All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Ananda Giri Babu Alagar, Ganesh Kadirampatti Mani, Kaviarasu Karunakara. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry. Journal of applied clinical medical physics. vol 17. issue 1. 2016-12-13. PMID:26894345. since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (tps) should be evaluated for achieving better treatment results. 2016-12-13 2023-08-13 Not clear
Iori Sumida, Hajime Yamaguchi, Indra J Das, Hisao Kizaki, Keiko Aboshi, Mari Tsujii, Yuji Yamada, Osamu Suzuki, Yuji Seo, Fumiaki Isohashi, Kazuhiko Ogaw. Intensity-modulated radiation therapy dose verification using fluence and portal imaging device. Journal of applied clinical medical physics. vol 17. issue 1. 2016-12-13. PMID:26894363. the aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (tps) and the incident fluence deconvolved from the electronic portal imaging device (epid) images. 2016-12-13 2023-08-13 Not clear
Vijayalakshmi Kuppusamy, Vivekanandan Nagarajan, Prakash Jeevanandam, Lavanya Muruga. Comparison between In-house developed and Diamond commercial software for patient specific independent monitor unit calculation and verification with heterogeneity corrections. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 32. issue 2. 2016-12-13. PMID:26898106. in-house excel spreadsheet based monitor unit verification calculation (muvc) program and ptw's diamond secondary check software (scs), version-6 were used as a secondary check to verify the monitor unit (mu) or dose calculated by treatment planning system (tps). 2016-12-13 2023-08-13 Not clear
Vasiliki Peppa, Evaggelos Pantelis, Eleftherios Pappas, Vasileios Lahanas, Constantinos Loukas, Panagiotis Papagianni. A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy. Brachytherapy. vol 15. issue 2. 2016-11-03. PMID:26727331. to develop a user-oriented procedure for testing treatment planning system (tps) dosimetry in high-dose-rate brachytherapy, with particular focus to tpss using model-based dose calculation algorithms (mbdcas). 2016-11-03 2023-08-13 Not clear
Anthony E Millin, Rebecca S Windle, D Geraint Lewi. A comparison of electronic portal dosimetry verification methods for use in stereotactic radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 32. issue 1. 2016-11-02. PMID:26748961. the approaches examined were (a) a full monte carlo (mc) simulation of radiation transport through the linear accelerator and patient; (b) calculation of the expected fluence by a treatment planning system (tps); (c) point doses calculated along the central axis compared to doses calculated using parameters acquired using the epid. 2016-11-02 2023-08-13 Not clear
Sharon Lebron, Bo Lu, Guanghua Yan, Darren Kahler, Jonathan G Li, Brendan Barraclough, Chihray Li. Parameterization of photon beam dosimetry for a linear accelerator. Medical physics. vol 43. issue 2. 2016-10-26. PMID:26843238. in radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (tps), (2) comparing measured and tps modeled data, (3) the quality assurance process of a linear accelerator's (linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. 2016-10-26 2023-08-13 Not clear
Sandeep K Dhanesar, Tze Y Lim, Weiliang Du, Teresa L Bruno, Steven J Frank, Rajat J Kudchadke. Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699290. mim symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (tps). 2016-10-11 2023-08-13 Not clear
Sandeep K Dhanesar, Tze Y Lim, Weiliang Du, Teresa L Bruno, Steven J Frank, Rajat J Kudchadke. Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699290. we evaluated the dosimetric and planning accuracy of this new tps compared to the universally used variseed tps. 2016-10-11 2023-08-13 Not clear
Sandeep K Dhanesar, Tze Y Lim, Weiliang Du, Teresa L Bruno, Steven J Frank, Rajat J Kudchadke. Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699290. other tps tests that were done included verification of source input and geometrical accuracy, data transfer between different planning systems, text printout, 2d dose plots, dvh printout, and template grid accuracy. 2016-10-11 2023-08-13 Not clear
Suresh Rana, Yuanshui Zhen. Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699310. the main purposes of this study are to: 1) evaluate the accuracy of xio treatment planning system (tps) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (uspt); and 2) compare the dosimetric results for various dose calculation grid sizes based on real computed tomography (ct) dataset of pediatric brain cancer treatment plans generated by uspt and intensity-modulated proton therapy (impt) techniques. 2016-10-11 2023-08-13 Not clear
Shifeng Chen, Byong Yong Yi, Xiaocheng Yang, Huijun Xu, Karl L Prado, Warren D D'Souz. Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699315. unlike other commercial treatment planning systems (tps) which model the rounded leaf end differently (such as the mlc dosimetric leaf gap (dlg) or rounded leaf-tip radius), the raystation tps (raysearch laboratories, stockholm, sweden) models transmission through the rounded leaf end of the mlc with a step function, in which the radiation transmission through the leaf end is the square root of the average mlc transmission factor. 2016-10-11 2023-08-13 Not clear
Serap Çatl. High-density dental implants and radiotherapy planning: evaluation of effects on dose distribution using pencil beam convolution algorithm and Monte Carlo method. Journal of applied clinical medical physics. vol 16. issue 5. 2016-10-11. PMID:26699323. the eclipse treatment planning system (tps) couldn't precisely account for the backscatter radiation caused by the dental prostheses. 2016-10-11 2023-08-13 Not clear
Indra Yohannes, Heru Prasetio, Christoph Ber. Noncoplanar verification: a feasibility study using Philips' Pinnacle3 treatment planning system. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699558. one of the methods to verify the dose distribution from the noncoplanar fields is by comparing their planar dose distributions from the treatment planning system (tps) and the measured ones; for example, using film or electronic portal imaging devices (epid). 2016-09-28 2023-08-13 Not clear
Ji-Hye Song, Min-Joo Kim, So-Hyun Park, Seu-Ran Lee, Min-Young Lee, Dong Soo Lee, Tae Suk Su. Gamma analysis dependence on specified low-dose thresholds for VMAT QA. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699582. a total of 30 treatment plans--10 head and neck, 10 brain, and 10 prostate cancer cases--were randomly selected from the varian eclipse treatment planning system (tps). 2016-09-28 2023-08-13 Not clear
Yin Zhang, Kai Ding, Garth Cowan, Erik Tryggestad, Elwood Armour, Ken Kang-Hsin Wan. Alignment of multiradiation isocenters for megavoltage photon beam. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699586. single radiation isocenter is also commonly assumed in treatment planning systems (tps). 2016-09-28 2023-08-13 Not clear
Gangarapu Sri Krishna, Vuppu Srinivas, K M Ayyangar, Palreddy Yadagiri Redd. Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans. Journal of medical physics. vol 41. issue 3. 2016-09-21. PMID:27651566. recently, eclipse treatment planning system (tps) version 8.8 was upgraded to the latest version 13.6. 2016-09-21 2023-08-13 Not clear
Grzegorz Zwierzchowski, Grzegorz Bielęda, Janusz Skowronek, Magdalena Mazu. Film based verification of calculation algorithms used for brachytherapy planning-getting ready for upcoming challenges of MBDCA. Journal of contemporary brachytherapy. vol 8. issue 4. 2016-09-20. PMID:27648087. for the clinical use of new algorithms, it is necessary to introduce reliable and repeatable methods of treatment planning systems (tps) verification. 2016-09-20 2023-08-13 Not clear
Tarek Sahnoun, Leila Farhat, Anis Mtibaa, Mounir Besbes, Jamel Daou. Quantitative Verification of Dynamic Wedge Dose Distribution Using a 2D Ionization Chamber Array. IEEE transactions on nanobioscience. vol 14. issue 7. 2016-09-19. PMID:26441426. the accuracy of two calculation algorithms of the eclipse 8.9 treatment planning system (tps)--the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc)--in modeling the enhanced dynamic wedge (edw) was investigated. 2016-09-19 2023-08-13 Not clear
Hee Jung Kim, Siyong Kim, Yang-Kyun Park, Jung-In Kim, Jong Min Park, Sung-Joon Y. Multileaf collimator tongue-and-groove effect on depth and off-axis doses: a comparison of treatment planning data with measurements and Monte Carlo calculations. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 4. 2016-09-07. PMID:25790722. to investigate how accurately treatment planning systems (tpss) account for the tongue-and-groove (tg) effect, monte carlo (mc) simulations and radiochromic film (rcf) measurements were performed for comparison with tps results. 2016-09-07 2023-08-13 Not clear
Ghada Aldosary, Ahmad Nobah, Faisal Al-Zorkani, Slobodan Devic, Belal Mofta. A practical method of modeling a treatment couch using cone-beam computed tomography for intensity-modulated radiation therapy and RapidArc treatment delivery. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 4. 2016-09-07. PMID:25934344. although modern treatment planning systems (tps) include data for the treatment couch components, they are not manufactured identically. 2016-09-07 2023-08-13 Not clear