All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
Yuliang Huang, Haizhen Yue, Meijiao Wang, Sha Li, Jian Zhang, Zhuolun Liu, Yibao Zhan. Fully automated searching for the optimal VMAT jaw settings based on Eclipse Scripting Application Programming Interface (ESAPI) and RapidPlan knowledge-based planning. Journal of applied clinical medical physics. vol 19. issue 3. 2018-10-04. PMID:29577614. eclipse treatment planning system has not been able to optimize the jaw positions for volumetric modulated arc therapy (vmat). 2018-10-04 2023-08-13 Not clear
Juanqi Wang, Zhi Chen, Weiwei Li, Wei Qian, Xiaosheng Wang, Weigang H. A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for nasopharyngeal carcinoma. Radiation oncology (London, England). vol 13. issue 1. 2018-10-03. PMID:29769101. a new strategy for volumetric-modulated arc therapy planning using autoplanning based multicriteria optimization for nasopharyngeal carcinoma. 2018-10-03 2023-08-13 Not clear
Keisuke Usui, Keisuke Sasai, Koichi Ogaw. Effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning. Radiological physics and technology. vol 11. issue 2. 2018-09-26. PMID:29542016. effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning. 2018-09-26 2023-08-13 Not clear
Jens Fleckenstein, Judit Boda-Heggemann, Kerstin Siebenlist, Tanya Gudzheva, Natallia Prakofyeva, Frank Lohr, Frederik Wenz, Anna Simeonova-Chergo. Non-coplanar VMAT combined with non-uniform dose prescription markedly reduces lung dose in breath-hold lung SBRT. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 194. issue 9. 2018-09-20. PMID:29802434. in this retrospective treatment planning study, the effect of a uniform and non-uniform planning target volume (ptv) dose coverage as well as a coplanar and non-coplanar volumetric modulated arc therapy (vmat) delivery approach for lung stereotactic body radiation therapy (sbrt) in deep inspiration breath-hold (dibh) were compared. 2018-09-20 2023-08-13 Not clear
Abdul Wahab M Sharfo, Florian Stieler, Oskar Kupfer, Ben J M Heijmen, Maarten L P Dirkx, Sebastiaan Breedveld, Frederik Wenz, Frank Lohr, Judit Boda-Heggemann, Daniel Buerg. Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer. Radiation oncology (London, England). vol 13. issue 1. 2018-09-19. PMID:29685166. postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (ptv) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (vmat) planning. 2018-09-19 2023-08-13 Not clear
Matthew Mallory, Damodar Pokhrel, Rajeev Badkul, Hongyu Jiang, Christopher Lominska, Fen Wan. Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy. Journal of applied clinical medical physics. vol 19. issue 2. 2018-09-14. PMID:29349867. volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy. 2018-09-14 2023-08-13 Not clear
Stephen Zieminski, Melin Khandekar, Yi Wan. Assessment of multi-criteria optimization (MCO) for volumetric modulated arc therapy (VMAT) in hippocampal avoidance whole brain radiation therapy (HA-WBRT). Journal of applied clinical medical physics. vol 19. issue 2. 2018-09-14. PMID:29411526. this study compared the dosimetric performance of (a) volumetric modulated arc therapy (vmat) with standard optimization (std) and (b) multi-criteria optimization (mco) to (c) intensity modulated radiation therapy (imrt) with mco for hippocampal avoidance whole brain radiation therapy (ha-wbrt) in raystation treatment planning system (tps). 2018-09-14 2023-08-13 Not clear
Motoharu Sasaki, Masahide Tominaga, Takeshi Kamomae, Hitoshi Ikushima, Motonori Kitaoka, Ryota Bando, Kanako Sakuragawa, Masataka Oit. Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning. Japanese journal of radiology. vol 35. issue 9. 2018-09-05. PMID:28647834. influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning. 2018-09-05 2023-08-13 Not clear
Motoharu Sasaki, Masahide Tominaga, Takeshi Kamomae, Hitoshi Ikushima, Motonori Kitaoka, Ryota Bando, Kanako Sakuragawa, Masataka Oit. Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning. Japanese journal of radiology. vol 35. issue 9. 2018-09-05. PMID:28647834. the aim of this study was to quantify the effect of multi-leaf collimators (mlcs) with different leaf widths on the planning of intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat). 2018-09-05 2023-08-13 Not clear
Yoshihiro Ueda, Jun-Ichi Fukunaga, Tatsuya Kamima, Yumiko Adachi, Kiyoshi Nakamatsu, Hajime Monze. Evaluation of multiple institutions' models for knowledge-based planning of volumetric modulated arc therapy (VMAT) for prostate cancer. Radiation oncology (London, England). vol 13. issue 1. 2018-08-31. PMID:29558940. evaluation of multiple institutions' models for knowledge-based planning of volumetric modulated arc therapy (vmat) for prostate cancer. 2018-08-31 2023-08-13 Not clear
Yoshihiro Ueda, Jun-Ichi Fukunaga, Tatsuya Kamima, Yumiko Adachi, Kiyoshi Nakamatsu, Hajime Monze. Evaluation of multiple institutions' models for knowledge-based planning of volumetric modulated arc therapy (VMAT) for prostate cancer. Radiation oncology (London, England). vol 13. issue 1. 2018-08-31. PMID:29558940. the aim of this study was to evaluate the performance of a commercial knowledge-based planning system, in volumetric modulated arc therapy for prostate cancer at multiple radiation therapy departments. 2018-08-31 2023-08-13 Not clear
Alyssa Olson, Kristine Phillips, Tamara Eng, Nishele Lenards, Ashley Hunzeker, Daniel Lewis, Douglas Bauman. Assessing dose variance from immobilization devices in VMAT head and neck treatment planning: A retrospective case study analysis. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 43. issue 1. 2018-08-30. PMID:28927550. a retrospective case study was performed to evaluate beam attenuation from head and neck (hn) immobilization devices in volumetric-modulated arc therapy using the eclipse treatment planning system and the anisotropic analytical algorithm. 2018-08-30 2023-08-13 Not clear
Cem Onal, Yemliha Dölek, Berna Akkuş Yıldırı. Dosimetric comparison of 3-dimensional conformal radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for postoperative gastric cancer patients. Japanese journal of radiology. vol 36. issue 1. 2018-08-22. PMID:29101643. to compare dosimetric data for the planning target volume (ptv) and organs at risk (oars) between 3-dimensional conformal radiotherapy (3dcrt), volumetric modulated arc therapy (vmat), and helical tomotherapy [1]. 2018-08-22 2023-08-13 Not clear
Yudai Kai, Ryo Toya, Tetsuo Saito, Akiko Kuraoka, Yoshinobu Shimohigashi, Yuji Nakaguchi, Masato Maruyama, Ryuji Murakami, Yasuyuki Yamashita, Natsuo Oy. Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study. Journal of medical radiation sciences. vol 65. issue 1. 2018-08-20. PMID:28755441. plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: a planning study. 2018-08-20 2023-08-13 Not clear
Tatsuya Kamima, Hiromi Baba, Ryo Takahashi, Mikiko Yamashita, Yasuharu Sugawara, Daisuke Kawai, Toshijiro Yamamoto, Aya Satou, Hidenobu Tachiban. Multi-institutional comparison of computer-based independent dose calculation for intensity modulated radiation therapy and volumetric modulated arc therapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 45. 2018-08-20. PMID:29472094. no multi-institutional studies of computer-based independent dose calculation have addressed the discrepancies among radiotherapy treatment planning systems (tpss) and the verification programs for intensity modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat). 2018-08-20 2023-08-13 Not clear
Katrina Wright, Janet Ferrari-Anderson, Tamara Barry, Anne Bernard, Elizabeth Brown, Margot Lehman, David Pryo. Improving plan quality for prostate volumetric-modulated arc therapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 4. 2018-08-08. PMID:28784431. we critically evaluated the quality and consistency of volumetric-modulated arc therapy (vmat) prostate planning at a single institution to quantify objective measures for plan quality and establish clear guidelines for plan evaluation and quality assurance. 2018-08-08 2023-08-13 Not clear
Elise M Pogson, Sankar Aruguman, Christian R Hansen, Michael Currie, Bradley M Oborn, Samuel J Blake, Josip Juresic, Cesar Ochoa, Jim Yakobi, Alicia Haman, Admir Trtovac, Martin Carolan, Lois Holloway, David I Thwaite. Multi-institutional comparison of simulated treatment delivery errors in ssIMRT, manually planned VMAT and autoplan-VMAT plans for nasopharyngeal radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 42. 2018-07-30. PMID:29173921. to quantify the impact of simulated errors for nasopharynx radiotherapy across multiple institutions and planning techniques (auto-plan generated volumetric modulated arc therapy (ap-vmat), manually planned vmat (mp-vmat) and manually planned step and shoot intensity modulated radiation therapy (mp-ssimrt)). 2018-07-30 2023-08-13 Not clear
R Lee MacDonald, Christopher G Thomas, Alasdair Sym. Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning. Medical physics. vol 45. issue 1. 2018-07-27. PMID:29094419. dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning. 2018-07-27 2023-08-13 Not clear
Jun-Cong Mo, Jin Huang, Wen-Dong Gu, Min Gao, Zhong-Hua Ning, Jin-Ming Mu, Qi-Lin Li, Hong-Lei Pe. A dosimetric comparison of double-arc volumetric arc therapy, step-shoot intensity modulated radiotherapy and 3D-CRT for left-sided breast cancer radiotherapy after breast-conserving surgery. Technology and health care : official journal of the European Society for Engineering and Medicine. vol 25. issue 5. 2018-07-25. PMID:29103057. to compare the dosimetric and efficiency differences for left-sided breast cancer radiotherapy after breast-conserving surgery among three different planning techniques: double-arc volumetric-modulate arc therapy (vmat), step-shoot intensity-modulated radiotherapy (simrt) and three-dimensional conformal radiation therapy (3d-crt). 2018-07-25 2023-08-13 Not clear
Martin Buschmann, Abdul Wahab M Sharfo, Joan Penninkhof, Yvette Seppenwoolde, Gregor Goldner, Dietmar Georg, Sebastiaan Breedveld, Ben J M Heijme. Automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 194. issue 4. 2018-07-24. PMID:29270648. automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy. 2018-07-24 2023-08-13 Not clear