Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
James R Kerns, David S Followill, Jessica Lowenstein, Andrea Molineu, Paola Alvarez, Paige A Taylor, Stephen F Kr. Reference dosimetry data and modeling challenges for Elekta accelerators based on IROC-Houston site visit data. Medical physics. vol 45. issue 5. 2018-08-23. PMID:29537634. |
reference dosimetry data can provide an independent second check of acquired values when commissioning or validating a treatment planning system (tps). |
2018-08-23 |
2023-08-13 |
Not clear |
Nathan Cho, Panagiotis Tsiamas, Esteban Velarde, Erik Tryggestad, Robert Jacques, Ross Berbeco, Todd McNutt, Peter Kazanzides, John Won. Validation of GPU-accelerated superposition-convolution dose computations for the Small Animal Radiation Research Platform. Medical physics. vol 45. issue 5. 2018-08-23. PMID:29542820. |
the graphics processing unit (gpu)-accelerated superposition-convolution (sc) method for dose computation has been integrated into the treatment planning system (tps) for sarrp. |
2018-08-23 |
2023-08-13 |
Not clear |
Shinichi Nakayama, Hajime Monzen, Yuichi Onishi, Soichiro Kaneshige, Ikuo Kann. Estimation of extremely small field radiation dose for brain stereotactic radiotherapy using the Vero4DRT system. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 50. 2018-08-23. PMID:29891094. |
the purpose of this study was a dosimetric validation of the vero4drt for brain stereotactic radiotherapy (srt) with extremely small fields calculated by the treatment planning system (tps) iplan (ver.4.5.1; algorithm xvmc). |
2018-08-23 |
2023-08-13 |
Not clear |
Frank M Gagliardi, Liam Day, Christopher M Poole, Rick D Franich, Moshi Ges. Water equivalent PRESAGE Medical physics. vol 45. issue 3. 2018-08-20. PMID:29314051. |
the patient treatment planning systems (tps) developed for these treatments use simulated data of the synchrotron x-ray beam to produce the dosimetry in the treatment plan. |
2018-08-20 |
2023-08-13 |
Not clear |
S Deshpande, S J Blake, A Xing, P E Metcalfe, L C Holloway, P Via. A simple model for transit dosimetry based on a water equivalent EPID. Medical physics. vol 45. issue 3. 2018-08-20. PMID:29314080. |
the aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (we-epid) and a conventional treatment planning system (tps). |
2018-08-20 |
2023-08-13 |
Not clear |
Ruohui Zhang, Yulan Gao, Wenwen Ba. Quantification and comparison the dosimetric impact of two treatment couch model in VMAT. Journal of applied clinical medical physics. vol 19. issue 1. 2018-08-17. PMID:29094802. |
the use of monte carlo treatment planning systems (tps) in radiation therapy has increased the dosimetric accuracy of vmat treatment sequences. |
2018-08-17 |
2023-08-13 |
Not clear |
Huagang Yan, Fanqing Guo, Dengsong Zhu, Stefan Stryker, Sharron Trumpore, Kenneth Roberts, Susan Higgins, Ravinder Nath, Zhe Chen, Wu Li. On the use of bolus for pacemaker dose measurement and reduction in radiation therapy. Journal of applied clinical medical physics. vol 19. issue 1. 2018-08-17. PMID:29152840. |
in general, the treatment planning system (tps) calculation underestimated the dose to cied, but it predicts the cied dose more accurately when bolus is used. |
2018-08-17 |
2023-08-13 |
Not clear |
Ulrich W Langner, Michelle Mundis, Dan Strauss, Mingyao Zhu, Sina Mossaheb. A comparison of two pencil beam scanning treatment planning systems for proton therapy. Journal of applied clinical medical physics. vol 19. issue 1. 2018-08-17. PMID:29205763. |
analytical dose calculation algorithms for eclipse and raystation treatment planning systems (tps), as well as a raystation monte carlo model are compared to corresponding measured point doses. |
2018-08-17 |
2023-08-13 |
Not clear |
Xiadong Li, Lu Wang, Jiahao Wang, Xu Han, Bing Xia, Shixiu Wu, Weigang H. Dosimetric benefits of automation in the treatment of lower thoracic esophageal cancer: Is manual planning still an alternative option? Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 4. 2018-08-08. PMID:28754289. |
thirty patients with lower thoracic ec were randomly selected for replanning vmat plans using auto-planning in pinnacle treatment planning system (tps) version 9.10. |
2018-08-08 |
2023-08-13 |
Not clear |
Xiaoning Ding, Wei Liu, Jiajian Shen, Aman Anand, Joshua B Stoker, Yanle Hu, Martin Bue. Use of a radial projection to reduce the statistical uncertainty of spot lateral profiles generated by Monte Carlo simulation. Journal of applied clinical medical physics. vol 18. issue 6. 2018-07-31. PMID:28921881. |
monte carlo (mc) simulation has been used to generate commissioning data for the beam modeling of treatment planning system (tps). |
2018-07-31 |
2023-08-13 |
Not clear |
L Irazola, J A Terrón, B Sánchez-Nieto, B Roberto, F Sánchez-Doblad. Peripheral equivalent neutron dose model implementation for radiotherapy patients. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 42. 2018-07-30. PMID:28372877. |
this work aims to improve an existing methodology for adult patient pnd estimations to generalize it to young and children, for its implementation in treatment planning systems (tps). |
2018-07-30 |
2023-08-13 |
Not clear |
Juliana Fernandes Pavoni, Wellington Furtado Pimenta Neves-Junior, Matheus Antonio da Silveira, Cecília Maria Kalil Haddad, Oswaldo Baff. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique. Medical physics. vol 44. issue 9. 2018-07-25. PMID:28594461. |
the evaluation is based on the comparison of the results obtained with the composite phantom with the treatment planning system (tps) dose distribution validated by using the clinical conventional quality control with point and planar dose measurements. |
2018-07-25 |
2023-08-13 |
Not clear |
Amy Wexler, Bruce Gu, Sreekrishna Goddu, Maya Mutic, Sridhar Yaddanapudi, Lindsey Olsen, Taylor Harry, Camille Noel, Todd Pawlicki, Sasa Mutic, Bin Ca. FMEA of manual and automated methods for commissioning a radiotherapy treatment planning system. Medical physics. vol 44. issue 9. 2018-07-23. PMID:28419482. |
to evaluate the level of risk involved in treatment planning system (tps) commissioning using a manual test procedure, and to compare the associated process-based risk to that of an automated commissioning process (acp) by performing an in-depth failure modes and effects analysis (fmea). |
2018-07-23 |
2023-08-13 |
Not clear |
C Bäumer, D Geismar, B Koska, P H Kramer, J Lambert, M Lemke, S Plaude, L Pschichholz, S Qamhiyeh, A Schiemann, B Timmermann, X Vermere. Comprehensive clinical commissioning and validation of the RayStation treatment planning system for proton therapy with active scanning and passive treatment techniques. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 43. 2018-07-18. PMID:29195558. |
to commission the treatment planning system (tps) raystation for proton therapy including beam models for spot scanning and for uniform scanning. |
2018-07-18 |
2023-08-13 |
Not clear |
Yaping Qi, Lijuan He, Zhi Wang, Yuanyuan Liu, Hongdong Liu, Wanli Huo, X George Xu, Zhi Che. EVALUATION OF SECONDARY DOSE AND CANCER RISK FOR OUT-OF-FIELD ORGAN IN ESOPHAGEAL CANCER IMRT IN A CHINESE HOSPITAL USING ATOM PHANTOM MEASUREMENTS. Radiation protection dosimetry. vol 177. issue 4. 2018-07-02. PMID:28472430. |
when compared with the calculation results by the pinnacle treatment planning system (tps), most of the out-of-field organ doses were underestimated in the tps and the percentage of underestimation reached 100% for distant organs such as the bladder, prostate and testis. |
2018-07-02 |
2023-08-13 |
Not clear |
Dae-Hyun Kim, Sungkoo Cho, Kwanghyun Jo, EunHyuk Shin, Chae-Seon Hong, Youngyih Han, Tae-Suk Suh, Do Hoon Lim, Doo Ho Cho. Proton range verification in inhomogeneous tissue: Treatment planning system vs. measurement vs. Monte Carlo simulation. PloS one. vol 13. issue 3. 2018-06-25. PMID:29505589. |
from this perspective, the treatment planning system (tps) must be accurate. |
2018-06-25 |
2023-08-13 |
Not clear |
Makoto Hirata, Hajime Monzen, Kohei Hanaoka, Yasumasa Nishimur. MEASUREMENT OF ABSORPTION DOSE OUTSIDE IRRADIATION FIELD IN IMRT. Radiation protection dosimetry. vol 176. issue 4. 2018-05-29. PMID:28338869. |
the absorption dose outside the irradiation field for prostate intensity-modulated radiation therapy was measured and evaluated by comparison with calculated values of radiation treatment planning system (tps). |
2018-05-29 |
2023-08-13 |
Not clear |
Makoto Hirata, Hajime Monzen, Kohei Hanaoka, Yasumasa Nishimur. MEASUREMENT OF ABSORPTION DOSE OUTSIDE IRRADIATION FIELD IN IMRT. Radiation protection dosimetry. vol 176. issue 4. 2018-05-29. PMID:28338869. |
the values of tps calculated were using varian clinac21ex/eclipse and tomotherapy planning system for constant irradiation time. |
2018-05-29 |
2023-08-13 |
Not clear |
Makoto Hirata, Hajime Monzen, Kohei Hanaoka, Yasumasa Nishimur. MEASUREMENT OF ABSORPTION DOSE OUTSIDE IRRADIATION FIELD IN IMRT. Radiation protection dosimetry. vol 176. issue 4. 2018-05-29. PMID:28338869. |
the calculated values of tps, varian clinac21ex/eclipse and tomotherapy planning system were calculated, up to 17 and 55 cm from the isocenter, respectively. |
2018-05-29 |
2023-08-13 |
Not clear |
Peng Du, Yueyong Xiao, Wei L. Modified Fan-Shaped Distribution Technology for Computed Tomography (CT)-Guided Radioactive Seed Implantation in Lung Cancer Patients with Lung Dysfunction. Medical science monitor : international medical journal of experimental and clinical research. vol 23. 2018-05-25. PMID:28889144. |
the brachytherapy planning system (tps) was used to draw up a preoperative seed implantation plan. |
2018-05-25 |
2023-08-13 |
Not clear |