All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Atsushi Fukud. [Measurements of TMR, Absorbed Dose using Long SSD TBI Dosimetry and Calculation Accuracy of Treatment Planning System]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 29. issue 2. 2016-04-23. PMID:21979782. many techniques and prescriptions have been proposed, and the use of a treatment planning system (tps) may be best in terms of preventing toxicity to normal tissues and insufficient low dose in bone marrow. 2016-04-23 2023-08-12 Not clear
S Rana, S Pokhare. Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films. The Gulf journal of oncology. vol 1. issue 14. 2016-04-23. PMID:23996869. the development of advanced radiation treatment techniques such as intensity modulated radiation therapy (imrt) and volumetric intensity modulated arc therapy (vmat) require more accurate dose calculation algorithms within the treatment planning systems (tps) considering that the human body is composed of tissues of widely differing radiological properties and the characteristics of a therapeutic radiation treatment beam along a heterogeneous path will be different. 2016-04-23 2023-08-12 human
Wojciech Bulski, Krzysztof Chełmiński, Joanna Rostkowsk. Dosimetry audit of radiotherapy treatment planning systems. Radiation protection dosimetry. vol 165. issue 1-4. 2016-04-22. PMID:25848119. in radiotherapy treatment planning systems (tps) various calculation algorithms are used. 2016-04-22 2023-08-13 Not clear
Thiago V M Lima, Manjit Dosanjh, Alfredo Ferrari, Silvia Molineli, Mario Ciocca, Andrea Mairan. Monte Carlo Calculations Supporting Patient Plan Verification in Proton Therapy. Frontiers in oncology. vol 6. 2016-04-06. PMID:27047796. the possibility that these differences between measurement and calculated dose were related to dose modeling (treatment planning systems (tps) vs. mc), limitations on dose delivery system, or detectors mispositioning was originally explored, but other factors, such as the geometric description of the detectors, were not ruled out. 2016-04-06 2023-08-13 Not clear
Yoshinobu Shimohigashi, Fujio Araki, Masato Maruyama, Yuji Nakaguchi, Satoshi Kuwahara, Nozomu Nagasue, Yudai Ka. Evaluation of a single-scan protocol for radiochromic film dosimetry. Journal of applied clinical medical physics. vol 16. issue 2. 2016-04-05. PMID:26103194. the absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (tps) using gamma evaluation at 3% and 3 mm. 2016-04-05 2023-08-13 Not clear
Anan M Al-Karmi, Ali Asghar H Ayaz, Mamdouh S Al-Enezi, Wamied Abdel-Rahman, Nidal Dwaika. Verification of the pure alanine in PMMA tube dosimeter applicability for dosimetry of radiotherapy photon beams: a feasibility study. Australasian physical & engineering sciences in medicine. vol 38. issue 3. 2016-03-28. PMID:26138456. finally, the doses measured with alanine dosimeters were compared against the doses calculated with a commercial treatment planning system (tps). 2016-03-28 2023-08-13 Not clear
Sarah J Alnaghy, Shrikant Deshpande, Dean L Cutajar, Kemal Berk, Peter Metcalfe, Anatoly B Rosenfel. In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors. Journal of applied clinical medical physics. vol 16. issue 3. 2016-03-21. PMID:26103477. the doses at each point were measured in real time and compared to doses calculated by the treatment planning system (tps). 2016-03-21 2023-08-13 Not clear
Dewayne L Defoor, Luis A Vazquez-Quino, Panayiotis Mavroidis, Nikos Papanikolaou, Sotirios Stathaki. Anatomy-based, patient-specific VMAT QA using EPID or MLC log files. Journal of applied clinical medical physics. vol 16. issue 3. 2016-03-21. PMID:26103490. in this project, we investigated the use of an electronic portal imaging device (epid), together with the treatment planning system (tps) and mlc log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. 2016-03-21 2023-08-13 Not clear
Hanno Spreeuw, Roel Rozendaal, Priscilla Camargo, Anton Mans, Markus Wendling, Igor Olaciregui-Ruiz, Jan-Jakob Sonke, Marcel Van Herk, Ben Mijnhee. Portal dosimetry in wedged beams. Journal of applied clinical medical physics. vol 16. issue 3. 2016-03-21. PMID:26103497. this method was verified for an epid dosimetry model used for wedged beams at three photon beam energies (6, 10, and 18 mv) by comparing dose values reconstructed in a phantom with data provided by a treatment planning system (tps), as a function of field size, depth, and off-axis distance. 2016-03-21 2023-08-13 Not clear
Sarah Ghandour, Oscar Matzinger, Marc Pachou. Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer. Journal of applied clinical medical physics. vol 16. issue 3. 2016-03-21. PMID:26103500. the purpose of this work is to evaluate the volumetric-modulated arc therapy (vmat) multicriteria optimization (mco) algorithm clinically available in the raystation treatment planning system (tps) and its ability to reduce treatment planning time while providing high dosimetric plan quality. 2016-03-21 2023-08-13 Not clear
G Magro, S Molinelli, A Mairani, A Mirandola, D Panizza, S Russo, A Ferrari, F Valvo, P Fossati, M Ciocc. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation. Physics in medicine and biology. vol 60. issue 17. 2016-03-15. PMID:26301623. this study was performed to evaluate the accuracy of a commercial treatment planning system (tps), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. 2016-03-15 2023-08-13 Not clear
Leon Dunn, Joerg Lehmann, Jessica Lye, John Kenny, Tomas Kron, Andrew Alves, Andrew Cole, Jackson Zifodya, Ivan William. National dosimetric audit network finds discrepancies in AAA lung inhomogeneity corrections. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 31. issue 5. 2016-03-07. PMID:25921329. this work presents the australian clinical dosimetry service's (acds) findings of an investigation of systematic discrepancies between treatment planning system (tps) calculated and measured audit doses. 2016-03-07 2023-08-13 Not clear
Rulon Mayer, Liyong Lin, Marcus Fager, Dan Douglas, James McDonough, Alejandro Carab. Proposed linear energy transfer areal detector for protons using radiochromic film. The Review of scientific instruments. vol 86. issue 4. 2016-01-25. PMID:25933872. this study proposes the scaled-normalized difference (snd) between the treatment planning system (tps) and measured dose as the metric describing the let. 2016-01-25 2023-08-13 Not clear
Choonik Lee, Jae Won Jung, Christopher Pelletier, Anil Pyakuryal, Stephanie Lamart, Jong Oh Kim, Choonsik Le. Reconstruction of organ dose for external radiotherapy patients in retrospective epidemiologic studies. Physics in medicine and biology. vol 60. issue 6. 2015-12-24. PMID:25715852. in the current study, we developed methods to reconstruct organ doses for radiotherapy patients by using a series of computational human phantoms coupled with a commercial treatment planning system (tps) and a radiotherapy-dedicated monte carlo transport code, and performed illustrative dose calculations. 2015-12-24 2023-08-13 human
Nicolas Guevara, Ibrahim Atean, David Benoit, Yoann Pointreau, Gaëlle Angellier, Serge Marcie, Sonia Saaï, Dan Gnansia, Juliette Tharia. Effects and consequences of Digisonic SP cochlear implant on radiotherapy planning. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. vol 272. issue 7. 2015-12-15. PMID:24599596. dose attenuation was also calculated using different radiation treatment planning systems (tps) softwares and dose calculation algorithms. 2015-12-15 2023-08-12 Not clear
Jiankui Yuan, Yi Rong, Quan Che. A virtual source model for Monte Carlo simulation of helical tomotherapy. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679157. in the present work, the virtual source model (vsm) we established was based on the gold standard beam data of a tomotherapy unit, which can be exported from the treatment planning station (tps). 2015-12-15 2023-08-13 Not clear
Ying Li, Anna Rodrigues, Taoran Li, Lulin Yuan, Fang-Fang Yin, Q Jackie W. Impact of dose calculation accuracy during optimization on lung IMRT plan quality. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679172. the varian treatment planning system (tps) eclipse v11, includes an option to perform intermediate dose calculation during optimization using the aaa. 2015-12-15 2023-08-13 Not clear
Yuji Nakaguchi, Takeshi Ono, Masato Maruyama, Nozomu Nagasue, Yoshinobu Shimohigashi, Yudai Ka. Validation of fluence-based 3D IMRT dose reconstruction on a heterogeneous anthropomorphic phantom using Monte Carlo simulation. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679177. regarding the dose-volume histograms, there were no large differences between mc, analytical anisotropic algorithm (aaa) in eclipse treatment planning system (tps), 3dvh, and the compass system. 2015-12-15 2023-08-13 Not clear
Eduardo S Moura, John A Micka, Cliff G Hammer, Wesley S Culberson, Larry A DeWerd, Maria Elisa C M Rostelato, Carlos A Zeitun. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms. Medical physics. vol 42. issue 4. 2015-12-15. PMID:25832047. this work presents the development of a phantom to verify the treatment planning system (tps) algorithms used for high-dose-rate (hdr) brachytherapy. 2015-12-15 2023-08-13 Not clear
Zhao Xie, Jinyou Hu, Lian Zou, Weisha Zhang, Yuxin Zou, Kelin Luo, Xiangxiang Liu, Luxin Y. [Development of a Software for Automatically Generated Contours in Eclipse TPS]. Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation. vol 39. issue 3. 2015-12-15. PMID:26524794. the automatic generation of planning targets and auxiliary contours have achieved in eclipse tps 11.0. 2015-12-15 2023-08-13 Not clear