All Relations between planning and retina cone cell

Publication Sentence Publish Date Extraction Date Species
Yaoqin Xie, Ming Chao, Percy Lee, Lei Xin. Feature-based rectal contour propagation from planning CT to cone beam CT. Medical physics. vol 35. issue 10. 2008-12-09. PMID:18975692. feature-based rectal contour propagation from planning ct to cone beam ct. 2008-12-09 2023-08-12 Not clear
Yaoqin Xie, Ming Chao, Percy Lee, Lei Xin. Feature-based rectal contour propagation from planning CT to cone beam CT. Medical physics. vol 35. issue 10. 2008-12-09. PMID:18975692. the purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (ct) (pct) to cone beam ct (cbct). 2008-12-09 2023-08-12 Not clear
J A Bryant, N A Drage, S Richmon. Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system. Dento maxillo facial radiology. vol 37. issue 7. 2008-12-08. PMID:18812597. as part of an ongoing programme to improve diagnosis and treatment planning relevant to implant placement, orthodontic treatment and dentomaxillofacial surgery, a study has been made of the spatial accuracy and density response of an i-cat, a cone beam ct (cbct) dental imaging system supplied by imaging sciences international inc. 2008-12-08 2023-08-12 Not clear
Ming Chao, Yaoqin Xie, Lei Xin. Auto-propagation of contours for adaptive prostate radiation therapy. Physics in medicine and biology. vol 53. issue 17. 2008-11-13. PMID:18677041. the purpose of this work is to develop an effective technique to automatically propagate contours from planning ct to cone beam ct (cbct) to facilitate cbct-guided prostate adaptive radiation therapy. 2008-11-13 2023-08-12 Not clear
Karsten Østergaard Noe, Baudouin Denis De Senneville, Ulrik Vindelev Elstrøm, Kari Tanderup, Thomas Sangild Sørense. Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy. Acta oncologica (Stockholm, Sweden). vol 47. issue 7. 2008-10-23. PMID:18661435. the other method by cornelius & kanade is tested on a series of six 3d cone beam ct (cbct) data sets and a conventional planning ct data set from a head and neck cancer patient. 2008-10-23 2023-08-12 Not clear
Johan J Pöll, Mischa S Hoogeman, Jean-Briac Prévost, Joost J Nuyttens, Peter C Levendag, Ben J Heijme. Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators. Medical physics. vol 35. issue 6. 2008-09-23. PMID:18649461. to substantially reduce the number of mus, the authors have developed a new planning strategy for combined use of a small and a large cone. 2008-09-23 2023-08-12 Not clear
Antonella Fogliata, Giorgia Nicolini, Eugenio Vanetti, Alessandro Clivio, Peter Winkler, Luca Cozz. The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases. Physics in medicine and biology. vol 53. issue 9. 2008-07-07. PMID:18421117. algorithms investigated were the pencil beam (pbc), the anisotropic analytical algorithm (aaa) and the collapsed cone (cc) from the varian eclipse or philips pinnacle planning system. 2008-07-07 2023-08-12 Not clear
A Suomalainen, T Vehmas, M Kortesniemi, S Robinson, J Peltol. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dento maxillo facial radiology. vol 37. issue 1. 2008-04-10. PMID:18195249. the aim of this study was to evaluate the accuracy of linear measurements obtained with dental cone beam ct (cbct) and multislice ct (msct) by altering radiation doses using pre-operative planning of the placement of oral implants as a model. 2008-04-10 2023-08-12 Not clear
Hans-Joachim Nickenig, Stephan Eitne. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. vol 35. issue 4-5. 2008-01-07. PMID:17576068. reliability of implant placement after virtual planning of implant positions using cone beam ct data and surgical (guide) templates. 2008-01-07 2023-08-12 Not clear
Oliver Koelbl, Thomas Krieger, Ulrich Haedinger, Otto Sauer, Michael Flentj. Influence of calculation algorithm on dose distribution in irradiation of non-small cell lung cancer (NSCLC) collapsed cone versus pencil beam. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 180. issue 12. 2007-10-30. PMID:15592698. the influence of two different calculation algorithms ("pencil beam" [pb] versus "collapsed cone" [cc]) on dose distribution, as well as the dose-volume histograms (dvhs) of the planning target volume (ptv) and the organs at risk was analyzed for irradiation of lung cancer. 2007-10-30 2023-08-12 Not clear
Vanessa Panettieri, Berit Wennberg, Giovanna Gagliardi, Maria Amor Duch, Mercè Ginjaume, Ingmar La. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems. Physics in medicine and biology. vol 52. issue 14. 2007-09-19. PMID:17664607. the mc results were compared with those obtained with three commercial treatment planning systems (tpss), two based on the pencil beam (pb) algorithm, the tms-helax (nucletron, sweden) and eclipse (varian medical system, palo alto, ca), and one based on the collapsed cone algorithm (cc), pinnacle(3) (philips). 2007-09-19 2023-08-12 Not clear
Anthony G Scla. Guidelines for flapless surgery. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. vol 65. issue 7 Suppl 1. 2007-08-21. PMID:17586346. with the introduction of in-office cone beam computed tomography (ct), improved access to conventional ct scanning, and dental implant treatment planning software allowing on-the-spot 3-dimensional evaluations of potential implant sites, the use of "flapless" implant surgery has gained popularity among surgeons. 2007-08-21 2023-08-12 Not clear
Shannon M MacDonald, Salahuddin Ahmad, Stefanos Kachris, Betty J Vogds, Melissa DeRouen, Alicia E Gittleman, Keith DeWyngaert, Maria T Vlachak. Intensity modulated radiation therapy versus three-dimensional conformal radiation therapy for the treatment of high grade glioma: a dosimetric comparison. Journal of applied clinical medical physics. vol 8. issue 2. 2007-07-17. PMID:17592465. specifically, minimum and mean planning target volume cone down doses were 54.52 gy and 61.74 gy for imrt and 50.56 gy and 60.06 gy for 3d-crt (p < or = 0.01). 2007-07-17 2023-08-12 Not clear
James J Closmann, Brian L Schmid. The use of cone beam computed tomography as an aid in evaluating and treatment planning for mandibular cancer. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. vol 65. issue 4. 2007-04-24. PMID:17368377. the use of cone beam computed tomography as an aid in evaluating and treatment planning for mandibular cancer. 2007-04-24 2023-08-12 Not clear
James J Closmann, Brian L Schmid. The use of cone beam computed tomography as an aid in evaluating and treatment planning for mandibular cancer. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. vol 65. issue 4. 2007-04-24. PMID:17368377. in this article we relate the use of cone beam computed tomography (cbct) to image the mandible with less cost and morbidity to the patient and its use in the evaluation and treatment planning of mandibular cancer. 2007-04-24 2023-08-12 Not clear
Christoph Zizelmann, Nils Claudius Gellrich, Marc Christian Metzger, Ralf Schoen, Rainer Schmelzeisen, Alexander Schram. Computer-assisted reconstruction of orbital floor based on cone beam tomography. The British journal of oral & maxillofacial surgery. vol 45. issue 1. 2007-04-03. PMID:16095777. we used a navigation system for computer-assisted preoperative planning based on cone beam tomography with virtual reconstruction to obtain symmetry of the orbit and intraoperative control of virtual contours. 2007-04-03 2023-08-12 Not clear
Christoph Zizelmann, Nils Claudius Gellrich, Marc Christian Metzger, Ralf Schoen, Rainer Schmelzeisen, Alexander Schram. Computer-assisted reconstruction of orbital floor based on cone beam tomography. The British journal of oral & maxillofacial surgery. vol 45. issue 1. 2007-04-03. PMID:16095777. cone beam tomography seems to be suitable for computer-assisted planning in the management of orbital trauma with reduced costs and less radiation. 2007-04-03 2023-08-12 Not clear
G R Bake. Localization: conventional and CT simulation. The British journal of radiology. vol 79 Spec No 1. 2006-11-08. PMID:16980684. the recent implementation of cone beam imaging on simulators has transformed them into three dimensional imaging devices able to produce the data required for complex treatment planning. 2006-11-08 2023-08-12 human
C J Moore, A Amer, T Marchant, J R Sykes, J Davies, J Stratford, C McCarthy, C MacBain, A Henry, P Price, P C William. Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy. The British journal of radiology. vol 79 Spec No 1. 2006-11-08. PMID:16980686. three roles for cone beam tomography in radiotherapy are identified: patient setup in three dimensions (3d), where even low dose cone beam tissue detail is superior to megavoltage imaging; disease targeting where, despite wide field scatter and slow scanning, it is possible to generate images that are suitable for tumour delineation even at challenging sites; adaptive treatment planning, where calibrated cone beam images have been shown to provide sufficient target detail to support "plan of the day" selection and have the potential for planning with bulk corrections. 2006-11-08 2023-08-12 Not clear
M M Aspradakis, H M McCallum, N Wilso. Dosimetric and treatment planning considerations for radiotherapy of the chest wall. The British journal of radiology. vol 79. issue 946. 2006-10-17. PMID:16687464. this work evaluates a collapsed cone (cc) and a pencil beam (pb) convolution model for radiotherapy planning of the chest wall. 2006-10-17 2023-08-12 Not clear