All Relations between planning and retina cone cell

Publication Sentence Publish Date Extraction Date Species
Puspen Chakraborty, Hidetoshi Saitoh, Yuta Miyake, Tenyoh Suzuki, Weishan Chan. Estimation of the lateral variation of photon beam energy spectra using the percentage depth dose reconstruction method. Radiological physics and technology. 2024-09-06. PMID:39240450. in photon-collapsed cone convolution (pccc) algorithm of the monaco treatment planning system (tps), the central-axis energy spectrum is assumed constant throughout the entire irradiation area. 2024-09-06 2024-09-08 Not clear
Xu Chen, Yunkui Pang, Pew-Thian Yap, Jun Lia. Multi-scale anatomical regularization for domain-adaptive segmentation of pelvic CBCT images. Medical physics. 2024-09-03. PMID:39225652. cone beam computed tomography (cbct) image segmentation is crucial in prostate cancer radiotherapy, enabling precise delineation of the prostate gland for accurate treatment planning and delivery. 2024-09-03 2024-09-05 Not clear
S A Yoganathan, Mohamed Riyas, Renilmon Sukumaran, Rabih Hammoud, Noora Al-Hammad. Ultra-Hypofractionated Prostate Radiotherapy With Online Adaptive Technique: A Case Report. Cureus. vol 16. issue 7. 2024-08-08. PMID:39114185. this study reports the planning process of uhf rt utilizing the cone beam computed tomography (cbct)-based online adaptive radiotherapy (oart) treatment with the ethos system, focusing on a comparative analysis between oart and image-guided radiotherapy (igrt) plans. 2024-08-08 2024-08-10 Not clear
Xiaoqian Chen, Richard L J Qiu, Junbo Peng, Joseph W Shelton, Chih-Wei Chang, Xiaofeng Yang, Aparna H Kesarwal. CBCT-based synthetic CT image generation using a diffusion model for CBCT-guided lung radiotherapy. Medical physics. 2024-08-01. PMID:39088750. although cone beam computed tomography (cbct) has lower resolution compared to planning cts (pct), its lower dose, higher high-contrast resolution, and shorter scanning time support its widespread use in clinical applications, especially in ensuring accurate patient positioning during the image-guided radiation therapy (igrt) process. 2024-08-01 2024-08-05 Not clear
b' Do\\xc4\\x9fan Ilgaz Kaya, Samed \\xc5\\x9eat\\xc4\\xb1r, Beyza \\xc3\\x96zta\\xc5\\x9f, Hasan Y\\xc4\\xb1ld\\xc4\\xb1r\\xc4\\xb1m, Ahmet Akt\\xc4\\xb. Risk Assessment of Nasal Cavity Perforation in the Maxilla: A Virtual Implant Placement Study Using Cone Beam Computed Tomography. Diagnostics (Basel, Switzerland). vol 14. issue 14. 2024-07-27. PMID:39061617.' cone beam computed tomography (cbct) provides a three-dimensional assessment, enhancing surgical planning accuracy and potentially reducing complications. 2024-07-27 2024-07-29 Not clear
Ignacio Pedrinaci, German O Gallucci, Alejandro Lanis, Bernard Friedland, Kevser Pala, Adam Hamilto. Computer-Assisted Implant Planning: A Review of Data Registration Techniques. The International journal of periodontics & restorative dentistry. vol 0. issue 0. 2024-07-26. PMID:39058947. computer-assisted implant planning allows for a comprehensive treatment plan by combining radiographic data provided by a cone beam computed tomography (cbct) with surface optical scan (ios) data that includes patient intraoral situation and the intended restorative planning. 2024-07-26 2024-07-29 Not clear
Alexander Bookbinder, Mislav Bobić, Gregory C Sharp, Lena Nenof. An operator-independent quality assurance system for automatically generated structure sets. Physics in medicine and biology. 2024-07-24. PMID:39047780. radiotherapy contours were propagated from planning ct to daily cone beam ct (cbct) using deformable image registration (dir). 2024-07-24 2024-07-28 Not clear
M C P Kortman, J Jansma, R H Schepers, C H Slump, B J Merema, J Kraeim. A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2024-07-14. PMID:39004536. the accuracy analysis was based on postoperative (cone beam) computed tomography ((cb)ct) data and preoperative 3d planning. 2024-07-14 2024-07-18 Not clear
Poppy Nikou, Anna Thompson, Andrew Nisbet, Sarah Gulliford, Jamie R McClellan. Modelling systematic anatomical uncertainties of head and neck cancer patients during fractionated radiotherapy treatment. Physics in medicine and biology. 2024-07-09. PMID:38981595. intra- patient correspondence between each planning ct scan and on treatment cone beam ct scans was obtained using diffeomorphic deformable image registration. 2024-07-09 2024-07-12 Not clear
Laurits Kaaber, Louise Hauge Matzen, Rubens Spin-Neto, Lars Schrop. Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Clinical oral implants research. 2024-07-06. PMID:38970301. low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: an ex vivo study in human specimens. 2024-07-06 2024-07-12 human
Laurits Kaaber, Louise Hauge Matzen, Rubens Spin-Neto, Lars Schrop. Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Clinical oral implants research. 2024-07-06. PMID:38970301. to evaluate the performance of low-dose cone beam computed tomography (cbct) protocols with regard to linear bone measurements in the posterior mandible for implant planning compared with higher dose protocols. 2024-07-06 2024-07-12 human
Shalini Mundra, Neetha J Shett. A Smile Reimagined: Gummy Smile Resolution with Cutting Edge Method Using Chu's Gauge and Polymethylmethacrylate (PMMA) Bone Cement. Case reports in dentistry. vol 2024. 2024-06-17. PMID:38884011. the entire treatment plan was digitalised using cutting edge methods such as computed tomography (ct), cone beam computed tomography (cbct), and 3d printers for virtual planning of the defect's position, size, and shape. 2024-06-17 2024-06-19 Not clear
Henrik Frisk, Gustav Burström, Juliane Weinzierl, Linda Westernhagen, Florentin Tranchant, Erik Edström, Adrian Elmi-Terande. Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model. Journal of visualized experiments : JoVE. issue 207. 2024-06-10. PMID:38856206. cone beam computerized tomography (cbct) was performed, and a 3d rendering was automatically generated, which was used for the subsequent planning of the pedicle screw placements. 2024-06-10 2024-06-14 Not clear
Jerson Jimmy Palomino-Zorrilla, Nancy Edith Córdova-Limaylla, José C Rosas-Díaz, César F Cayo-Rojas, Luis A Cervantes-Ganoza, Maria E Guerrer. Jawbone quality classification in dental implant planning and placement studies. A scoping review. Journal of International Society of Preventive & Community Dentistry. vol 14. issue 2. 2024-06-03. PMID:38827351. cone beam computed tomography has become an attractive method for implant planning. 2024-06-03 2024-06-05 Not clear
Alejandro Lanis, Alwaleed Helmi, Samuel Akhondi, Adam Hamilton, Bernard Friedlan. Merging Mandibular Virtual Data Sets in Partially Edentulous Patients with a High-level of Scattering on Cone-beam CT Scans: A Technical Report. The International journal of periodontics & restorative dentistry. vol 0. issue 0. 2024-05-31. PMID:38820273. digital implant planning, utilizing the convergence of digital surface scanners, cone beam computer tomography (cbct) scans, and advanced planning software, has transformed dental implantology. 2024-05-31 2024-06-02 Not clear
Shengtao Yang, Junying Li, Quan Yuan, Li Yue, Chenxuan We. Superimposing digital arch scans onto cone beam computed tomography scans with metallic artifacts by applying a radiopaque occlusal registration material: A chairside dental technique. The Journal of prosthetic dentistry. 2024-05-28. PMID:38806339. precise alignment between digital arch scans and cone beam computed tomography (cbct) scans is a crucial step in computer-aided implant planning and placement. 2024-05-28 2024-06-03 Not clear
Sara Elsonbaty, Bahaaeldeen M Elgarba, Rocharles Cavalcante Fontenele, Abdullah Swaity, Reinhilde Jacob. Novel AI-based tool for primary tooth segmentation on CBCT using convolutional neural networks: A validation study. International journal of paediatric dentistry. 2024-05-21. PMID:38769619. primary teeth segmentation on cone beam computed tomography (cbct) scans is essential for paediatric treatment planning. 2024-05-21 2024-05-27 Not clear
Luciano Rivetti, Andrej Studen, Manju Sharma, Jason W Chan, Robert Jera. Uncertainty estimation and evaluation of deformation image registration based convolutional neural networks. Physics in medicine and biology. 2024-05-15. PMID:38749468. our application investigated registration of a treatment planning computed tomography (ct) to follow-up cone beam ct for daily adaptive radiotherapy. main results the hyperparameter tuning of the models showed that there is a trade-off between the reliability of the estimated uncertainty and the accuracy of the deformation. 2024-05-15 2024-05-27 Not clear
Yu Liu, Rui Xie, Lifeng Wang, Hongpeng Liu, Chen Liu, Yimin Zhao, Shizhu Bai, Wenyong Li. Fully automatic AI segmentation of oral surgery-related tissues based on cone beam computed tomography images. International journal of oral science. vol 16. issue 1. 2024-05-08. PMID:38719817. accurate segmentation of oral surgery-related tissues from cone beam computed tomography (cbct) images can significantly accelerate treatment planning and improve surgical accuracy. 2024-05-08 2024-05-27 Not clear
Lambert J Stumpel, Edmond A Bedrossian, Marta Revilla-Leó. Virtual Implant Planning and Surgical Guide for Single Implant Placement Fabricated from a Digital Diagnostic Cast, 2-dimensional Radiographic Imaging, and an Open-source Program: A Dental Technique. The International journal of oral & maxillofacial implants. vol 0. issue 0. 2024-04-12. PMID:38607358. when a cone bean computed tomography scan is not available, this technique eases implant planning procedures and minimize possible surgical complications. 2024-04-12 2024-04-14 Not clear