnancy. Clinical and translational radiation oncology. vol 20. 2020-09-29. PMID:31709307. prior to treatment, we compared three intensity-modulated radiation therapy (imrt) techniques, including helical tomotherapy, volumetric arc therapy (vmat), and flattening-filter free vmat (fff-vmat) using treatment planning software. 2020-09-29 2023-08-13 Not clear
David Vrána, Hana Študentová, Marcel Matzenauer, Zuzana Vlachová, Karel Cwiertka, David Gremlica, Ondřej Kalit. Treatment of brain metastases of renal cell cancer with combined hypofractionated stereotactic radiotherapy and whole brain radiotherapy with hippocampal sparing. Oncology letters. vol 11. issue 6. 2020-09-28. PMID:27313693. two single arc volumetric modulated arc radiotherapy (vmat) plans were prepared using monaco planning software. 2020-09-28 2023-08-13 Not clear
Mohandass Palanisamy, Khanna David, Manigandan Durai, Narendra Bhalla, Abhishek Pur. Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 24. issue 2. 2020-09-28. PMID:30820193. to study the dosimetric impact of statistical uncertainty (su) per plan on monte carlo (mc) calculation in monaco™ treatment planning system (tps) during volumetric modulated arc therapy (vmat) for three different clinical cases. 2020-09-28 2023-08-13 Not clear
Alejandro Prado, Ángel Gaitán, Mario Leonor, Marta Manzano, Eduardo Cabello, Raúl Díaz, Alejandro Ferrando, Ana Milanés, Gustavo Poz. Performance of the eclipse monitor unit objective tool utilizing volumetric modulated arc therapy for rectal cancer. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 24. issue 2. 2020-09-28. PMID:30858766. to assess the performance of the monitor unit (mu) objective tool in eclipse treatment planning system (tps) utilizing volumetric modulated arc therapy (vmat) for rectal cancer. 2020-09-28 2023-08-13 Not clear
Ikue Isobe, Yoshimasa Mori, Naoki Kaneda, Chisa Hashizume, Tsuneo Ishiguchi, Kojiro Suzuk. Dosimetric Comparison of Hypofractionated Multi-Beam Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy With Flattened Beam and Flattening-Filter-Free Beam for Skull Base Meningioma Adjacent to Optic Pathways. Cureus. vol 12. issue 6. 2020-09-28. PMID:32699688. materials and methods treatment planning was simulated by mb-imrt with fb and fff and by 2-rotational vmat with fb and fff in three cases of skull base meningioma [volume of the planned target volume (ptv; ptv margin=2 mm except for overlapping area with optic pathways or brainstem): 8.6 ml, 34.6 ml, and 55.3 ml respectively], which were treated previously by multi-fractionated mb-imrt [45 gy/18 fx. 2020-09-28 2023-08-13 Not clear
Maki Soyama, Rieko Azum. A New Tumor Delineation Method for Brain Metastases Radiotherapy by Jointly Referring to Contrast-Enhanced T1-Weighted and Fluid-Attenuated Inversion Recovery MRI. Cureus. vol 12. issue 7. 2020-09-28. PMID:32789051. a single-isocenter six-arc noncoplanar volumetric modulated arc radiotherapy (vmat) plan for 16 brain metastases was created by the monaco treatment planning system (elekta ab, stockholm, sweden) with a photon energy of 6 mv. 2020-09-28 2023-08-13 Not clear
Mikoto Tamura, Hajime Monzen, Kenji Matsumoto, Kazuki Kubo, Yoshihiro Ueda, Tatsuya Kamima, Masahiro Inada, Hiroshi Doi, Kiyoshi Nakamatsu, Yasumasa Nishimur. Influence of Cleaned-up Commercial Knowledge-Based Treatment Planning on Volumetric-Modulated Arc Therapy of Prostate Cancer. Journal of medical physics. vol 45. issue 2. 2020-09-28. PMID:32831489. this study aimed to investigate the influence of cleaned-up knowledge-based treatment planning (kbp) models on the plan quality for volumetric-modulated arc therapy (vmat) of prostate cancer. 2020-09-28 2023-08-13 Not clear
Emelie Adolfsson, Paulina Wesolowska, Joanna Izewska, Eva Lund, Åsa Carlsson Tedgre. END-TO-END AUDIT: COMPARISON OF TLD AND LITHIUM FORMATE EPR DOSIMETRY. Radiation protection dosimetry. vol 186. issue 1. 2020-08-04. PMID:30929009. a polystyrene phantom with a planning target volume (ptv) and an organ at risk (oar) structure was scanned using ct. a vmat dose plan was optimized to deliver 2 gy to the target volume and to minimize the dose to the oar. 2020-08-04 2023-08-13 Not clear
Se An Oh, Ji Woon Yea, Jae Won Park, Jaehyeon Par. Use of a head-tilting baseplate during volumetric-modulated arc therapy (VMAT) to better protect organs at risk in hippocampal sparing whole brain radiotherapy (HS-WBRT). PloS one. vol 15. issue 4. 2020-07-21. PMID:32348379. coplanar arcs are used with limited arc range to prevent direct beam entrance through the lens, which is challenging for satisfactory planning of hippocampal sparing in whole brain radiotherapy (hs-wbrt) with vmat. 2020-07-21 2023-08-13 Not clear
Mireille A Florijn, Abdul Wahab M Sharfo, Ruud G J Wiggenraad, Jan P C van Santvoort, Anna L Petoukhova, Mischa S Hoogeman, Mirjam E Mast, Maarten L P Dirk. Lower doses to hippocampi and other brain structures for skull-base meningiomas with intensity modulated proton therapy compared to photon therapy. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 142. 2020-07-08. PMID:31522879. this study systematically compared intensity modulated proton therapy (impt), non-coplanar volumetric modulated arc therapy (vmat) and intensity modulated radiotherapy (imrt) based on automated treatment planning. 2020-07-08 2023-08-13 Not clear
Natalie Rozanec, Zishan Allibhai, Michael Bhatti, Edwin Chan, Marlyn McIntosh, Douglas Moseley, Mojgan Taremi, Ahmar Abba. Palliation of Vertebral Metastases with Radiotherapy: Exploration of Volumetric-Modulated Arc Therapy From Development to Implementation in Routine Clinical Practice. Journal of medical imaging and radiation sciences. vol 50. issue 1. 2020-06-29. PMID:30777251. a retrospective planning analysis of 10 cases identified that utilization of vmat decreases overall planning time with a statistically significant improvement in target coverage when compared with the current conventional technique. 2020-06-29 2023-08-13 Not clear