Jeremiah Wala, Ehsan Salari, Wei Chen, David Craf. Optimal partial-arcs in VMAT treatment planning. Physics in medicine and biology. vol 57. issue 18. 2013-01-28. PMID:22951381. optimal partial-arcs in vmat treatment planning. 2013-01-28 2023-08-12 Not clear
Jeremiah Wala, Ehsan Salari, Wei Chen, David Craf. Optimal partial-arcs in VMAT treatment planning. Physics in medicine and biology. vol 57. issue 18. 2013-01-28. PMID:22951381. we present a method for improving the delivery efficiency of vmat by extending the recently published vmat treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. 2013-01-28 2023-08-12 Not clear
Li Zhang, Mian Xi, Xiao-Wu Deng, Qiao-Qiao Li, Xiao-Yan Huang, Meng-Zhong Li. Four-dimensional CT-based evaluation of volumetric modulated arc therapy for abdominal lymph node metastasis from hepatocellular carcinoma. Journal of radiation research. vol 53. issue 5. 2013-01-25. PMID:22843361. this study aimed to identify the potential benefits and limitations of a new volumetric modulated arc therapy (vmat) planning system in monaco, compared with conventional intensity-modulated radiotherapy (imrt) and three-dimensional conformal radiotherapy (3dcrt). 2013-01-25 2023-08-12 Not clear
Hideharu Miura, Masayuki Fujiwara, Masao Tanooka, Hiroshi Doi, Hiroyuki Inoue, Yasuhiro Takada, Norihiko Kamikonya, Shozo Hirot. Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer. Journal of radiation research. vol 53. issue 5. 2013-01-25. PMID:22843367. plans for gantry rotation angles of 360° and 180° (full-arc and half-arc vmat) were created for six maxillary cancer cases with the monaco treatment planning system, and delivered using an elekta synergy linear accelerator. 2013-01-25 2023-08-12 Not clear
Arif N Ali, Anees H Dhabaan, Christie S Jarrio, Arsalan K Siddiqi, Jerome C Landr. Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 37. issue 3. 2013-01-15. PMID:22189026. the planning tumor volume (ptv) maximum dose (55.8 gy vs. 54.4 gy), ptv mean dose (53.9 gy vs. 52.1 gy), and conformality index (1.11 vs. 0.99) were statistically similar between the imrt and vmat plans, respectively. 2013-01-15 2023-08-12 Not clear
Rasmus Bokrant. Multicriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction. Medical physics. vol 39. issue 11. 2013-01-14. PMID:23127065. to develop a method for inverse volumetric-modulated arc therapy (vmat) planning that combines multicriteria optimization (mco) with direct machine parameter optimization. 2013-01-14 2023-08-12 Not clear
Kelly C Younge, Martha M Matuszak, Jean M Moran, Daniel L McShan, Benedick A Fraass, Donald A Robert. Penalization of aperture complexity in inversely planned volumetric modulated arc therapy. Medical physics. vol 39. issue 11. 2013-01-14. PMID:23127107. apertures obtained during volumetric modulated arc therapy (vmat) planning can be small and irregular, resulting in dosimetric inaccuracies during delivery. 2013-01-14 2023-08-12 Not clear
Per Rugaard Poulsen, Mai Lykkegaard Schmidt, Paul Keall, Esben Schjodt Worm, Walther Fledelius, Lone Hoffman. A method of dose reconstruction for moving targets compatible with dynamic treatments. Medical physics. vol 39. issue 10. 2012-12-05. PMID:23039659. to develop a method that allows a commercial treatment planning system (tps) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (imrt), volumetric arc therapy (vmat), and dynamic multileaf collimator (dmlc) tracking. 2012-12-05 2023-08-12 Not clear
Marius Treutwein, Matthias Hipp, Oliver Koelbl, Barbara Doble. Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer. Radiation oncology (London, England). vol 7. 2012-12-04. PMID:22784505. since december 2009 a new vmat planning system tool is available in oncentra masterplan v3.3 (nucletron b.v.). 2012-12-04 2023-08-12 Not clear
Tsair-Fwu Lee, Pei-Ju Chao, Hui-Min Ting, Su-Hua Lo, Yu-Wen Wang, Chiu-Ching Tuan, Fu-Min Fang, Te-Jen S. Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma. Journal of applied clinical medical physics. vol 12. issue 4. 2012-11-13. PMID:22089015. the purpose of this study was to evaluate and quantify the planning performance of smartarc-based volumetric-modulated arc radiotherapy (vmat) versus fixed-beam intensity-modulated radiotherapy (imrt) for nasopharyngeal carcinoma (npc) using a sequential mode treatment plan. 2012-11-13 2023-08-12 Not clear
Enzhuo M Quan, Joe Y Chang, Zhongxing Liao, Tingyi Xia, Zhiyong Yuan, Hui Liu, Xiaoqiang Li, Cody A Wages, Radhe Mohan, Xiaodong Zhan. Automated volumetric modulated Arc therapy treatment planning for stage III lung cancer: how does it compare with intensity-modulated radio therapy? International journal of radiation oncology, biology, physics. vol 84. issue 1. 2012-10-26. PMID:22901421. to compare the quality of volumetric modulated arc therapy (vmat) or intensity-modulated radiation therapy (imrt) plans generated by an automated inverse planning system with that of dosimetrist-generated imrt treatment plans for patients with stage iii lung cancer. 2012-10-26 2023-08-12 Not clear
Hojin Kim, Tae-Suk Suh, Rena Lee, Lei Xing, Ruijiang L. Efficient IMRT inverse planning with a new L1-solver: template for first-order conic solver. Physics in medicine and biology. vol 57. issue 13. 2012-10-25. PMID:22683930. the unique features of the approach should be particularly important in inverse planning involving a large number of beams, such as in vmat and dense angularly sampled and sparse intensity modulated radiation therapy (dassim-rt). 2012-10-25 2023-08-12 Not clear
Z van Kesteren, T M Janssen, E Damen, C van Vliet-Vroegindewei. The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts. Physics in medicine and biology. vol 57. issue 10. 2012-08-23. PMID:22516969. the dosimetric impact of leaf interdigitation and leaf width on vmat treatment planning in pinnacle: comparing pareto fronts. 2012-08-23 2023-08-12 Not clear
Simon D Fung-Kee-Fung, Rachel Hackett, Lee Hales, Graham Warren, Anurag K Sing. A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer. World journal of clinical oncology. vol 3. issue 4. 2012-08-23. PMID:22553505. to prospectively compare volumetric intensity-modulated arc therapy (vmat) and conventional intensity-modulated radiation therapy (imrt) in coverage of planning target volumes and avoidance of multiple organs at risk (oars) in patients undergoing definitive chemoradiotherapy for advanced (stage iii or iv) squamous cell cancer of the head and neck. 2012-08-23 2023-08-12 Not clear
Brandon T Nguyen, Colin Hornby, Tomas Kron, Jim Cramb, Aldo Rolfo, Daniel Pham, Annette Haworth, Keen-Hun Tai, Farshad Foroud. Optimising the dosimetric quality and efficiency of post-prostatectomy radiotherapy: a planning study comparing the performance of volumetric-modulated arc therapy (VMAT) with an optimised seven-field intensity-modulated radiotherapy (IMRT) technique. Journal of medical imaging and radiation oncology. vol 56. issue 2. 2012-08-13. PMID:22498196. optimising the dosimetric quality and efficiency of post-prostatectomy radiotherapy: a planning study comparing the performance of volumetric-modulated arc therapy (vmat) with an optimised seven-field intensity-modulated radiotherapy (imrt) technique. 2012-08-13 2023-08-12 Not clear
James L Bedford, Young K Lee, Frank H Saran, Alan P Warringto. Helical volumetric modulated arc therapy for treatment of craniospinal axis. International journal of radiation oncology, biology, physics. vol 83. issue 3. 2012-07-30. PMID:22115791. this study investigated the treatment planning and delivery of helical vmat for treatment of the craniospinal axis. 2012-07-30 2023-08-12 Not clear
David Craft, Dualta McQuaid, Jeremiah Wala, Wei Chen, Ehsan Salari, Thomas Bortfel. Multicriteria VMAT optimization. Medical physics. vol 39. issue 2. 2012-05-01. PMID:22320778. to make the planning of volumetric modulated arc therapy (vmat) faster and to explore the tradeoffs between planning objectives and delivery efficiency. 2012-05-01 2023-08-12 Not clear
Tomoki Kimura, Ikuno Nishibuchi, Yuji Murakami, Masahiro Kenjo, Yuko Kaneyasu, Yasushi Nagat. Functional image-guided radiotherapy planning in respiratory-gated intensity-modulated radiotherapy for lung cancer patients with chronic obstructive pulmonary disease. International journal of radiation oncology, biology, physics. vol 82. issue 4. 2012-04-24. PMID:22245191. to investigate the incorporation of functional lung image-derived low attenuation area (laa) based on four-dimensional computed tomography (4d-ct) into respiratory-gated intensity-modulated radiotherapy (imrt) or volumetric modulated arc therapy (vmat) in treatment planning for lung cancer patients with chronic obstructive pulmonary disease (copd). 2012-04-24 2023-08-12 Not clear
Quentin Diot, Brian Kavanagh, Robert Timmerman, Moyed Mifte. Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy. Medical physics. vol 39. issue 1. 2012-04-17. PMID:22225293. to describe biological-based optimization and monte carlo (mc) dose calculation-based treatment planning for volumetric modulated arc therapy (vmat) delivery of stereotactic body radiation therapy (sbrt) in lung, liver, and prostate patients. 2012-04-17 2023-08-12 Not clear
Murat Surucu, Mete Yeginer, Gulbin O Kavak, John Fan, James A Radosevich, Bulent Aydoga. Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom. Medical physics. vol 39. issue 1. 2012-04-17. PMID:22225298. volumetric modulated arc therapy (vmat) treatment planning studies have been reported to provide good target coverage and organs at risk (oars) sparing in total marrow irradiation (tmi). 2012-04-17 2023-08-12 Not clear