All Relations between planning and retina cone cell

Publication Sentence Publish Date Extraction Date Species
C Phongnarisorn, J Srisomboon, S Khunamornpong, S Siriaungkul, P Suprasert, K Charoenkwan, C Cheewakriangkrai, S Siriaree, T Pantasr. The risk of residual neoplasia in women with microinvasive squamous cervical carcinoma and positive cone margins. International journal of gynecological cancer : official journal of the International Gynecological Cancer Society. vol 16. issue 2. 2006-10-12. PMID:16681742. repeat cone biopsy should be performed to determine exactly the severity of lesion before planning treatment. 2006-10-12 2023-08-12 Not clear
Dov M Almog, James LaMar, Frank R LaMar, Frank LaMa. Cone beam computerized tomography-based dental imaging for implant planning and surgical guidance, Part 1: Single implant in the mandibular molar region. The Journal of oral implantology. vol 32. issue 2. 2006-06-07. PMID:16704109. cone beam computerized tomography-based dental imaging for implant planning and surgical guidance, part 1: single implant in the mandibular molar region. 2006-06-07 2023-08-12 Not clear
Maria Eugenia Guerrero, Reinhilde Jacobs, Miet Loubele, Filip Schutyser, Paul Suetens, Daniel van Steenbergh. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clinical oral investigations. vol 10. issue 1. 2006-05-25. PMID:16482455. state-of-the-art on cone beam ct imaging for preoperative planning of implant placement. 2006-05-25 2023-08-12 Not clear
Maria Eugenia Guerrero, Reinhilde Jacobs, Miet Loubele, Filip Schutyser, Paul Suetens, Daniel van Steenbergh. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clinical oral investigations. vol 10. issue 1. 2006-05-25. PMID:16482455. as the use of endosseous implants has revolutionized oral rehabilitation, a specialized technique has become available for the preoperative planning of oral implant placement: cone beam computed tomography (ct). 2006-05-25 2023-08-12 Not clear
Maria Eugenia Guerrero, Reinhilde Jacobs, Miet Loubele, Filip Schutyser, Paul Suetens, Daniel van Steenbergh. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clinical oral investigations. vol 10. issue 1. 2006-05-25. PMID:16482455. the present review deals with imaging modalities available for preoperative planning purposes with a specific focus on the use of the cone beam ct and software for planning of oral implant surgery. 2006-05-25 2023-08-12 Not clear
Scott D Gan. Conventional CT and cone beam CT for improved dental diagnostics and implant planning. Dental implantology update. vol 16. issue 12. 2006-02-28. PMID:16422471. conventional ct and cone beam ct for improved dental diagnostics and implant planning. 2006-02-28 2023-08-12 Not clear
Anders Traberg Hansen, Jørgen B Petersen, Morten Høyer, Jens Juul Christense. Comparison of two dose calculation methods applied to extracranial stereotactic radiotherapy treatment planning. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 77. issue 1. 2006-01-10. PMID:16246744. in addition, the dose calculation with the collapsed cone convolution algorithm is also performed with modified field sizes in order to match the planning target volume (ptv) peripheral dose of the pencil beam based treatment. 2006-01-10 2023-08-12 Not clear
William S Moor. Cone beam CT: a new tool for esthetic implant planning. Texas dental journal. vol 122. issue 4. 2005-10-18. PMID:15984367. cone beam ct: a new tool for esthetic implant planning. 2005-10-18 2023-08-12 Not clear
Anders Ahnesjö, Lars Weber, Anders Murman, Mikael Saxner, Ingvar Thorslund, Erik Traneu. Beam modeling and verification of a photon beam multisource model. Medical physics. vol 32. issue 6. 2005-09-20. PMID:16013730. the evaluation is based on user data for a pencil kernel algorithm and a point kernel algorithm (collapsed cone) used in the clinical treatment planning systems helax-tms and nucletron-oncentra. 2005-09-20 2023-08-12 Not clear
N Reynaert, M Coghe, B De Smedt, L Paelinck, B Vanderstraeten, W De Gersem, B Van Duyse, C De Wagter, W De Neve, H Thieren. The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations. Physics in medicine and biology. vol 50. issue 5. 2005-07-11. PMID:15798258. two monte carlo dose engines for radiotherapy treatment planning, namely a beta release of peregrine and mcde (monte carlo dose engine), were compared with helax-tms (collapsed cone superposition convolution) for a head and neck patient for the elekta sli plus linear accelerator. 2005-07-11 2023-08-12 Not clear
R Marmulla, R Wörtche, J Mühling, S Hassfel. Geometric accuracy of the NewTom 9000 Cone Beam CT. Dento maxillo facial radiology. vol 34. issue 1. 2005-04-04. PMID:15709102. geometric accuracy of the newtom 9000 cone beam ct. to determine the geometric accuracy of digital volume tomograms to assess their usability for implant planning. 2005-04-04 2023-08-12 Not clear
Andrew Nisbet, Ian Beange, Hans-Stephan Vollmar, Catherine Irvine, Andrew Morgan, David I Thwaite. Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 73. issue 1. 2005-02-25. PMID:15465150. this work reports a detailed study carried out in two uk radiotherapy centres of the dosimetric accuracy of the collapsed cone algorithm of a commercial treatment planning system (helax-tms) in simulated clinical situations. 2005-02-25 2023-08-12 Not clear
W Xiong, J Li, L Chen, R A Price, G Freedman, M Ding, L Qin, J Yang, C M M. Optimization of combined electron and photon beams for breast cancer. Physics in medicine and biology. vol 49. issue 10. 2004-12-21. PMID:15214536. five different planning techniques have been developed for this study based on a standard photon beam whole breast treatment and an electron beam tumour bed cone down. 2004-12-21 2023-08-12 Not clear
P K N Yu, T Cheung, M J Butso. Prostate dosimetry in an anthropomorphic phantom. Australasian physical & engineering sciences in medicine. vol 27. issue 2. 2004-11-02. PMID:15462587. dose in the prostate and rectum region were calculated for 6mv and 18mv photon beams on an anthropomorphic phantom with a collapsed cone convolution method using a 3-d planning system. 2004-11-02 2023-08-12 Not clear
C Irvine, A Morgan, A Crellin, A Nisbet, I Beang. The clinical implications of the collapsed cone planning algorithm. Clinical oncology (Royal College of Radiologists (Great Britain)). vol 16. issue 2. 2004-06-15. PMID:15074739. the clinical implications of the collapsed cone planning algorithm. 2004-06-15 2023-08-12 Not clear
Weihua Fu, Jianrong Dai, Yimin H. The influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer irradiation. Bio-medical materials and engineering. vol 14. issue 1. 2004-06-10. PMID:14757959. to analyze the influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer, three dimension conformal treatment (3d-crt) plans of using 6 mv and 18 mv x-ray respectively for a lung cancer case have been worked out by using pencil beam algorithm and collapsed cone algorithm provided by helax-tms treatment planning system for the same radiation field arrangement for both energies. 2004-06-10 2023-08-12 Not clear
P Tangboonduangjit, I Wu, M Butson, A Rosenfeld, P Metcalf. Intensity modulated radiation therapy: film verification of planar dose maps. Australasian physical & engineering sciences in medicine. vol 26. issue 4. 2004-04-28. PMID:14995065. dose profiles derived from the two films are compared with doses obtained using a radiotherapy dose planning system (philips-pinnacle) which calculates planar dose using a collapsed cone convolution algorithm. 2004-04-28 2023-08-12 Not clear
P Sukovi. Cone beam computed tomography in craniofacial imaging. Orthodontics & craniofacial research. vol 6 Suppl 1. 2004-01-06. PMID:14606532. when combined with application-specific software tools, cone beam computed tomography can provide dentomaxillofacial practitioners with a complete solution for performing specific diagnostic and surgical tasks, such as dental implant planning. 2004-01-06 2023-08-12 Not clear
Fernando Mot. Microinvasive squamous carcinoma of the cervix: treatment modalities. Acta obstetricia et gynecologica Scandinavica. vol 82. issue 6. 2003-07-22. PMID:12780420. individualization of therapy based on an exhaustive pathological evaluation of an adequate cone biopsy specimen is of paramount importance for treatment planning and disease control. 2003-07-22 2023-08-12 Not clear
J L Bedford, P J Childs, V Nordmark Hansen, M A Mosleh-Shirazi, F Verhaegen, A P Warringto. Commissioning and quality assurance of the Pinnacle(3) radiotherapy treatment planning system for external beam photons. The British journal of radiology. vol 76. issue 903. 2003-05-22. PMID:12684232. isocentric doses were compared between pinnacle(3)'s collapsed cone convolution algorithm and the bentley-milan algorithm within the target-2 treatment planning system. 2003-05-22 2023-08-12 Not clear