Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Caroline Lafond, Frédéric Gassa, Christophe Odin, Gaël Dréan, Justine Even, Renaud De Crevoisier, Pascal Pommier, Jean-Pierre Manens, Marie-Claude Bisto. Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 30. issue 1. 2014-09-22. PMID:23116552. |
to investigate the performances of two commercial treatment planning systems (tps) for volumetric modulated arc therapy (vmat) optimization regarding prostate cancer. |
2014-09-22 |
2023-08-12 |
Not clear |
Guishan Fu, Minghui Li, Yixin Song, Jianrong Da. A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy in nasopharyngeal carcinoma. Journal of medical physics. vol 39. issue 3. 2014-09-05. PMID:25190993. |
to explore the dosimetric effects of flattening filter-free (fff) beams in volumetric modulated arc therapy (vmat) of nasopharyngeal carcinoma via a retrospective planning study. |
2014-09-05 |
2023-08-13 |
Not clear |
Young K Lee, James L Bedford, Mary Taj, Frank H Sara. Use of volumetric-modulated arc therapy for treatment of Hodgkin lymphoma. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 4. 2014-08-22. PMID:23747222. |
the retrospective planning study showed that vmat improved ptv dose uniformity and reduced the irradiated volume of heart and lung, although the volume of lung irradiated to low doses increased. |
2014-08-22 |
2023-08-12 |
Not clear |
Yi-Chun Tsai, Chiao-Ling Tsai, Feng-Ming Hsu, Wu Jian-Kuen, Wu Chien-Jang, Jason Chia-Hsien Chen. Superior liver sparing by combined coplanar/noncoplanar volumetric-modulated arc therapy for hepatocellular carcinoma: a planning and feasibility study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 4. 2014-08-22. PMID:23769922. |
compared with step-and-shoot intensity-modulated radiotherapy (simrt) and tomotherapy, volumetric-modulated arc therapy (vmat) allows additional arc configurations in treatment planning and noncoplanar (nc) delivery. |
2014-08-22 |
2023-08-12 |
Not clear |
Yi-Chun Tsai, Chiao-Ling Tsai, Feng-Ming Hsu, Wu Jian-Kuen, Wu Chien-Jang, Jason Chia-Hsien Chen. Superior liver sparing by combined coplanar/noncoplanar volumetric-modulated arc therapy for hepatocellular carcinoma: a planning and feasibility study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 4. 2014-08-22. PMID:23769922. |
this study was first to compare vmat planning with simrt planning, and the second to evaluate the toxicity of coplanar (c)/nc-vmat treatment in patients with hepatocellular carcinoma (hcc). |
2014-08-22 |
2023-08-12 |
Not clear |
Mara W Rosenberg, Catherine M Kato, Kelly M P Carson, Nathan M Matsunaga, Robert F Arao, Emily J Doss, Charles L McCracken, Lu Z Meng, Yiyi Chen, Wolfram U Laub, Martin Fuss, James A Tany. Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: effect on target and normal-structure dose-volume metrics. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 4. 2014-08-22. PMID:23810414. |
nominal reductions of dmax and d5/d50 for the spinal cord with sectored planning did not reach statistical significance for static-gantry imrt, although vmat metrics did show a statistically significant decrease (all p < 0.001). |
2014-08-22 |
2023-08-12 |
Not clear |
John Agapit. On the possible benefits of a hybrid VMAT technique in the treatment of non-small cell lung cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 4. 2014-08-22. PMID:24094572. |
eight clinical cases already treated with crt were used for a planning study comparing target coverage and organs at risk (oar) sparing between crt and hybrid vmat (vmath). |
2014-08-22 |
2023-08-12 |
Not clear |
Dávid Papp, Jan Unkelbac. Direct leaf trajectory optimization for volumetric modulated arc therapy planning with sliding window delivery. Medical physics. vol 41. issue 1. 2014-08-19. PMID:24387493. |
the authors propose a novel optimization model for volumetric modulated arc therapy (vmat) planning that directly optimizes deliverable leaf trajectories in the treatment plan optimization problem, and eliminates the need for a separate arc-sequencing step. |
2014-08-19 |
2023-08-12 |
Not clear |
Xiang Li, Yong Yang, Tianfang Li, Kevin Fallon, Dwight E Heron, M Saiful Hu. Dosimetric effect of respiratory motion on volumetric-modulated arc therapy-based lung SBRT treatment delivered by TrueBeam machine with flattening filter-free beam. Journal of applied clinical medical physics. vol 14. issue 6. 2014-08-14. PMID:24257279. |
a two-arc vmat plan was retrospectively generated using varian's eclipse planning system for each patient. |
2014-08-14 |
2023-08-12 |
Not clear |
Xiang Li, Yong Yang, Tianfang Li, Kevin Fallon, Dwight E Heron, M Saiful Hu. Dosimetric effect of respiratory motion on volumetric-modulated arc therapy-based lung SBRT treatment delivered by TrueBeam machine with flattening filter-free beam. Journal of applied clinical medical physics. vol 14. issue 6. 2014-08-14. PMID:24257279. |
to explicitly describe the interplay effect, the contributions of each control point in the original static vmat plans to each respiratory phase were calculated, and then ten new vmat plans corresponding to different respiratory phases were generated and imported back into eclipse planning system to calculate the radiation dose based on the ct images of related respiratory phase. |
2014-08-14 |
2023-08-12 |
Not clear |
Mu-Han Lin, Robert A Price, Jinsheng Li, Shengwei Kang, Jie Li, C-M M. Investigation of pulsed IMRT and VMAT for re-irradiation treatments: dosimetric and delivery feasibilities. Physics in medicine and biology. vol 58. issue 22. 2014-06-11. PMID:24200917. |
ten-field step-and-shoot imrt and dual-arc vmat plans were generated using the eclipse tps with routine planning strategies. |
2014-06-11 |
2023-08-12 |
Not clear |
C Herbert, W Kwa, S Nakano, K James, V Moiseenko, J Wu, D Schellenberg, M Li. Stereotactic body radiotherapy: volumetric modulated arc therapy versus 3D non-coplanar conformal radiotherapy for the treatment of early stage lung cancer. Technology in cancer research & treatment. vol 12. issue 6. 2014-06-10. PMID:23617285. |
the purpose of this planning study was to compare sbrt with 3d-crt and vmat, with vmat plans generated using both single arc and 3 non-coplanar partial arcs. |
2014-06-10 |
2023-08-12 |
Not clear |
Peter W J Voet, Maarten L P Dirkx, Sebastiaan Breedveld, Abrahim Al-Mamgani, Luca Incrocci, Ben J M Heijme. Fully automated volumetric modulated arc therapy plan generation for prostate cancer patients. International journal of radiation oncology, biology, physics. vol 88. issue 5. 2014-05-19. PMID:24529714. |
to develop and evaluate fully automated volumetric modulated arc therapy (vmat) treatment planning for prostate cancer patients, avoiding manual trial-and-error tweaking of plan parameters by dosimetrists. |
2014-05-19 |
2023-08-12 |
Not clear |
Rachit Kumar, Aaron T Wild, Mark A Ziegler, Ted K Hooker, Samson D Dah, Phuoc T Tran, Jun Kang, Koren Smith, Jing Zeng, Timothy M Pawlik, Erik Tryggestad, Eric Ford, Joseph M Herma. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: a dosimetric analysis. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 3. 2014-04-24. PMID:23540490. |
dosimetric parameters for target volumes and organs at risk were compared for ds planning vs ns planning and vmat vs imrt using paired-sample wilcoxon signed rank tests. |
2014-04-24 |
2023-08-12 |
Not clear |
Rachit Kumar, Aaron T Wild, Mark A Ziegler, Ted K Hooker, Samson D Dah, Phuoc T Tran, Jun Kang, Koren Smith, Jing Zeng, Timothy M Pawlik, Erik Tryggestad, Eric Ford, Joseph M Herma. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: a dosimetric analysis. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 3. 2014-04-24. PMID:23540490. |
implementing ds constraints during sbrt planning for lapc can significantly reduce duodenal point or volumetric dose parameters for both vmat and imrt. |
2014-04-24 |
2023-08-12 |
Not clear |
Alfredo Serna, Fernando Mata, Vicente Puchade. Establishing an optimized patient-specific verification program for volumetric modulated arc therapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 3. 2014-04-24. PMID:23540493. |
planning for vmat treatments was carried out for 40 consecutive patients. |
2014-04-24 |
2023-08-12 |
Not clear |
Elizabeth Forde, Andrew Kneebone, Regina Bromley, Linxin Guo, Peter Hunt, Thomas Ead. Volumetric-modulated arc therapy in postprostatectomy radiotherapy patients: a planning comparison study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 3. 2014-04-24. PMID:23623354. |
the purpose of this study was to compare postprostatectomy planning for volumetric-modulated arc therapy (vmat) with both single arc (sa) and double arcs (da) against dynamic sliding window intensity-modulated radiotherapy (imrt). |
2014-04-24 |
2023-08-12 |
Not clear |
Malcolm D Mattes, Jennifer C Lee, Sara Elnaiem, Adel Guirguis, N C Ikoro, Hani Ashamall. A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy. Radiation oncology journal. vol 32. issue 1. 2014-04-11. PMID:24724048. |
the goal of this study is to determine whether the magnitude of overlap between planning target volume (ptv) and rectum (rectumoverlap) or ptv and bladder (bladderoverlap) in prostate cancer volumetric-modulated arc therapy (vmat) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the quantitative analyses of normal tissue effects in the clinic (quantec) dose-volume constraints are unlikely to be met. |
2014-04-11 |
2023-08-13 |
Not clear |
Grant M Clark, Richard A Popple, Brendan M Prendergast, Sharon A Spencer, Evan M Thomas, John G Stewart, Barton L Guthrie, James M Markert, John B Fiveas. Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy. Practical radiation oncology. vol 2. issue 4. 2014-03-31. PMID:24674169. |
to demonstrate plan quality and provide a practical, systematic approach to the treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy (vmat; rapidarc, varian medical systems, palo alto, ca). |
2014-03-31 |
2023-08-12 |
Not clear |
Kuan-Min Lin, John Simpson, Giuseppe Sasso, Andrea Raith, Matthias Ehrgot. Quality assessment for VMAT prostate radiotherapy planning based on data envelopment analysis. Physics in medicine and biology. vol 58. issue 16. 2014-02-20. PMID:23912157. |
quality assessment for vmat prostate radiotherapy planning based on data envelopment analysis. |
2014-02-20 |
2023-08-12 |
Not clear |