All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
W Hoegele, R Loeschel, N Merkle, P Zygmansk. An efficient inverse radiotherapy planning method for VMAT using quadratic programming optimization. Medical physics. vol 39. issue 1. 2012-04-17. PMID:22225315. an efficient inverse radiotherapy planning method for vmat using quadratic programming optimization. 2012-04-17 2023-08-12 Not clear
W Hoegele, R Loeschel, N Merkle, P Zygmansk. An efficient inverse radiotherapy planning method for VMAT using quadratic programming optimization. Medical physics. vol 39. issue 1. 2012-04-17. PMID:22225315. the purpose of this study is to investigate the feasibility of an inverse planning optimization approach for the volumetric modulated arc therapy (vmat) based on quadratic programming and the projection method. 2012-04-17 2023-08-12 Not clear
Liam Van Benthuysen, Lee Hales, Matthew B Podgorsa. Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 36. issue 4. 2012-04-05. PMID:21377864. this study aims to demonstrate that vmat is able to provide adequate organs at risk (oar) sparing and planning target volume (ptv) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. 2012-04-05 2023-08-12 Not clear
Oscar S H Chan, Michael C H Lee, Albert W M Hung, Amy T Y Chang, Rebecca M W Yeung, Anne W M Le. The superiority of hybrid-volumetric arc therapy (VMAT) technique over double arcs VMAT and 3D-conformal technique in the treatment of locally advanced non-small cell lung cancer--a planning study. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 101. issue 2. 2012-04-03. PMID:21907438. the superiority of hybrid-volumetric arc therapy (vmat) technique over double arcs vmat and 3d-conformal technique in the treatment of locally advanced non-small cell lung cancer--a planning study. 2012-04-03 2023-08-12 Not clear
Florian Stieler, Dirk Wolff, Heike Schmid, Grit Welzel, Frederik Wenz, Frank Loh. A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 101. issue 3. 2012-04-03. PMID:21962821. we compared dose distributions of vmat, step-and-shoot imrt and serial tomotherapy for typical head and neck (h&n) planning target volumes (ptv) with sparing of one parotid, a complex paradigm and a situation often encountered in h&n radiotherapy. 2012-04-03 2023-08-12 Not clear
Young K Lee, Corrinne J Brooks, James L Bedford, Alan P Warrington, Frank H Sara. Development and evaluation of multiple isocentric volumetric modulated arc therapy technique for craniospinal axis radiotherapy planning. International journal of radiation oncology, biology, physics. vol 82. issue 2. 2012-03-16. PMID:21345612. to develop and compare a volumetric modulated arc therapy (vmat) technique with conventional radiotherapy for craniospinal irradiation with respect to improved dose conformity and homogeneity in the planning target volume (ptv) and to reduced dose to organs at risk (oar). 2012-03-16 2023-08-12 Not clear
D Tatsumi, M N Hosono, R Nakada, K Ishii, S Tsutsumi, M Inoue, T Ichida, Y Mik. Direct impact analysis of multi-leaf collimator leaf position errors on dose distributions in volumetric modulated arc therapy: a pass rate calculation between measured planar doses with and without the position errors. Physics in medicine and biology. vol 56. issue 20. 2012-01-18. PMID:21965281. three different treatment planning systems (tpss) were employed to create vmat plans for five prostate cancer cases and the pass rates were compared between the tpss under various leaf position errors. 2012-01-18 2023-08-12 Not clear
Eugenio Vanetti, Giorgia Nicolini, Janne Nord, Jarkko Peltola, Alessandro Clivio, Antonella Fogliata, Luca Cozz. On the role of the optimization algorithm of RapidArc(®) volumetric modulated arc therapy on plan quality and efficiency. Medical physics. vol 38. issue 11. 2012-01-18. PMID:22047348. the rapidarc volumetric modulated arc therapy (vmat) planning process is based on a core engine, the so-called progressive resolution optimizer (pro). 2012-01-18 2023-08-12 Not clear
M Johnston, S Clifford, R Bromley, M Back, L Oliver, T Ead. Volumetric-modulated arc therapy in head and neck radiotherapy: a planning comparison using simultaneous integrated boost for nasopharynx and oropharynx carcinoma. Clinical oncology (Royal College of Radiologists (Great Britain)). vol 23. issue 8. 2011-12-22. PMID:21397477. the aim of this planning study was to evaluate vmat and dynamic intensity-modulated radiotherapy (imrt) using a simultaneous integrated boost technique 2011-12-22 2023-08-12 Not clear
M Teoh, C H Clark, K Wood, S Whitaker, A Nisbe. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. The British journal of radiology. vol 84. issue 1007. 2011-12-14. PMID:22011829. currently the majority of published data on vmat are limited to planning and feasibility studies, although there is emerging clinical outcome data in several tumour sites. 2011-12-14 2023-08-12 Not clear
M Teoh, C H Clark, K Wood, S Whitaker, A Nisbe. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. The British journal of radiology. vol 84. issue 1007. 2011-12-14. PMID:22011829. this article aims to discuss the current use of vmat techniques in practice and review the available data from planning and clinical outcome studies in various tumour sites including prostate, pelvis (lower gastrointestinal, gynaecological), head and neck, thoracic, central nervous system, breast and other tumour sites. 2011-12-14 2023-08-12 Not clear
Nicholas Hardcastle, Wolfgang A Tomé, Kerwyn Foo, Andrew Miller, Martin Carolan, Peter Metcalf. Comparison of prostate IMRT and VMAT biologically optimised treatment plans. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 36. issue 3. 2011-11-28. PMID:20801014. for 10 patients, a biologically optimized seven-field imrt plan was compared with a biologically optimized vmat plan using the same planning objectives. 2011-11-28 2023-08-12 Not clear
Juan Pardo Montero, John D Fenwic. The effect of different control point sampling sequences on convergence of VMAT inverse planning. Physics in medicine and biology. vol 56. issue 8. 2011-07-18. PMID:21444974. the effect of different control point sampling sequences on convergence of vmat inverse planning. 2011-07-18 2023-08-12 Not clear
L Masi, F Casamassima, R Doro, P Francesco. Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems. Medical physics. vol 38. issue 2. 2011-04-21. PMID:21452698. to compare and evaluate different dosimetric techniques and devices for the qa of vmat plans created by two treatment planning systems (tpss). 2011-04-21 2023-08-12 Not clear
Min Rao, Daliang Cao, Fan Chen, Jinsong Ye, Vivek Mehta, Tony Wong, David Shepar. Comparison of anatomy-based, fluence-based and aperture-based treatment planning approaches for VMAT. Physics in medicine and biology. vol 55. issue 21. 2011-01-28. PMID:20959688. comparison of anatomy-based, fluence-based and aperture-based treatment planning approaches for vmat. 2011-01-28 2023-08-12 Not clear
Min Rao, Daliang Cao, Fan Chen, Jinsong Ye, Vivek Mehta, Tony Wong, David Shepar. Comparison of anatomy-based, fluence-based and aperture-based treatment planning approaches for VMAT. Physics in medicine and biology. vol 55. issue 21. 2011-01-28. PMID:20959688. in order to take full advantage of the vmat delivery technique, one must select a robust inverse planning tool. 2011-01-28 2023-08-12 Not clear
Min Rao, Daliang Cao, Fan Chen, Jinsong Ye, Vivek Mehta, Tony Wong, David Shepar. Comparison of anatomy-based, fluence-based and aperture-based treatment planning approaches for VMAT. Physics in medicine and biology. vol 55. issue 21. 2011-01-28. PMID:20959688. the purpose of this study was to evaluate the effectiveness and efficiency of vmat planning techniques of three categories: anatomy-based, fluence-based and aperture-based inverse planning. 2011-01-28 2023-08-12 Not clear
Min Rao, Daliang Cao, Fan Chen, Jinsong Ye, Vivek Mehta, Tony Wong, David Shepar. Comparison of anatomy-based, fluence-based and aperture-based treatment planning approaches for VMAT. Physics in medicine and biology. vol 55. issue 21. 2011-01-28. PMID:20959688. for more complex hn cases, the anatomy-based approach is not able to provide clinically acceptable vmat plans while highly conformal dose distributions were obtained using both aperture-based and fluence-based inverse planning techniques. 2011-01-28 2023-08-12 Not clear
Yunzhi Ma, Daniel Chang, Paul Keall, Yiaoqin Xie, Jae-yoon Park, Tae-suk Suh, Lei Xin. Inverse planning for four-dimensional (4D) volumetric modulated arc therapy. Medical physics. vol 37. issue 11. 2011-01-13. PMID:21158274. to develop a 4d volumetric modulated arc therapy (vmat) inverse planning framework. 2011-01-13 2023-08-12 Not clear
Barbara Dobler, Karin Weidner, Oliver Koelb. Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment. Radiation oncology (London, England). vol 5. 2011-01-06. PMID:20973977. the purpose of this study was to assess plan quality and treatment time achievable with the new vmat optimization tool implemented in the treatment planning system oncentra masterplan® as compared to imrt for elekta synergys® linear accelerators. 2011-01-06 2023-08-12 Not clear