Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Katrina Wright, Janet Ferrari-Anderson, Tamara Barry, Anne Bernard, Elizabeth Brown, Margot Lehman, David Pryo. Improving plan quality for prostate volumetric-modulated arc therapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 4. 2018-08-08. PMID:28784431. |
we critically evaluated the quality and consistency of volumetric-modulated arc therapy (vmat) prostate planning at a single institution to quantify objective measures for plan quality and establish clear guidelines for plan evaluation and quality assurance. |
2018-08-08 |
2023-08-13 |
Not clear |
Elise M Pogson, Sankar Aruguman, Christian R Hansen, Michael Currie, Bradley M Oborn, Samuel J Blake, Josip Juresic, Cesar Ochoa, Jim Yakobi, Alicia Haman, Admir Trtovac, Martin Carolan, Lois Holloway, David I Thwaite. Multi-institutional comparison of simulated treatment delivery errors in ssIMRT, manually planned VMAT and autoplan-VMAT plans for nasopharyngeal radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 42. 2018-07-30. PMID:29173921. |
to quantify the impact of simulated errors for nasopharynx radiotherapy across multiple institutions and planning techniques (auto-plan generated volumetric modulated arc therapy (ap-vmat), manually planned vmat (mp-vmat) and manually planned step and shoot intensity modulated radiation therapy (mp-ssimrt)). |
2018-07-30 |
2023-08-13 |
Not clear |
R Lee MacDonald, Christopher G Thomas, Alasdair Sym. Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning. Medical physics. vol 45. issue 1. 2018-07-27. PMID:29094419. |
dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning. |
2018-07-27 |
2023-08-13 |
Not clear |
Jun-Cong Mo, Jin Huang, Wen-Dong Gu, Min Gao, Zhong-Hua Ning, Jin-Ming Mu, Qi-Lin Li, Hong-Lei Pe. A dosimetric comparison of double-arc volumetric arc therapy, step-shoot intensity modulated radiotherapy and 3D-CRT for left-sided breast cancer radiotherapy after breast-conserving surgery. Technology and health care : official journal of the European Society for Engineering and Medicine. vol 25. issue 5. 2018-07-25. PMID:29103057. |
to compare the dosimetric and efficiency differences for left-sided breast cancer radiotherapy after breast-conserving surgery among three different planning techniques: double-arc volumetric-modulate arc therapy (vmat), step-shoot intensity-modulated radiotherapy (simrt) and three-dimensional conformal radiation therapy (3d-crt). |
2018-07-25 |
2023-08-13 |
Not clear |
Martin Buschmann, Abdul Wahab M Sharfo, Joan Penninkhof, Yvette Seppenwoolde, Gregor Goldner, Dietmar Georg, Sebastiaan Breedveld, Ben J M Heijme. Automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 194. issue 4. 2018-07-24. PMID:29270648. |
automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy. |
2018-07-24 |
2023-08-13 |
Not clear |
Anusheel Munshi, Biplab Sarkar, Satheeshkumar Anbazhagan, Upendra K Giri, Harpreet Kaur, Kanan Jassal, Tharmar Ganesh, Bidhu Kalyan Mohant. Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients. Australasian physical & engineering sciences in medicine. vol 40. issue 3. 2018-07-23. PMID:28523470. |
the study aimed to analyze partial tangential arc vmat treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. |
2018-07-23 |
2023-08-13 |
Not clear |
Anusheel Munshi, Biplab Sarkar, Satheeshkumar Anbazhagan, Upendra K Giri, Harpreet Kaur, Kanan Jassal, Tharmar Ganesh, Bidhu Kalyan Mohant. Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients. Australasian physical & engineering sciences in medicine. vol 40. issue 3. 2018-07-23. PMID:28523470. |
all patients were planned using partial arc vmat in the monaco treatment planning system using two partial arc beams. |
2018-07-23 |
2023-08-13 |
Not clear |
Laurence E Court, Kelly Kisling, Rachel McCarroll, Lifei Zhang, Jinzhong Yang, Hannah Simonds, Monique du Toit, Chris Trauernicht, Hester Burger, Jeannette Parkes, Mike Mejia, Maureen Bojador, Peter Balter, Daniela Branco, Angela Steinmann, Garrett Baltz, Skylar Gay, Brian Anderson, Carlos Cardenas, Anuja Jhingran, Simona Shaitelman, Oliver Bogler, Kathleen Schmeller, David Followill, Rebecca Howell, Christopher Nelson, Christine Peterson, Beth Beadl. Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System. Journal of visualized experiments : JoVE. issue 134. 2018-07-23. PMID:29708544. |
the radiation planning assistant (rpa) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (vmat) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. |
2018-07-23 |
2023-08-13 |
Not clear |
Megumi Uto, Takashi Mizowaki, Kengo Ogura, Yuki Miyabe, Mitsuhiro Nakamura, Nobutaka Mukumoto, Hideaki Hirashima, Masahiro Hiraok. Volumetric modulated Dynamic WaveArc therapy reduces the dose to the hippocampus in patients with pituitary adenomas and craniopharyngiomas. Practical radiation oncology. vol 7. issue 6. 2018-07-09. PMID:28666908. |
because vmdwat appears to reduce the hippocampal dose in patients with pituitary adenomas and craniopharyngiomas, we performed a planning study to compare the dose distribution of volumetric-modulated arc therapy using only a coplanar arc (covmat) and vmdwat. |
2018-07-09 |
2023-08-13 |
Not clear |
Ghulam Murtaza, Stefania Cora, Ehsan Ullah Kha. Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution. Journal of radiation research. vol 58. issue 4. 2018-05-14. PMID:27974507. |
most previous vmat planning and dosimetric work for gs resolution has been conducted for single arc vmat. |
2018-05-14 |
2023-08-13 |
Not clear |
Jina Kim, Hong Seok Jang, Yeon Sil Kim, Byung Ock Choi, Young-Nam Kan. Comparison of spinal Stereotactic Body Radiotherapy (SBRT) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28526192. |
comparison of spinal stereotactic body radiotherapy (sbrt) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy. |
2018-05-09 |
2023-08-13 |
Not clear |
Kanabu Nawa, Akihiro Haga, Akihiro Nomoto, Raniel A Sarmiento, Kenshiro Shiraishi, Hideomi Yamashita, Keiichi Nakagaw. Evaluation of a commercial automatic treatment planning system for prostate cancers. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28549556. |
recent developments in radiation oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) planning. |
2018-05-09 |
2023-08-13 |
Not clear |
Ganesh Narayanasamy, Sotirios Stathakis, Alonso N Gutierrez, Evangelos Pappas, Richard Crownover, John R Floyd, Niko Papanikolao. A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases. Technology in cancer research & treatment. vol 16. issue 5. 2018-05-03. PMID:27612917. |
in this treatment planning study, we compare the plan quality and delivery parameters for the treatment of multiple brain metastases using 2 monoisocentric techniques: the multiple metastases element from brainlab and the rapidarc volumetric-modulated arc therapy from varian medical systems. |
2018-05-03 |
2023-08-13 |
Not clear |
Lijun Ma, Lei Wang, Chia-Lin Tseng, Arjun Sahga. Emerging technologies in stereotactic body radiotherapy. Chinese clinical oncology. vol 6. issue Suppl 2. 2018-04-20. PMID:28917250. |
as a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (vmat), sbrt has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. |
2018-04-20 |
2023-08-13 |
Not clear |
Wei Liu, Samir H Patel, Daniel P Harrington, Yanle Hu, Xiaoning Ding, Jiajian Shen, Michele Y Halyard, Steven E Schild, William W Wong, Gary E Ezzell, Martin Bue. Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer. Journal of applied clinical medical physics. vol 18. issue 4. 2018-04-02. PMID:28503916. |
this work is to show which is more relevant to cause local failures (lfs) due to patient setup uncertainty between the planning target volume (ptv) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (h&n) cancer treated with volumetric-modulated arc therapy (vmat). |
2018-04-02 |
2023-08-13 |
human |
Hideharu Miura, Shuichi Ozawa, Yasushi Nagat. Efficacy of robust optimization plan with partial-arc VMAT for photon volumetric-modulated arc therapy: A phantom study. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28691343. |
this study investigated position dependence in planning target volume (ptv)-based and robust optimization plans using full-arc and partial-arc volumetric modulated arc therapy (vmat). |
2018-04-02 |
2023-08-13 |
Not clear |
Marius Treutwein, Matthias Hipp, Oliver Koelbl, Barbara Doble. Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28857432. |
volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators. |
2018-04-02 |
2023-08-13 |
Not clear |
Primož Peterlin, Karmen Stanič, Ignasi Méndez, Andrej Strojni. Treating lung cancer with dynamic conformal arc therapy: a dosimetric study. Radiation oncology (London, England). vol 12. issue 1. 2018-03-26. PMID:28578699. |
dynamic conformal arc therapy (dcat) offers a shorter treatment time than conventional 3d conformal radiotherapy (3d crt) and is usually available even in departments without inverse planning possibilities. |
2018-03-26 |
2023-08-13 |
Not clear |
Te-Yu Chyou, Friedlieb Loren. Couch modelling for volumetric modulated arc therapy (VMAT). Australasian physical & engineering sciences in medicine. vol 40. issue 2. 2018-03-26. PMID:28597229. |
for this purpose two models of the varian exact couch (varian medical systems, palo alto, ca, usa) for use in the planning of volumetric modulated arc therapy (vmat) were created in monaco 5.1 (elekta, stockholm, sweden). |
2018-03-26 |
2023-08-13 |
Not clear |
Sankar Arumugam, Megan Berry, Cesar Ochoa, Aitang Xing, Bradley Beeksma, Philip Via. Dose discrepancy between planning system estimation and measurement in spine stereotactic body radiation therapy: A case report. Journal of medical imaging and radiation oncology. vol 61. issue 5. 2018-03-13. PMID:28477339. |
a dual arc volumetric modulated arc therapy plan was generated on the pinnacle treatment planning system (tps) with a 6 mv elekta machine using gantry control point spacing of 4°. |
2018-03-13 |
2023-08-13 |
Not clear |