Daniel Buergy, Abdul Wahab M Sharfo, Ben J M Heijmen, Peter W J Voet, Sebastiaan Breedveld, Frederik Wenz, Frank Lohr, Florian Stiele. Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation. Radiation oncology (London, England). vol 12. issue 1. 2017-08-14. PMID:28143623. fully automated treatment planning of spinal metastases - a comparison to manual planning of volumetric modulated arc therapy for conventionally fractionated irradiation. 2017-08-14 2023-08-13 Not clear
Daniel Buergy, Abdul Wahab M Sharfo, Ben J M Heijmen, Peter W J Voet, Sebastiaan Breedveld, Frederik Wenz, Frank Lohr, Florian Stiele. Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation. Radiation oncology (London, England). vol 12. issue 1. 2017-08-14. PMID:28143623. planning for volumetric modulated arc therapy (vmat) may be time consuming and its use is limited by available staff resources. 2017-08-14 2023-08-13 Not clear
Katherine L Chapman, Matthew E Witek, Hongyu Chen, Timothy N Showalter, Voichita Bar-Ad, Amy S Harriso. Pancreatic cancer planning: Complex conformal vs modulated therapies. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 41. issue 2. 2017-08-01. PMID:26831922. to compare the roles of intensity-modulated radiation therapy (imrt) and volumetric- modulated arc therapy (vmat) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3dcrt) planning for resectable and borderline resectable pancreatic cancer. 2017-08-01 2023-08-13 Not clear
Savino Cilla, Francesco Deodato, Gabriella Macchia, Cinzia Digesù, Anna Ianiro, Pietro Viola, Maurizio Craus, Vincenzo Valentini, Angelo Piermattei, Alessio G Morgant. Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 41. issue 2. 2017-08-01. PMID:26994825. linac-based extracranial radiosurgery with elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: feasibility and initial experience. 2017-08-01 2023-08-13 Not clear
Savino Cilla, Francesco Deodato, Gabriella Macchia, Cinzia Digesù, Anna Ianiro, Pietro Viola, Maurizio Craus, Vincenzo Valentini, Angelo Piermattei, Alessio G Morgant. Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 41. issue 2. 2017-08-01. PMID:26994825. we reported our initial experience in using elekta volumetric modulated arc therapy (vmat) and an anatomy-based treatment planning system (tps) for single high-dose radiosurgery (srs-vmat) of liver metastases. 2017-08-01 2023-08-13 Not clear
Kristofer Kainz, Douglas Prah, Ergun Ahunbay, X Allen L. Clinical experience with planning, quality assurance, and delivery of burst-mode modulated arc therapy. Journal of applied clinical medical physics. vol 17. issue 5. 2017-07-13. PMID:27685123. clinical experience with planning, quality assurance, and delivery of burst-mode modulated arc therapy. 2017-07-13 2023-08-13 Not clear
Sabrina T Heijkoop, Henrike Westerveld, Nina Bijker, Raphael Feije, Abdul W Sharfo, Niek van Wieringen, Jan Willem M Mens, Lukas J A Stalpers, Mischa S Hoogema. Optimal Patient Positioning (Prone Versus Supine) for VMAT in Gynecologic Cancer: A Dosimetric Study on the Effect of Different Margins. International journal of radiation oncology, biology, physics. vol 96. issue 2. 2017-07-03. PMID:27598808. it is unknown whether the historically found dosimetric advantages of treating gynecologic cancer with the patient in a prone position with use of a small-bowel displacement device (belly-board) remain when volumetric arc therapy (vmat) is used and whether these advantages depend on the necessary margin between clinical target volume (ctv) and planning target volume (ptv). 2017-07-03 2023-08-13 Not clear
A R Barbeiro, A Ureba, J A Baeza, R Linares, M Perucha, E Jiménez-Ortega, S Velázquez, J C Mateos, A Lea. 3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry. PloS one. vol 11. issue 11. 2017-06-26. PMID:27870878. a model based on a specific phantom, called quaarc, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (vmat). 2017-06-26 2023-08-13 Not clear
Ying Song, Qiang Wang, Xiaoqin Jiang, Sha Liu, Yingjie Zhang, Sen Ba. Fully automatic volumetric modulated arc therapy plan generation for rectal cancer. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 119. issue 3. 2017-06-21. PMID:27131593. to develop and evaluate a fully automatic rectal planning optimizer (arpo) for volumetric modulated arc therapy (vmat) treatment planning without human interaction. 2017-06-21 2023-08-13 human
Tülay Ercan, Şefik İğdem, Gül Alç. The effect of bladder contrast on dose calculation in volumetric modulated arc therapy planning in patients treated for postoperative prostate cancer. Japanese journal of radiology. vol 34. issue 5. 2017-05-17. PMID:26842552. the effect of bladder contrast on dose calculation in volumetric modulated arc therapy planning in patients treated for postoperative prostate cancer. 2017-05-17 2023-08-13 Not clear
Paul Kinsella, Laura Shields, Patrick McCavana, Brendan McClean, Brian Langa. Determination of MLC model parameters for Monaco using commercial diode arrays. Journal of applied clinical medical physics. vol 17. issue 4. 2017-05-04. PMID:27455495. multileaf collimators (mlcs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat). 2017-05-04 2023-08-13 Not clear
Henry Wang, Lei Xin. Application programming in C# environment with recorded user software interactions and its application in autopilot of VMAT/IMRT treatment planning. Journal of applied clinical medical physics. vol 17. issue 6. 2017-04-27. PMID:27929493. an autopilot scheme of volumetric-modulated arc therapy (vmat)/intensity-modulated radiation therapy (imrt) planning with the guidance of prior knowl-edge is established with recorded interactions between a planner and a commercial treatment planning system (tps). 2017-04-27 2023-08-13 mouse
Michael R Young, David L Craft, Caroline M Colbert, Kyla Remillard, Liam Vanbenthuysen, Yi Wan. Volumetric-modulated arc therapy using multicriteria optimization for body and extremity sarcoma. Journal of applied clinical medical physics. vol 17. issue 6. 2017-04-27. PMID:27929501. this study evaluates the implementation of volumetric-modulated arc therapy (vmat) using multicriteria optimization (mco) in the raystation treatment planning system (tps) for complex sites, namely extremity and body sarcoma. 2017-04-27 2023-08-13 Not clear
B Sarkar, A Manikandan, M Nandy, A Munshi, P Sayan, N Sujath. Influence of monte carlo variance with fluence smoothing in VMAT treatment planning with Monaco TPS. Indian journal of cancer. vol 53. issue 1. 2017-04-21. PMID:27146769. the study aimed to investigate the interplay between monte carlo variance (mcv) and fluence smoothing factor (fsf) in volumetric modulated arc therapy treatment planning by using a sample set of complex treatment planning cases and a x-ray voxel monte carlo-based treatment planning system equipped with tools to tune fluence smoothness as well as mcv. 2017-04-21 2023-08-13 Not clear
B Sarkar, A Pradhan, A Munsh. Do technological advances in linear accelerators improve dosimetric outcomes in stereotaxy? A head-on comparison of seven linear accelerators using volumetric modulated arc therapy-based stereotactic planning. Indian journal of cancer. vol 53. issue 1. 2017-04-21. PMID:27146771. a head-on comparison of seven linear accelerators using volumetric modulated arc therapy-based stereotactic planning. 2017-04-21 2023-08-13 Not clear
D McQuaid, A Dunlop, S Nill, C Franzese, C M Nutting, K J Harrington, K L Newbold, S A Bhid. Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 192. issue 8. 2017-04-03. PMID:27295511. the aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3dcrt), multiple fixed-field intensity-modulated radiotherapy (imrt) and volumetric-modulated arc therapy (vmat) in terms of dose to the planning target volume (ptv), organs at risk (oars) and normal tissue complication probability (ntcp) for delivering ipsilateral radiotherapy. 2017-04-03 2023-08-13 Not clear
Jan Hofmaier, Steffi Kantz, Matthias Söhn, Oliver S Dohm, Stefan Bächle, Markus Alber, Katia Parodi, Claus Belka, Maximilian Niyaz. Hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy. Radiation oncology (London, England). vol 11. issue 1. 2017-04-03. PMID:27609371. hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy. 2017-04-03 2023-08-13 Not clear
Samuel C Peet, Rachael Wilks, Tanya Kairn, Scott B Crow. Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 32. issue 12. 2017-03-31. PMID:27881295. treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3d conformal treatments. 2017-03-31 2023-08-13 Not clear
Jeong-Eun Rah, Gwe-Ya Kim, Do Hoon Oh, Tae Hyun Kim, Jong Won Kim, Dae Yong Kim, Sung Yong Park, Dongho Shi. A treatment planning study of proton arc therapy for para-aortic lymph node tumors: dosimetric evaluation of conventional proton therapy, proton arc therapy, and intensity modulated radiotherapy. Radiation oncology (London, England). vol 11. issue 1. 2017-03-29. PMID:27769262. a treatment planning study of proton arc therapy for para-aortic lymph node tumors: dosimetric evaluation of conventional proton therapy, proton arc therapy, and intensity modulated radiotherapy. 2017-03-29 2023-08-13 Not clear
Chiaki Fujioka, Kentaro Ishii, Toshiko Yamanaga, Ryo Ogino, Shun Kishimoto, Ryu Kawamorita, Takuhito Tada, Toshifumi Nakajim. Optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy. Practical radiation oncology. vol 6. issue 6. 2017-03-28. PMID:27374192. optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy. 2017-03-28 2023-08-13 Not clear