All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Akari Kaneko, Iori Sumida, Hirokazu Mizuno, Fumiaki Isohashi, Osamu Suzuki, Yuji Seo, Keisuke Otani, Keisuke Tamari, Kazuhiko Ogaw. Comparison of gamma index based on dosimetric error and clinically relevant dose-volume index based on three-dimensional dose prediction in breast intensity-modulated radiation therapy. Radiation oncology (London, England). vol 14. issue 1. 2019-04-01. PMID:30808377. although the treatment planning system (tps) uses sophisticated algorithm to calculate the dose distribution, the calculation accuracy depends on the particular tps used. 2019-04-01 2023-08-13 Not clear
Josephine Chen, Olivier Morin, Brandon Weethee, Angelica Perez-Andujar, Justin Phillips, Mareike Held, Vasant Kearney, Dae Yup Han, Joey Cheung, Cynthia Chuang, Gilmer Valdes, Atchar Sudhyadhom, Timothy Solber. Optimizing beam models for dosimetric accuracy over a wide range of treatments. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 58. 2019-03-25. PMID:30824149. using this method, a truebeam stx machine with high definition multi-leaf collimators (mlcs) was commissioned in the raystation treatment planning system (tps). 2019-03-25 2023-08-13 Not clear
Marco Esposito, Andrea Bruschi, Paolo Bastiani, Alessandro Ghirelli, Silvia Pini, Serenella Russo, Giovanna Zatell. Characterization of EPID software for VMAT transit dosimetry. Australasian physical & engineering sciences in medicine. vol 41. issue 4. 2019-03-18. PMID:30341673. the volumetric gamma agreement index 3%/3 mm between twenty vmat dose distributions reconstructed by dc and calculated with treatment planning system (tps) were compared to those obtained using ptw octavius®4d to assess dc accuracy in vmat quality assurance (qa). 2019-03-18 2023-08-13 Not clear
Sheng Huang, Minglei Kang, Kevin Souris, Christopher Ainsley, Timothy D Solberg, James E McDonough, Charles B Simone, Liyong Li. Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy. Journal of applied clinical medical physics. vol 19. issue 5. 2019-03-07. PMID:30058170. the purpose of this paper is to present a methodology for commissioning and validating an accurate mc code for pbs utilizing a parameterized source model, including an implementation of a range shifter, that can independently check the adc in commercial treatment planning system (tps) and fast monte carlo dose calculation in opensource platform (mcsquare). 2019-03-07 2023-08-13 Not clear
Grace E A Healy, Steven H Marsh, Andrew T Cousin. The dosimetric effect of electron density overrides in 3DCRT Lung SBRT for a range of lung tumor dimensions. Journal of applied clinical medical physics. vol 19. issue 6. 2019-03-06. PMID:30199127. the itv plans showed the highest gamma pass rate agreement between treatment planning system (tps) and measured dose (p < 0.040). 2019-03-06 2023-08-13 Not clear
An Qin, David Gersten, Jian Liang, Qiang Liu, Inga Grill, Thomas Guerrero, Craig Stevens, Di Ya. A clinical 3D/4D CBCT-based treatment dose monitoring system. Journal of applied clinical medical physics. vol 19. issue 6. 2019-03-06. PMID:30306710. this system integrates with our treatment planning system (tps), linacs recording and verification system (r&v), and cbct imaging system, consisting of three modules: treatment schedule monitoring module (tsm), pseudo-ct generating module (pcg), and treatment dose reconstruction/evaluation module (tdr). 2019-03-06 2023-08-13 Not clear
Mohammad Taghi Bahreyni Toossi, Shokouhozaman Soleymanifard, Bagher Farhood, Ashraf Farkhari, Courtney Knau. Evaluation of electron dose calculations accuracy of a treatment planning system in radiotherapy of breast cancer with photon-electron technique. Journal of cancer research and therapeutics. vol 14. issue Supplement. 2019-03-06. PMID:30539854. the aim of this study was to assess the accuracy of electron dose calculations of prowess panther treatment planning system (tps) for abutting photon-electron (pe) technique. 2019-03-06 2023-08-13 Not clear
b' Hans-Erik K\\xc3\\xa4llman, Erik Traneus, Anders Ahnesj\\xc3\\xb. Toward automated and personalized organ dose determination in CT examinations - A comparison of two tissue characterization models for Monte Carlo organ dose calculation with a Therapy Planning System. Medical physics. vol 46. issue 2. 2019-02-28. PMID:30582891.' to facilitate individualized organ dose estimates, we explore the possibility to automate organ dose calculations using a radiotherapy treatment planning system (tps). 2019-02-28 2023-08-13 Not clear
Pasquale Tamborra, Erica Martinucci, Raffaella Massafra, Marco Bettiol, Caterina Capomolla, Annarita Zagari, Vittorio Didonn. The 3D isodose structure-based method for clinical dose distributions comparison in pretreatment patient-QA. Medical physics. vol 46. issue 2. 2019-02-25. PMID:30450559. currently, the method adopted to compare the measured dose distribution with the treatment planning system tps calculated dose distribution is gamma analysis. 2019-02-25 2023-08-13 Not clear
Pablo Yepes, Antony Adair, David Grosshans, Dragan Mirkovic, Falk Poenisch, Uwe Titt, Qianxia Wang, Radhe Moha. Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy. Physics in medicine and biology. vol 63. issue 4. 2019-02-11. PMID:29339570. to evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (tps) on dosimetric indices in intensity modulated proton therapy. 2019-02-11 2023-08-13 Not clear
Jose A Baeza, Cecile J A Wolfs, Sebastiaan M J J G Nijsten, Frank Verhaege. Validation and uncertainty analysis of a pre-treatment 2D dose prediction model. Physics in medicine and biology. vol 63. issue 3. 2019-01-28. PMID:29176074. the model was validated against a treatment planning system (tps; eclipse) and radiochromic film measurements for complex clinical scenarios, including volumetric modulated arc therapy (vmat). 2019-01-28 2023-08-13 Not clear
H Prasetio, J Wölfelschneider, M Ziegler, M Serpa, B Witulla, C Ber. Dose calculation and verification of the Vero gimbal tracking treatment delivery. Physics in medicine and biology. vol 63. issue 3. 2019-01-28. PMID:29311415. however, the availability of treatment planning systems (tps) to simulate dtt is limited. 2019-01-28 2023-08-13 Not clear
Li Chen, Botian Huang, Xiaoyan Huang, Wufei Cao, Wenzhao Sun, Xiaowu Den. Clinical evaluation for the difference of absorbed doses calculated to medium and calculated to water by Monte Carlo method. Radiation oncology (London, England). vol 13. issue 1. 2019-01-28. PMID:30055661. to evaluate the difference of absorbed doses calculated to medium and to water by a monte carlo (mc) algorithm based treatment planning system (tps), and to assess the potential clinical impact to dose prescription. 2019-01-28 2023-08-13 Not clear
Robin De Roover, Wouter Crijns, Kenneth Poels, Steven Michiels, An Nulens, Bianca Vanstraelen, Saskia Petillion, Marisol De Brabandere, Karin Haustermans, Tom Depuyd. Validation and IMRT/VMAT delivery quality of a preconfigured fast-rotating O-ring linac system. Medical physics. vol 46. issue 1. 2019-01-21. PMID:30417523. a fast-rotating o-ring dedicated intensity modulated radiotherapy (imrt)/volumetric modulated arc therapy (vmat) delivery system, the halcyon, is delivered by default with a fully preconfigured photon beam model in the treatment planning system (tps). 2019-01-21 2023-08-13 Not clear
Chih-Yuan Lin, An-Cheng Shiau, Jin-Huei Ji, Chia-Jung Lee, Ti-Hao Wang, Shu-Hui Hsu, Ji-An Lian. A simple method for determining dosimetric leaf gap with cross-field dose width for rounded leaf-end multileaf collimator systems. Radiation oncology (London, England). vol 13. issue 1. 2019-01-04. PMID:30424789. the dosimetric leaf gap (dlg) and multileaf collimator (mlc) transmission are two important systematic parameters used to model the rounded mlc leaf ends effect when commissioning an eclipse treatment planning system (tps). 2019-01-04 2023-08-13 Not clear
Kathryn Masi, Paul Archer, William Jackson, Yilun Sun, Matthew Schipper, Daniel Hamstra, Martha Matusza. Knowledge-based treatment planning and its potential role in the transition between treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 43. issue 3. 2018-11-19. PMID:29174796. commissioning a new treatment planning system (tps) involves many time-consuming tasks. 2018-11-19 2023-08-13 Not clear
Kathryn Masi, Paul Archer, William Jackson, Yilun Sun, Matthew Schipper, Daniel Hamstra, Martha Matusza. Knowledge-based treatment planning and its potential role in the transition between treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 43. issue 3. 2018-11-19. PMID:29174796. we investigated the role that knowledge-based planning (kbp) can play in aiding a clinic's transition to a new tps. 2018-11-19 2023-08-13 Not clear
Golshan Mahmoudi, Bagher Farhood, Parvaneh Shokrani, Alireza Amouheidari, Maryam Ataro. Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma. Journal of cancer research and therapeutics. vol 14. issue 5. 2018-11-02. PMID:30197343. these may influence the dose calculation accuracy, calculated by treatment planning systems (tps). 2018-11-02 2023-08-13 Not clear
Mohammad Taghi Bahreyni Toossi, Shokouhozaman Soleymanifard, Bagher Farhood, Shokoufeh Mohebbi, David Davenpor. Assessment of accuracy of out-of-field dose calculations by TiGRT treatment planning system in radiotherapy. Journal of cancer research and therapeutics. vol 14. issue 3. 2018-11-01. PMID:29893331. the objective was to quantify the accuracy of dose calculation for out-of-field regions by the commercially available tigrt version 1.2 (linatech, sunnyvale, ca, usa) treatment planning system (tps) for a clinical treatment delivered on a siemens primus with the single energy of 6 mv. 2018-11-01 2023-08-13 Not clear
R Chakarova, R Cronholm, M Krantz, P Andersson, A Hallqvis. An automated Monte Carlo QC system for volumetric modulated arc therapy: Possibilities and challenges. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 51. 2018-10-29. PMID:29572112. to develop and implement an automated monte carlo (mc) system for patient specific vmat quality control in a patient geometry that generates treatment planning system (tps) compliant dicom objects and includes a module for 3d analysis of dose deviations. 2018-10-29 2023-08-13 Not clear