Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Marija Majer, Liliana Stolarczyk, Marijke De Saint-Hubert, Damian Kabat, Željka Kneževic, Saveta Miljanic, Natalia Mojzeszek, Roger Harriso. OUT-OF-FIELD DOSE MEASUREMENTS FOR 3D CONFORMAL AND INTENSITY MODULATED RADIOTHERAPY OF A PAEDIATRIC BRAIN TUMOUR. Radiation protection dosimetry. vol 176. issue 3. 2018-04-16. PMID:28338841. |
comparison of measured doses and doses calculated by the treatment planning system (tps) showed that the tps underestimated out-of-field doses both for imrt and 3d crt. |
2018-04-16 |
2023-08-13 |
Not clear |
Miaoyun Huang, David Huang, Jianping Zhang, Yuangui Chen, Benhua Xu, Lixin Che. Preliminary study of clinical application on IMRT three-dimensional dose verification-based EPID system. Journal of applied clinical medical physics. vol 18. issue 4. 2018-04-02. PMID:28594085. |
the gamma passing rates of the 3d dose verification-based epid system (edose, version 3.01, raydose, guangdong, china) and delta4 measurements were then compared with treatment planning system (tps) calculations using global gamma criteria of 5%/3 mm, 3%/3 mm, and 2%/2 mm. |
2018-04-02 |
2023-08-13 |
Not clear |
Stephen J Gardner, Siming Lu, Chang Liu, Ning Wen, Indrin J Chett. Tuning of AcurosXB source size setting for small intracranial targets. Journal of applied clinical medical physics. vol 18. issue 3. 2018-03-30. PMID:28470819. |
this study details a method to evaluate the source size selection for small field intracranial stereotactic radiosurgery (srs) deliveries in eclipse treatment planning system (tps) for acurosxb dose calculation algorithm. |
2018-03-30 |
2023-08-13 |
Not clear |
Sankar Arumugam, Megan Berry, Cesar Ochoa, Aitang Xing, Bradley Beeksma, Philip Via. Dose discrepancy between planning system estimation and measurement in spine stereotactic body radiation therapy: A case report. Journal of medical imaging and radiation oncology. vol 61. issue 5. 2018-03-13. PMID:28477339. |
a dual arc volumetric modulated arc therapy plan was generated on the pinnacle treatment planning system (tps) with a 6 mv elekta machine using gantry control point spacing of 4°. |
2018-03-13 |
2023-08-13 |
Not clear |
Wook-Geun Shin, Mauro Testa, Hak Soo Kim, Jong Hwi Jeong, Se Byeong Lee, Yeon-Joo Kim, Chul Hee Mi. Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea. Physics in medicine and biology. vol 62. issue 19. 2018-03-12. PMID:28809759. |
the developed system was validated by comparing the dose distributions with those calculated by the treatment planning system (tps) for a lung phantom and two patient cases of abdomen and internal mammary node. |
2018-03-12 |
2023-08-13 |
Not clear |
Hugh Stephen Leff, Clifton M Chow, Stephen C Grave. No Magic Bullet: A Theory-Based Meta-Analysis of Markov Transition Probabilities in Studies of Service Systems for Persons With Mental Disabilities. Psychiatric services (Washington, D.C.). vol 68. issue 3. 2018-02-22. PMID:27745533. |
a random-effects meta-analysis of studies that used markov transition probabilities (tps) to describe outcomes for mental health service systems of differing quality for persons with serious mental illness was implemented to improve the scientific understanding of systems performance, to use in planning simulations to project service system costs and outcomes over time, and to test a theory of how outcomes for systems varying in quality differ. |
2018-02-22 |
2023-08-13 |
Not clear |
Syed Bilal Ahmad, Moti Raj Paudel, Arman Sarfehnia, Anthony Kim, Geordi Pang, Mark Ruschin, Arjun Sahgal, Brian M Kelle. The dosimetric impact of gadolinium-based contrast media in GBM brain patient plans for a MRI-Linac. Physics in medicine and biology. vol 62. issue 16. 2018-02-15. PMID:28635617. |
dosimetric effects of gadolinium based contrast media (gadovist) were evaluated for the elekta mri linear accelerator using the research version of the monaco treatment planning system (tps). |
2018-02-15 |
2023-08-13 |
Not clear |
Victor Hernandez, Juan Antonio Vera-Sánchez, Laure Vieillevigne, Jordi Sae. Commissioning of the tongue-and-groove modelling in treatment planning systems: from static fields to VMAT treatments. Physics in medicine and biology. vol 62. issue 16. 2018-02-15. PMID:28639942. |
adequate modelling of the multi-leaf collimator (mlc) by treatment planning systems (tps) is essential for accurate dose calculations in intensity-modulated radiation-therapy. |
2018-02-15 |
2023-08-13 |
Not clear |
Yusuke Tsuruta, Mitsuhiro Nakamura, Yuki Miyabe, Manabu Nakata, Yoshitomo Ishihara, Nobutaka Mukumoto, Mami Akimoto, Tomohiro Ono, Shinsuke Yano, Kyoji Higashimura, Yukinori Matsuo, Takashi Mizowaki, Masahiro Hiraok. Use of a second-dose calculation algorithm to check dosimetric parameters for the dose distribution of a first-dose calculation algorithm for lung SBRT plans. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 44. 2018-01-30. PMID:28760507. |
to verify lung stereotactic body radiotherapy (sbrt) plans using a secondary treatment planning system (tps) as an independent method of verification and to define tolerance levels (tls) in lung sbrt between the primary and secondary tpss. |
2018-01-30 |
2023-08-13 |
Not clear |
Assi Valve, Jani Keyriläinen, Jarmo Kulmal. Compass model-based quality assurance for stereotactic VMAT treatment plans. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 44. 2018-01-30. PMID:29254590. |
to use compass as a model-based quality assurance (qa) tool for stereotactic body radiation therapy (sbrt) and stereotactic radiation therapy (srt) volumetric modulated arc therapy (vmat) treatment plans calculated with eclipse treatment planning system (tps). |
2018-01-30 |
2023-08-13 |
Not clear |
P Lonski, S Keehan, S Siva, D Pham, R D Franich, M L Taylor, T Kro. Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 37. 2018-01-16. PMID:28535921. |
to assess out-of-field dose using three different variants of lif thermoluminescence dosimeters (tld) for ten patients who underwent stereotactic ablative body radiotherapy (sabr) for primary renal cell carcinoma (rcc) and compare with treatment planning system (tps) dose calculations. |
2018-01-16 |
2023-08-13 |
Not clear |
Marijke De Saint-Hubert, Dirk Verellen, Kenneth Poels, Wouter Crijns, Federica Magliona, Tom Depuydt, Filip Vanhavere, Lara Struelen. Out-of-field doses from pediatric craniospinal irradiations using 3D-CRT, IMRT, helical tomotherapy and electron-based therapy. Physics in medicine and biology. vol 62. issue 13. 2017-12-25. PMID:28398210. |
additionally, the study evaluates and explores tools for calculating out-of-field patient doses using the treatment planning system (tps) and analytical models. |
2017-12-25 |
2023-08-13 |
Not clear |
Anton Mans, Danny Schuring, Mark P Arends, Cornelia A J M Vugts, Jochem W H Wolthaus, Heidi T Lotz, Marjan Admiraal, Rob J W Louwe, Michel C Öllers, Jeroen B van de Kame. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy. Physics in medicine and biology. vol 61. issue 19. 2017-11-16. PMID:27649474. |
after describing the transition from imrt to vmat, the paper addresses machine quality assurance (qa) and treatment planning system (tps) commissioning for vmat. |
2017-11-16 |
2023-08-13 |
Not clear |
David J Eaton, Kevin Alt. Dependence of volume calculation and margin growth accuracy on treatment planning systems for stereotactic radiosurgery. The British journal of radiology. vol 90. issue 1080. 2017-11-09. PMID:29022748. |
uncertainties in radiotherapy target structures are partly dependent on differences between volume calculation and margin growing methods in treatment planning systems (tps). |
2017-11-09 |
2023-08-13 |
Not clear |
P M McCowan, G Asuni, T van Beek, E van Uytven, K Kujanpaa, B M C McCurd. A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID. Physics in medicine and biology. vol 62. issue 4. 2017-10-24. PMID:28079525. |
validation was carried out using 24 sbrt-vmat patient plans by comparing: (1) ion chamber point dose measurements in a solid water phantom, (2) the treatment planning system (tps) predicted 3d dose to the epid reconstructed 3d dose in a solid water phantom, and (3) the tps predicted 3d dose to the epid and our forward predicted reconstructed 3d dose in the patient (ct data). |
2017-10-24 |
2023-08-13 |
Not clear |
Makoto Sakama, Nobuyuki Kanematsu, Taku Inaniw. A robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning. Physics in medicine and biology. vol 61. issue 15. 2017-10-19. PMID:27426737. |
the dose warping method is based on the nominal dose distribution and the water-equivalent path length obtained from planning computed tomography data with a clinically commissioned treatment planning system (tps). |
2017-10-19 |
2023-08-13 |
Not clear |
G Magro, T J Dahle, S Molinelli, M Ciocca, P Fossati, A Ferrari, T Inaniwa, N Matsufuji, K S Ytre-Hauge, A Mairan. The FLUKA Monte Carlo code coupled with the NIRS approach for clinical dose calculations in carbon ion therapy. Physics in medicine and biology. vol 62. issue 9. 2017-10-17. PMID:28252446. |
particle therapy facilities often require monte carlo (mc) simulations to overcome intrinsic limitations of analytical treatment planning systems (tps) related to the description of the mixed radiation field and beam interaction with tissue inhomogeneities. |
2017-10-17 |
2023-08-13 |
Not clear |
M Marafini, L Gasparini, R Mirabelli, D Pinci, V Patera, A Sciubba, E Spiriti, D Stoppa, G Traini, A Sart. MONDO: a neutron tracker for particle therapy secondary emission characterisation. Physics in medicine and biology. vol 62. issue 8. 2017-10-03. PMID:28350543. |
since neutrons can release a significant dose far away from the tumour region, precise measurements of their flux, production energy and angle distributions are eagerly sought in order to improve the treatment planning system (tps) software. |
2017-10-03 |
2023-08-13 |
Not clear |
Anna Zawadzka, Marta Nesteruk, Beata Brzozowska, Paweł F Kukołowic. Method of predicting the mean lung dose based on a patient׳s anatomy and dose-volume histograms. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 1. 2017-09-28. PMID:28237293. |
for each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (tps) was calculated. |
2017-09-28 |
2023-08-13 |
Not clear |
Dustin J Jacqmin, Jeremy S Bredfeldt, Sean P Frigo, Jennifer B Smilowit. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams". Journal of applied clinical medical physics. vol 18. issue 1. 2017-09-26. PMID:28291929. |
the validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (tps). |
2017-09-26 |
2023-08-13 |
Not clear |