Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Takanori Matsuoka, Fujio Araki, Takeshi Ohno, Junichi Sakata, Hirofumi Tominag. Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 3. 2020-02-10. PMID:30455092. |
vmat-sbrt plans for peripheral lung tumors were created using the eclipse treatment planning system (tps) for 24 patients with nonsmall cell lung cancer. |
2020-02-10 |
2023-08-13 |
Not clear |
Wataru Okada, Masao Tanooka, Keisuke Sano, Mayuri Shibata, Hiroshi Doi, Masayoshi Miyazaki, Ryuta Nakahara, Masaki Sueoka, Hitomi Suzuki, Masayuki Fujiwara, Taisuke Inomata, Koichiro Yamakad. Couch modeling optimization for tomotherapy planning and delivery. Journal of applied clinical medical physics. vol 20. issue 8. 2020-02-07. PMID:31343831. |
based on ionization chamber measurements, we performed interactive optimization and determined the most appropriate physical density of these virtual structures in a treatment planning system (tps). |
2020-02-07 |
2023-08-13 |
Not clear |
Livia Marrazzo, Icro Meattini, Chiara Arilli, Silvia Calusi, Marta Casati, Cinzia Talamonti, Lorenzo Livi, Stefania Pallott. Auto-planning for VMAT accelerated partial breast irradiation. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 132. 2020-01-28. PMID:30825975. |
to evaluate the quality of accelerated partial breast irradiation (apbi) plans generated by the auto-planning module of a commercial treatment planning system (tps). |
2020-01-28 |
2023-08-13 |
Not clear |
Suresh Rana, E James Jebaseelan Samue. Measurements of in-air spot size of pencil proton beam for various air gaps in conjunction with a range shifter on a ProteusPLUS PBS dedicated machine and comparison to the proton dose calculation algorithms. Australasian physical & engineering sciences in medicine. vol 42. issue 3. 2020-01-21. PMID:31222565. |
the purpose of this study is to (i) investigate the impact of various air gaps in conjunction with a range shifter of 7.5 cm water-equivalent-thickness (wet) on in-air spot size of a pencil proton beam at the isocenter and off-axis points, and (ii) compare the treatment planning system (tps) calculated spot sizes against the measured spot sizes. |
2020-01-21 |
2023-08-13 |
Not clear |
Takahiro Kato, Kazuhiro Arai, Tatsuhiko Sagara, Ryohei Kato, Yuhei Yamazaki, Sho Oyam. Patient-specific quality assurance for proton depth dose distribution using a multi-layer ionization chamber in a single-ring wobbling method. Radiological physics and technology. vol 12. issue 3. 2020-01-21. PMID:31273670. |
the depth dose distributions measured using zebra are compared with those calculated using the treatment planning system (tps), xio-m, and measured using an ionization chamber with a motorized water phantom system. |
2020-01-21 |
2023-08-13 |
Not clear |
Yongdong Zhuang, Yinghui Li, Jinhan Zhu, Lixin Chen, Xiaowei Li. A trial for EBT3 film without batch-specific calibration using a neural network. Physics in medicine and biology. vol 64. issue 5. 2020-01-01. PMID:30625437. |
the calculated dose map of tps (radiation therapy planning system) was used as a label (the desired output) for the ann model. |
2020-01-01 |
2023-08-13 |
Not clear |
Jia-Cheng Lee, Keh-Shih Chuang, Yen-Wan Hsueh Liu, Tzung-Yi Lin, Yi-Chiao Teng, Ling-Wei Wan. A comparison of dose distributions in gross tumor volume between boron neutron capture therapy alone and combined boron neutron capture therapy plus intensity modulation radiation therapy for head and neck cancer. PloS one. vol 14. issue 4. 2019-12-31. PMID:30947267. |
nine patients with recurrent head and neck (h&n) cancer received boron neutron capture therapy (bnct) in one fraction at the tsing-hua open pool reactor (thor) utilizing the thorplan treatment planning system (tps). |
2019-12-31 |
2023-08-13 |
Not clear |
Alexandra Bourgouin, Nicolas Varfalvy, Louis Archambaul. Thermoplastic wrapped lead sheet to reduce cardiac device cumulative dose. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:29598925. |
psd measurements were compared with dose calculation from the treatment planning system (tps). |
2019-12-27 |
2023-08-13 |
Not clear |
Emily Hubley, Gaurav Shukla, Yelena Vakhnenko, Robert B Den, Amy S Harriso. Avoidance sectors to reduce dosimetric impact of an irreproducible pannus on setup uncertainty in prostate SBRT VMAT: A case study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:30119882. |
for post-treatment assessment, the case was planned using varian eclipse™ treatment planning system (tps) with two vmat arcs with and without 100° avoidance sectors across the pannus. |
2019-12-27 |
2023-08-13 |
Not clear |
Laure Vieillevigne, Catherine Khamphan, Jordi Saez, Victor Hernande. On the need for tuning the dosimetric leaf gap for stereotactic treatment plans in the Eclipse treatment planning system. Journal of applied clinical medical physics. vol 20. issue 7. 2019-12-20. PMID:31225938. |
the dosimetric leaf gap (dlg) and tongue-and-groove (t&g) effects are critical aspects in the modeling of multileaf collimators (mlc) in the treatment planning system (tps). |
2019-12-20 |
2023-08-13 |
Not clear |
Xinfeng Chen, Eric S Paulson, Ergun Ahunbay, Aydin Sanli, Slade Klawikowski, X Allen L. Measurement validation of treatment planning for a MR-Linac. Journal of applied clinical medical physics. vol 20. issue 7. 2019-12-20. PMID:31254376. |
this effect should be accurately accounted for by the beam models in treatment planning systems (tps). |
2019-12-20 |
2023-08-13 |
Not clear |
Hans L Riis, Martin A Ebert, Pejman Rowshanfarza. Detection of the focal spot motion relative to the collimator axis of a linear accelerator under gantry rotation. Physics in medicine and biology. vol 64. issue 3. 2019-12-18. PMID:30566917. |
in a treatment planning system (tps) the focal spot is assumed to be located on the rotation axis of the collimator at all gantry angles. |
2019-12-18 |
2023-08-13 |
Not clear |
Xiaodong Ma, Zhiyong Yang, Shan Jiang, Guobin Zhang, Shude Cha. A novel auto-positioning method in Iodine-125 seed brachytherapy driven by preoperative planning. Journal of applied clinical medical physics. vol 20. issue 6. 2019-12-18. PMID:31017371. |
in this study, an auto-positioning system was presented, which was composed of a treatment planning system (tps) and a robot-assisted system. |
2019-12-18 |
2023-08-13 |
rat |
Anthony Lausch, Brian Nghiem, Michelle Nielse. iCONE-SRS: Development of inverse treatment planning for cone-based stereotactic radiosurgery. Journal of applied clinical medical physics. vol 20. issue 6. 2019-12-18. PMID:31095851. |
at present, commercially available treatment planning systems (tps) only offer manual planning functionality for cone-based stereotactic radiosurgery (srs) leading to labor intensive treatment planning. |
2019-12-18 |
2023-08-13 |
Not clear |
Anthony Lausch, Brian Nghiem, Michelle Nielse. iCONE-SRS: Development of inverse treatment planning for cone-based stereotactic radiosurgery. Journal of applied clinical medical physics. vol 20. issue 6. 2019-12-18. PMID:31095851. |
our objective was to reduce treatment planning time through development of a simple inverse tps for cone-based srs. |
2019-12-18 |
2023-08-13 |
Not clear |
Matthew M Mille, Jae Won Jung, Choonik Lee, Gleb A Kuzmin, Choonsik Le. Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients. Journal of radiological protection : official journal of the Society for Radiological Protection. vol 38. issue 2. 2019-12-12. PMID:29637904. |
the four dose calculations algorithms considered were as follows: the (1) analytical anisotropic algorithm (aaa) and (2) acuros xb algorithm (acuros xb), as implemented in the eclipse treatment planning system (tps); (3) a monte carlo radiation transport code, egsnrc; and (4) an accelerated monte carlo code, the x-ray voxel monte carlo (xvmc). |
2019-12-12 |
2023-08-13 |
human |
Mohsen Hasani, Bagher Farhood, Mahdi Ghorbani, Hamideh Naderi, Sepideh Saadatmand, Saeed Karimkhani Zandi, Courtney Knau. Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system. Australasian physical & engineering sciences in medicine. vol 42. issue 2. 2019-12-06. PMID:30848440. |
the accuracy of a computed tomography (ct)-relative electron density (red) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (tps). |
2019-12-06 |
2023-08-13 |
Not clear |
Emma Dyce, Dean Cutajar, Peter Metcalfe, Simon Downe. Dose verification for liver target volumes undergoing respiratory motion. Australasian physical & engineering sciences in medicine. vol 42. issue 2. 2019-12-06. PMID:31049839. |
plans were calculated using an elekta monaco treatment planning system (tps) on exhale phase study sets for conformal, volume modulated arc therapy (vmat) and intensity modulated radiation therapy (imrt) techniques, with breathing rates of 8, 14 and 23 bpm. |
2019-12-06 |
2023-08-13 |
Not clear |
Ivan A Brezovich, Xingen Wu, Richard A Popple, Elizabeth Covington, Rex Cardan, Sui Shen, John Fiveash, Markus Bredel, Barton Guthri. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests. Journal of applied clinical medical physics. vol 20. issue 5. 2019-12-03. PMID:30977297. |
to measure dosimetric and spatial accuracy of stereotactic radiosurgery (srs) delivered to targets as small as the trigeminal nerve (tn) using a standard external beam treatment planning system (tps) and multileaf collimator-(mlc) equipped linear accelerator without cones or other special attachments or modifications. |
2019-12-03 |
2023-08-13 |
Not clear |
O Jäkel, B Ackermann, S Ecker, M Ellerbrock, P Heeg, K Henkner, M Winte. Methodology paper: a novel phantom setup for commissioning of scanned ion beam delivery and TPS. Radiation oncology (London, England). vol 14. issue 1. 2019-11-25. PMID:31072382. |
commissioning of treatment planning systems (tps) and beam delivery for scanned light ion beams is an important quality assurance task. |
2019-11-25 |
2023-08-13 |
Not clear |