Jacob Rembish, Pamela Myers, Daniel Saenz, Neil Kirby, Nikos Papanikolaou, Sotirios Stathaki. Effects of varying statistical uncertainty using a Monte Carlo based treatment planning system for VMAT. Journal of B.U.ON. : official journal of the Balkan Union of Oncology. vol 26. issue 4. 2021-09-26. PMID:34565034. |
to determine the severity of the effects on vmat dose calculations caused by varying statistical uncertainties (su) per control point in a monte carlo based treatment planning system (tps) and to assess the impact of the uncertainty during dose volume histogram (dvh) evaluation. |
2021-09-26 |
2023-08-13 |
Not clear |
Romena de Chavez, Garry Grogan, Ben Hug, Kate Howe, Alice Grigg, David Waterhouse, Jonathan Lane, Alan Glyde, Elizabeth Brown, Sean Bydder, David Pryor, Cathy Hargrave, Paul H Charles, James Hellyer, Martin A Eber. Assessment of HDR brachytherapy-replicating prostate radiotherapy planning for tomotherapy, cyberknife and VMAT. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2021-09-23. PMID:34551879. |
assessment of hdr brachytherapy-replicating prostate radiotherapy planning for tomotherapy, cyberknife and vmat. |
2021-09-23 |
2023-08-13 |
Not clear |
Romena de Chavez, Garry Grogan, Ben Hug, Kate Howe, Alice Grigg, David Waterhouse, Jonathan Lane, Alan Glyde, Elizabeth Brown, Sean Bydder, David Pryor, Cathy Hargrave, Paul H Charles, James Hellyer, Martin A Eber. Assessment of HDR brachytherapy-replicating prostate radiotherapy planning for tomotherapy, cyberknife and VMAT. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2021-09-23. PMID:34551879. |
planning target volume (ptv v100%), i.e., the volume of the planning target volume (ptv) receiving 100% of the relative dose, in vmat and tomotherapy sbrt plans was higher than hdr bt plans. |
2021-09-23 |
2023-08-13 |
Not clear |
Christian Harrer, Wolfgang Ullrich, Stefan Schell, Jan J Wilken. Approximation of dose quality indicator values in multi-criteria optimized (MCO) volumetric modulated arc therapy (VMAT) treatment planning using trilinear dose interpolation. Zeitschrift fur medizinische Physik. vol 30. issue 4. 2021-09-20. PMID:32576410. |
approximation of dose quality indicator values in multi-criteria optimized (mco) volumetric modulated arc therapy (vmat) treatment planning using trilinear dose interpolation. |
2021-09-20 |
2023-08-13 |
Not clear |
Christian Harrer, Wolfgang Ullrich, Stefan Schell, Jan J Wilken. Approximation of dose quality indicator values in multi-criteria optimized (MCO) volumetric modulated arc therapy (VMAT) treatment planning using trilinear dose interpolation. Zeitschrift fur medizinische Physik. vol 30. issue 4. 2021-09-20. PMID:32576410. |
to approximate dose-volume histogram (dvh) based quality indicators in volumetric modulated arc therapy (vmat) planning using multi-criteria optimization (mco) with a low number of composite optimization parameters. |
2021-09-20 |
2023-08-13 |
Not clear |
David To, Ilma Xhaferllari, Manju Liu, Jian Liang, Cory Knill, Sirisha Nandalur, Gary Gustafson, Danielle Lac. Evaluation of VMAT Planning Strategies for Prostate Patients with Bilateral Hip Prosthesis. Technology in cancer research & treatment. vol 20. 2021-09-20. PMID:34490809. |
evaluation of vmat planning strategies for prostate patients with bilateral hip prosthesis. |
2021-09-20 |
2023-08-13 |
Not clear |
E Simiele, L Skinner, Y Yang, E S Blomain, R T Hoppe, S M Hiniker, N Kovalchu. A Step Toward Making VMAT TBI More Prevalent: Automating the Treatment Planning Process. Practical radiation oncology. vol 11. issue 5. 2021-09-17. PMID:33711488. |
a step toward making vmat tbi more prevalent: automating the treatment planning process. |
2021-09-17 |
2023-08-13 |
Not clear |
E Simiele, L Skinner, Y Yang, E S Blomain, R T Hoppe, S M Hiniker, N Kovalchu. A Step Toward Making VMAT TBI More Prevalent: Automating the Treatment Planning Process. Practical radiation oncology. vol 11. issue 5. 2021-09-17. PMID:33711488. |
our purpose was to automate the treatment planning process for total body irradiation (tbi) with volumetric modulated arc therapy (vmat). |
2021-09-17 |
2023-08-13 |
Not clear |
Shohei Tanaka, Noriyuki Kadoya, Rei Umezawa, Hikaru Nemoto, Yoshiyuki Katsuta, Kengo Ito, Ken Takeda, Keiichi Jing. Evaluation of the dosimetric impact of heart function-based volumetric modulated arc therapy planning in patients with esophageal cancer. Radiological physics and technology. vol 14. issue 3. 2021-09-17. PMID:34101136. |
this study aimed to evaluate the dosimetric impact of functional avoidance planning for the myocardium with volumetric-modulated arc therapy (vmat) in patients with esophageal cancer and determine the feasibility of functional planning. |
2021-09-17 |
2023-08-13 |
Not clear |
T Kairn, S Talkhani, P H Charles, B Chua, C Y Lin, A G Livingstone, S K Maxwell, T Poroa, E Simpson-Page, E Spelleken, M Vo, S B Crow. Determining tolerance levels for quality assurance of 3D printed bolus for modulated arc radiotherapy of the nose. Physical and engineering sciences in medicine. 2021-09-16. PMID:34529247. |
film-based dose verification measurements demonstrated that both the aaa and the axb algorithms used by the varian eclipse treatment planning system (varian medical systems, palo alto, usa) were capable of providing sufficiently accurate dose calculations to allow this planning system to be used to evaluate the effects of bolus errors on dose distributions from vmat treatments of the nose. |
2021-09-16 |
2023-08-13 |
human |
Hajime Monzen, Mikoto Tamura, Yoshihiro Ueda, Jun-Ichi Fukunaga, Tatsuya Kamima, Yuta Muraki, Kazuki Kubo, Kiyoshi Nakamats. Dosimetric evaluation with knowledge-based planning created at different periods in volumetric-modulated arc therapy for prostate cancer: a multi-institution study. Radiological physics and technology. vol 13. issue 4. 2021-09-10. PMID:32986184. |
dosimetric evaluation and variation assessment were performed with two knowledge-based planning (kbp) models created at different periods for volumetric-modulated arc therapy (vmat) for prostate cancer at five institutes. |
2021-09-10 |
2023-08-13 |
Not clear |
Kenji Nakamura, Katsuya Okuhata, Mikoto Tamura, Masakazu Otsuka, Kazuki Kubo, Yoshihiro Ueda, Yasunori Nakamura, Kiyoshi Nakamatsu, Masao Tanooka, Hajime Monzen, Yasumasa Nishimur. An updating approach for knowledge-based planning models to improve plan quality and variability in volumetric-modulated arc therapy for prostate cancer. Journal of applied clinical medical physics. vol 22. issue 9. 2021-09-10. PMID:34338435. |
the purpose of this study was to compare the dose-volume parameters and regression scatter plots of the iteratively improved rapidplan (rp) models, specific knowledge-based planning (kbp) models, in volumetric-modulated arc therapy (vmat) for prostate cancer over three periods. |
2021-09-10 |
2023-08-13 |
Not clear |
Yun-Hsuan Lin, Jen-Yu Cheng, Bing-Shen Huang, Sheng-Dean Luo, Wei-Che Lin, Shang-Yu Chou, Pei-Jiuan Juang, Shen-Hao Li, Eng-Yen Huang, Yu-Ming Wan. Significant Reduction in Vertebral Artery Dose by Intensity Modulated Proton Therapy: A Pilot Study for Nasopharyngeal Carcinoma. Journal of personalized medicine. vol 11. issue 8. 2021-08-31. PMID:34442466. |
treatment planning by impt and dual-arc vmat was carried out for comparison. |
2021-08-31 |
2023-08-13 |
Not clear |
George Antoniou, Scott N Penfol. A novel TPS toolkit to assess correlation between transit fluence dosimetry and DVH metrics for adaptive head and neck radiotherapy. Physical and engineering sciences in medicine. 2021-08-31. PMID:34463949. |
planning data of eight patients that have previously undergone adaptive radiotherapy for h&n cancer using volumetric modulated arc therapy (vmat) at the royal adelaide hospital were selected for this study. |
2021-08-31 |
2023-08-13 |
Not clear |
Ghulam Murtaza, Shahid Mehmood, Maria Silvia Favretto, Stefania Cor. Optimal VMAT Delivery for Elekta MLC Beam Modulator: A Study of Collimator Rotation for Head and Neck Planning. Journal of medical imaging and radiation sciences. vol 51. issue 2. 2021-08-30. PMID:32229103. |
optimal vmat delivery for elekta mlc beam modulator: a study of collimator rotation for head and neck planning. |
2021-08-30 |
2023-08-13 |
Not clear |
Assaf Moore, Marc J Kindler, Aaron Max Alle. Use of Continuous Positive Airway Pressure (CPAP) to Limit Diaphragm Motion-A Novel Approach for Definitive Radiation Therapy for Inoperable Pleural Mesothelioma: A Pilot Study. Biology. vol 10. issue 8. 2021-08-30. PMID:34439944. |
the comparison plans among the four vmat arcs and the imrt static field treatment were able to accomplish the treatment planning objectives without significant advantages with either technique. |
2021-08-30 |
2023-08-13 |
Not clear |
Joanna Javor, Meagan Robbins, Tara Rosewall, Tim Craig, Conrad Joseph Villafuerte, Bernard Cummings, Laura Dawso. Can Conformity-Based Volumetric Modulated Arc Therapy Improve Dosimetry and Speed of Delivery in Radiation Therapy to Lumbosacral Spine Compared with Conventional Techniques? Journal of medical imaging and radiation sciences. vol 51. issue 3. 2021-08-26. PMID:32439283. |
the aim of this study was to determine if conformity-based objectives can be used to create vmat plans for lumbosacral spine palliative radiation therapy without organs at risk contours, which will improve conformity, dose homogeneity, and speed of delivery compared with standard forward planning approaches. |
2021-08-26 |
2023-08-13 |
Not clear |
Erik S Blomain, Nataliya Kovalchuk, Beth K Neilsen, Lawrie Skinner, Richard T Hoppe, Susan M Hinike. A Preliminary Report of Gonadal-Sparing TBI Using a VMAT Technique. Practical radiation oncology. vol 11. issue 2. 2021-08-18. PMID:32795616. |
planning target volume coverage was also improved for both cases with the vmat plan versus conventional 2d plan (2 gy d90% vs 1.9 gy d90%, respectively). |
2021-08-18 |
2023-08-13 |
Not clear |
Johanna Austrheim Hundvin, Kristine Fjellanger, Helge Egil Seime Pettersen, Britt Nygaard, Kari Revheim, Turid Husevåg Sulen, Christian Ekanger, Liv Bolstad Hysin. Clinical iterative model development improves knowledge-based plan quality for high-risk prostate cancer with four integrated dose levels. Acta oncologica (Stockholm, Sweden). vol 60. issue 2. 2021-08-18. PMID:33030972. |
manual volumetric modulated arc therapy (vmat) treatment planning for high-risk prostate cancer receiving whole pelvic radiotherapy (wprt) with four integrated dose levels is complex and time consuming. |
2021-08-18 |
2023-08-13 |
Not clear |
André Vinícius de Camargo, Minsong Cao, Diego da Cunha Silveira Alves da Silva, Raphael Leonardo Cunha de Araúj. Evaluation of the correlation between dosimetric, geometric, and technical parameters of radiosurgery planning for multiple brain metastases. Journal of applied clinical medical physics. vol 22. issue 8. 2021-08-17. PMID:34212482. |
to evaluate the correlation between dosimetric, geometric, and technical parameters for radiosurgery planning of multiple brain metastasis treatments treated with a linear accelerator with volumetric modulated arc therapy (vmat) technique. |
2021-08-17 |
2023-08-13 |
Not clear |