Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Ghulam Murtaza, Stefania Cora, Ehsan Ullah Kha. Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution. Journal of radiation research. vol 58. issue 4. 2018-05-14. PMID:27974507. |
most previous vmat planning and dosimetric work for gs resolution has been conducted for single arc vmat. |
2018-05-14 |
2023-08-13 |
Not clear |
Jina Kim, Hong Seok Jang, Yeon Sil Kim, Byung Ock Choi, Young-Nam Kan. Comparison of spinal Stereotactic Body Radiotherapy (SBRT) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28526192. |
comparison of spinal stereotactic body radiotherapy (sbrt) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy. |
2018-05-09 |
2023-08-13 |
Not clear |
Kanabu Nawa, Akihiro Haga, Akihiro Nomoto, Raniel A Sarmiento, Kenshiro Shiraishi, Hideomi Yamashita, Keiichi Nakagaw. Evaluation of a commercial automatic treatment planning system for prostate cancers. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28549556. |
recent developments in radiation oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) planning. |
2018-05-09 |
2023-08-13 |
Not clear |
Ganesh Narayanasamy, Sotirios Stathakis, Alonso N Gutierrez, Evangelos Pappas, Richard Crownover, John R Floyd, Niko Papanikolao. A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases. Technology in cancer research & treatment. vol 16. issue 5. 2018-05-03. PMID:27612917. |
in this treatment planning study, we compare the plan quality and delivery parameters for the treatment of multiple brain metastases using 2 monoisocentric techniques: the multiple metastases element from brainlab and the rapidarc volumetric-modulated arc therapy from varian medical systems. |
2018-05-03 |
2023-08-13 |
Not clear |
Lijun Ma, Lei Wang, Chia-Lin Tseng, Arjun Sahga. Emerging technologies in stereotactic body radiotherapy. Chinese clinical oncology. vol 6. issue Suppl 2. 2018-04-20. PMID:28917250. |
as a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (vmat), sbrt has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. |
2018-04-20 |
2023-08-13 |
Not clear |
Wei Liu, Samir H Patel, Daniel P Harrington, Yanle Hu, Xiaoning Ding, Jiajian Shen, Michele Y Halyard, Steven E Schild, William W Wong, Gary E Ezzell, Martin Bue. Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer. Journal of applied clinical medical physics. vol 18. issue 4. 2018-04-02. PMID:28503916. |
this work is to show which is more relevant to cause local failures (lfs) due to patient setup uncertainty between the planning target volume (ptv) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (h&n) cancer treated with volumetric-modulated arc therapy (vmat). |
2018-04-02 |
2023-08-13 |
human |
Hideharu Miura, Shuichi Ozawa, Yasushi Nagat. Efficacy of robust optimization plan with partial-arc VMAT for photon volumetric-modulated arc therapy: A phantom study. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28691343. |
this study investigated position dependence in planning target volume (ptv)-based and robust optimization plans using full-arc and partial-arc volumetric modulated arc therapy (vmat). |
2018-04-02 |
2023-08-13 |
Not clear |
Marius Treutwein, Matthias Hipp, Oliver Koelbl, Barbara Doble. Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28857432. |
volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators. |
2018-04-02 |
2023-08-13 |
Not clear |
Primož Peterlin, Karmen Stanič, Ignasi Méndez, Andrej Strojni. Treating lung cancer with dynamic conformal arc therapy: a dosimetric study. Radiation oncology (London, England). vol 12. issue 1. 2018-03-26. PMID:28578699. |
dynamic conformal arc therapy (dcat) offers a shorter treatment time than conventional 3d conformal radiotherapy (3d crt) and is usually available even in departments without inverse planning possibilities. |
2018-03-26 |
2023-08-13 |
Not clear |
Te-Yu Chyou, Friedlieb Loren. Couch modelling for volumetric modulated arc therapy (VMAT). Australasian physical & engineering sciences in medicine. vol 40. issue 2. 2018-03-26. PMID:28597229. |
for this purpose two models of the varian exact couch (varian medical systems, palo alto, ca, usa) for use in the planning of volumetric modulated arc therapy (vmat) were created in monaco 5.1 (elekta, stockholm, sweden). |
2018-03-26 |
2023-08-13 |
Not clear |
Sankar Arumugam, Megan Berry, Cesar Ochoa, Aitang Xing, Bradley Beeksma, Philip Via. Dose discrepancy between planning system estimation and measurement in spine stereotactic body radiation therapy: A case report. Journal of medical imaging and radiation oncology. vol 61. issue 5. 2018-03-13. PMID:28477339. |
a dual arc volumetric modulated arc therapy plan was generated on the pinnacle treatment planning system (tps) with a 6 mv elekta machine using gantry control point spacing of 4°. |
2018-03-13 |
2023-08-13 |
Not clear |
Eva Sau Fan Liu, Vincent Wing Cheung Wu, Benjamin Harris, Matthew Foote, Margot Lehman, Lawrence Wing Chi Cha. Vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 2. 2018-03-12. PMID:28318935. |
vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis. |
2018-03-12 |
2023-08-13 |
Not clear |
Eva Sau Fan Liu, Vincent Wing Cheung Wu, Benjamin Harris, Matthew Foote, Margot Lehman, Lawrence Wing Chi Cha. Vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 2. 2018-03-12. PMID:28318935. |
long planning time in volumetric-modulated arc stereotactic radiotherapy (vma-srt) cases can limit its clinical efficiency and use. |
2018-03-12 |
2023-08-13 |
Not clear |
Juanqi Wang, Zhaozhi Yang, Weigang Hu, Zhi Chen, Xiaoli Yu, Xiaomao Gu. Intensity modulated radiotherapy with fixed collimator jaws for locoregional left-sided breast cancer irradiation. Oncotarget. vol 8. issue 20. 2018-03-05. PMID:28402279. |
for each patient, treatment plans using different planning techniques, i.e., volumetric modulated arc therapy (vmat), tangential imrt (tangential-imrt), and imrt with fjt (fjt-imrt) were developed for dosimetric comparisons. |
2018-03-05 |
2023-08-13 |
Not clear |
Assi Valve, Jani Keyriläinen, Jarmo Kulmal. Compass model-based quality assurance for stereotactic VMAT treatment plans. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 44. 2018-01-30. PMID:29254590. |
to use compass as a model-based quality assurance (qa) tool for stereotactic body radiation therapy (sbrt) and stereotactic radiation therapy (srt) volumetric modulated arc therapy (vmat) treatment plans calculated with eclipse treatment planning system (tps). |
2018-01-30 |
2023-08-13 |
Not clear |
Mehdi Mahnam, Michel Gendreau, Nadia Lahrichi, Louis-Martin Roussea. Simultaneous delivery time and aperture shape optimization for the volumetric-modulated arc therapy (VMAT) treatment planning problem. Physics in medicine and biology. vol 62. issue 14. 2017-12-11. PMID:28524822. |
simultaneous delivery time and aperture shape optimization for the volumetric-modulated arc therapy (vmat) treatment planning problem. |
2017-12-11 |
2023-08-13 |
Not clear |
Mehdi Mahnam, Michel Gendreau, Nadia Lahrichi, Louis-Martin Roussea. Simultaneous delivery time and aperture shape optimization for the volumetric-modulated arc therapy (VMAT) treatment planning problem. Physics in medicine and biology. vol 62. issue 14. 2017-12-11. PMID:28524822. |
in this paper, we propose a novel heuristic algorithm for the volumetric-modulated arc therapy treatment planning problem, optimizing the trade-off between delivery time and treatment quality. |
2017-12-11 |
2023-08-13 |
Not clear |
Kengo Ogura, Yasuhiro Kosaka, Toshiyuki Imagumbai, Kazuhito Ueki, Ryo Narukami, Takayuki Hattori, Masaki Kokub. Modifying the planning target volume to optimize the dose distribution in dynamic conformal arc therapy for large metastatic brain tumors. Japanese journal of radiology. vol 35. issue 6. 2017-11-13. PMID:28386823. |
modifying the planning target volume to optimize the dose distribution in dynamic conformal arc therapy for large metastatic brain tumors. |
2017-11-13 |
2023-08-13 |
Not clear |
Ying Niu, Gregory T Betzel, Xiaocheng Yang, Minzhi Gui, William C Parke, Byongyong Yi, Cedric X Y. Planning 4D intensity-modulated arc therapy for tumor tracking with a multileaf collimator. Physics in medicine and biology. vol 62. issue 4. 2017-10-24. PMID:28052050. |
planning 4d intensity-modulated arc therapy for tumor tracking with a multileaf collimator. |
2017-10-24 |
2023-08-13 |
Not clear |
Jian-Jian Qiu, Weiqiang Ge, Libo Zhang, Ye Yao, Xiangpeng Zhen. The Feasibility and Efficiency of Volumetric Modulated Arc Therapy-Based Breath Control Stereotactic Body Radiotherapy for Liver Tumors. Technology in cancer research & treatment. vol 15. issue 5. 2017-10-19. PMID:26206766. |
in conclusion, it is feasible to utilize volumetric modulated arc therapy in the treatment planning of stereotactic body radiotherapy for liver tumors under breath control mode. |
2017-10-19 |
2023-08-13 |
Not clear |