All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Rafael García-Mollá, Noelia de Marco-Blancas, Jorge Bonaque, Laura Vidueira, Juan López-Tarjuelo, José Perez-Calatayu. Validation of a deformable image registration produced by a commercial treatment planning system in head and neck. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 31. issue 3. 2015-12-09. PMID:25661695. in this paper we use the distances between points of interest (pois) in the computed tomography (ct) and the cone beam computed tomography (cbct) acquisition images and the inverse consistence (ic) property to validate the raystation treatment planning system (tps) dir algorithm. 2015-12-09 2023-08-13 Not clear
Luciana Batista Nogueira, Hugo Leonardo Lemos Silva, Tarcísio Passos Ribeiro de Campo. Experimental dosimetry in conformal breast teletherapy compared with the planning system. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. vol 97. 2015-11-27. PMID:25562678. conformal radiotherapy planning was elaborated in the treatment planning system (tps). 2015-11-27 2023-08-13 Not clear
Tae Seong Baek, Eun Ji Chung, Jaeman Son, Myonggeun Yoo. Feasibility study on the verification of actual beam delivery in a treatment room using EPID transit dosimetry. Radiation oncology (London, England). vol 9. 2015-10-28. PMID:25472838. the aim of this study is to evaluate the ability of transit dosimetry using commercial treatment planning system (tps) and an electronic portal imaging device (epid) with simple calibration method to verify the beam delivery based on detection of large errors in treatment room. 2015-10-28 2023-08-13 Not clear
Nazmiye Donmez Kesen, Aydin Cakir, Murat Okutan, Hatice Bilg. A comparison of TPS and different measurement techniques in small-field electron beams. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 1. 2015-10-01. PMID:25219322. all dose distribution measurements were performed using the gafchromic ebt film; these measurements were compared with data that were obtained from the computerized medical systems (cms) xio treatment planning system (tps), using the gamma-index method in the ptw verisoft software program. 2015-10-01 2023-08-13 Not clear
Marta F Dias, Marco Riboldi, Joao Seco, Inês Castelhano, Andrea Pella, Alfredo Mirandola, Luís Peralta, Mario Ciocca, Roberto Orecchia, Guido Baron. Scan path optimization with/without clustering for active beam delivery in charged particle therapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 31. issue 2. 2015-09-28. PMID:25616862. the performance was compared to simulated annealing (sa) and to commercially available treatment planning system (tps). 2015-09-28 2023-08-13 Not clear
J Gimeno, M C Pujades, T García, V Carmona, F Lliso, R Palomo, C Candela-Juan, J Richart, J Perez-Calatayu. Commissioning and initial experience with a commercial software for in vivo volumetric dosimetry. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 30. issue 8. 2015-08-24. PMID:24998334. the aim of this work is to study the differences in dose between dc and the treatment planning system (tps) to establish an accuracy level of the system. 2015-08-24 2023-08-13 Not clear
Z K Zaman, N M Ung, R A Malik, G F Ho, V C E Phua, Z Jamalludin, M T H Baharuldin, K H N. Comparison of planned and measured rectal dose in-vivo during high dose rate Cobalt-60 brachytherapy of cervical cancer. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 30. issue 8. 2015-08-24. PMID:25086486. real-time measured rectal doses were compared to calculated doses by the treatment planning system (tps). 2015-08-24 2023-08-13 Not clear
Csilla Pesznyák, Dalma Béla, Zoltán Takácsi-Nagy, Tibor Major, Csaba Polgá. [Dosimetry analysis of intensity-modulated and conformal radiation therapy for head and neck tumors]. Magyar onkologia. vol 59. issue 2. 2015-08-18. PMID:26035156. the cumulative dose was 66 gy, and the philips pinnacle3 v8.0m tps was used for treatment planning. 2015-08-18 2023-08-13 Not clear
Guangjun Li, Kui Wu, Guang Peng, Yingjie Zhang, Sen Ba. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 39. issue 4. 2015-08-13. PMID:24958705. dose distribution and isocenter point dose were evaluated by comparing the measurements and the treatment planning system (tps) calculations. 2015-08-13 2023-08-13 Not clear
Kwo-Ping Chang, Lu-Yu Chen, Yu-Huang Chie. Monte Carlo simulation of linac irradiation with dynamic wedges. Radiation protection dosimetry. vol 162. issue 1-2. 2015-07-28. PMID:25004937. these were compared with those calculated by the treatment planning system (tps) and the measured data. 2015-07-28 2023-08-13 Not clear
Chris Beltran, Yingcui Jia, Roelf Slopsema, Daniel Yeung, Zuofeng L. A simplified methodology to produce Monte Carlo dose distributions in proton therapy. Journal of applied clinical medical physics. vol 15. issue 4. 2015-07-28. PMID:25207391. the purpose of this study was to develop a simplified methodology that will produce monte carlo (mc) dose distribution for proton therapy which can be used as a clinical aid in determining the adequacy of proton plans produced from the treatment planning system (tps). 2015-07-28 2023-08-13 Not clear
Vadzim Pyshniak, Irina Fotina, Alena Zverava, Stanislau Siamkouski, Elena Zayats, Georgy Kopanitsa, Dzmitry Okuntsa. Efficiency of biological versus physical optimization for single-arc VMAT for prostate and head and neck cases. Journal of applied clinical medical physics. vol 15. issue 4. 2015-07-28. PMID:25207394. the aim of this work was to compare different approaches to vmat optimization (biological vs. physical dvh-based) in two commercial treatment planning systems (tps) for head and neck and prostate cases, using pareto fronts. 2015-07-28 2023-08-13 Not clear
Jessie Y Huang, Kiley B Pulliam, Elizabeth M McKenzie, David S Followill, Stephen F Kr. Effects of spatial resolution and noise on gamma analysis for IMRT QA. Journal of applied clinical medical physics. vol 15. issue 4. 2015-07-28. PMID:25207399. dose comparisons were performed with the treatment planning system (tps)-calculated dose as the reference, and then repeated with the film as the reference to evaluate how the choice of reference distribution affects the results of dose comparisons. 2015-07-28 2023-08-13 Not clear
Lalith K Kumaraswamy, Jonathan D Schmitt, Daniel W Bailey, Zheng Zheng Xu, Matthew B Podgorsa. Spatial variation of dosimetric leaf gap and its impact on dose delivery. Medical physics. vol 41. issue 11. 2015-07-16. PMID:25370625. during dose calculation, the eclipse treatment planning system (tps) retracts the multileaf collimator (mlc) leaf positions by half of the dosimetric leaf gap (dlg) value (measured at central axis) for all leaf positions in a dynamic mlc plan to accurately model the rounded leaf ends. 2015-07-16 2023-08-13 Not clear
S Sina, R Faghihi, A S Meigoon. A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources. Journal of biomedical physics & engineering. vol 5. issue 2. 2015-07-09. PMID:26157730. most of the current brachytherapy treatment planning systems (tps) use the tg-43u1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. 2015-07-09 2023-08-13 Not clear
Juan Agustin Calama Santiago, Miguel Angel Infante Utrilla, Maria Elisa Lavado Rodrigue. A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files. Journal of medical physics. vol 40. issue 1. 2015-07-07. PMID:26150681. from dynalog information, a file is generated with the actual multileaf collimator (mlc) positions and used as input to the treatment planning system (tps) to obtain the dynalog-derived fluence and the theoretical response over the detector array. 2015-07-07 2023-08-13 Not clear
A J Wroe, A Ghebremedhin, I R Gordon, R W Schulte, J D Slate. Water equivalent thickness analysis of immobilization devices for clinical implementation in proton therapy. Technology in cancer research & treatment. vol 13. issue 5. 2015-06-08. PMID:24000987. in order to limit additional range uncertainty, the water equivalent thickness (wet) of the immobilization device needs to be well known and accurately reflected in the calculations by the treatment planning system (tps). 2015-06-08 2023-08-12 Not clear
Anoop Haridass, Jillian Maclean, Santanu Chakraborty, John Sinclair, Janos Szanto, Daniela Iancu, Shawn Malon. Dynamic CT angiography for cyberknife radiosurgery planning of intracranial arteriovenous malformations: a technical/feasibility report. Radiology and oncology. vol 49. issue 2. 2015-06-01. PMID:26029032. successful radiosurgery for arteriovenous malformations (avms) requires accurate nidus delineation in the 3d treatment planning system (tps). 2015-06-01 2023-08-13 Not clear
Bongile Mzenda, Koki V Mugabe, Rick Sims, Guy Godwin, Dayan Lori. Modeling and dosimetric performance evaluation of the RayStation treatment planning system. Journal of applied clinical medical physics. vol 15. issue 5. 2015-05-18. PMID:25207563. the physics modeling, dose calculation accuracy and plan quality assessment of the raystation (v3.5) treatment planning system (tps) is presented in this study, with appropriate comparisons to the more established pinnacle (v9.2) tps. 2015-05-18 2023-08-13 Not clear
Christopher L Nelson, Bryan E Mason, Ronald C Robinson, Kelly D Kisling, Steven M Kirsne. Commissioning results of an automated treatment planning verification system. Journal of applied clinical medical physics. vol 15. issue 5. 2015-05-18. PMID:25207567. a dose calculation verification system (vs) was acquired and commissioned as a second check on the treatment planning system (tps). 2015-05-18 2023-08-13 Not clear