All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Jan Unkelbach, Thomas Bortfeld, David Craft, Markus Alber, Mark Bangert, Rasmus Bokrantz, Danny Chen, Ruijiang Li, Lei Xing, Chunhua Men, Simeon Nill, Dávid Papp, Edwin Romeijn, Ehsan Salar. Optimization approaches to volumetric modulated arc therapy planning. Medical physics. vol 42. issue 3. 2016-05-15. PMID:25735291. a large number of treatment planning studies have evaluated the potential for vmat for different disease sites based on the currently available commercial implementations of vmat planning. 2016-05-15 2023-08-13 Not clear
Jan Unkelbach, Thomas Bortfeld, David Craft, Markus Alber, Mark Bangert, Rasmus Bokrantz, Danny Chen, Ruijiang Li, Lei Xing, Chunhua Men, Simeon Nill, Dávid Papp, Edwin Romeijn, Ehsan Salar. Optimization approaches to volumetric modulated arc therapy planning. Medical physics. vol 42. issue 3. 2016-05-15. PMID:25735291. vmat planning represents a challenging large scale optimization problem. 2016-05-15 2023-08-13 Not clear
Jan Unkelbach, Thomas Bortfeld, David Craft, Markus Alber, Mark Bangert, Rasmus Bokrantz, Danny Chen, Ruijiang Li, Lei Xing, Chunhua Men, Simeon Nill, Dávid Papp, Edwin Romeijn, Ehsan Salar. Optimization approaches to volumetric modulated arc therapy planning. Medical physics. vol 42. issue 3. 2016-05-15. PMID:25735291. in contrast to fluence map optimization in intensity-modulated radiotherapy planning for static beams, vmat planning represents a nonconvex optimization problem. 2016-05-15 2023-08-13 Not clear
Jan Unkelbach, Thomas Bortfeld, David Craft, Markus Alber, Mark Bangert, Rasmus Bokrantz, Danny Chen, Ruijiang Li, Lei Xing, Chunhua Men, Simeon Nill, Dávid Papp, Edwin Romeijn, Ehsan Salar. Optimization approaches to volumetric modulated arc therapy planning. Medical physics. vol 42. issue 3. 2016-05-15. PMID:25735291. in this paper, the authors review the state-of-the-art in vmat planning from an algorithmic perspective. 2016-05-15 2023-08-13 Not clear
Raymond W Chan, Matthew B Podgorsa. Ipsilateral kidney sparing in treatment of pancreatic malignancies using volumetric-modulated arc therapy avoidance sectors. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 3. 2016-05-03. PMID:25524821. the target planning target volume (286.97 ± 85.17 cm(3)) was prescribed to 50.4 gy using avoidance sectors of 30°, 40°, and 50° and then compared with vmat as well as 3d-crt. 2016-05-03 2023-08-13 Not clear
Raymond W Chan, Matthew B Podgorsa. Ipsilateral kidney sparing in treatment of pancreatic malignancies using volumetric-modulated arc therapy avoidance sectors. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 3. 2016-05-03. PMID:25524821. employing avoidance sector angles as a complement to vmat planning can significantly reduce high dose to the ipsilateral kidney while not greatly overdosing other critical organs. 2016-05-03 2023-08-13 Not clear
b' Jin Shen, Edward Bender, Ravindra Yaparpalvi, Hsiang-Chi Kuo, Amar Basavatia, Linda Hong, William Bodner, Madhur K Garg, Shalom Kalnicki, Wolfgang A Tom\\xc3\\xa. An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT). Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 3. 2016-05-03. PMID:25605507.' an efficient and simple class solution is proposed for hippocampal-avoidance whole-brain radiation therapy (ha-wbrt) planning using the volumetric arc therapy (vmat) delivery technique following the nrg oncology protocol nrg-cc001 treatment planning guidelines. 2016-05-03 2023-08-13 Not clear
b' Jin Shen, Edward Bender, Ravindra Yaparpalvi, Hsiang-Chi Kuo, Amar Basavatia, Linda Hong, William Bodner, Madhur K Garg, Shalom Kalnicki, Wolfgang A Tom\\xc3\\xa. An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT). Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 3. 2016-05-03. PMID:25605507.' an efficient and simple planning class solution for ha-wbrt using vmat has been developed that allows all protocol constraints of nrg-cc001 to be met. 2016-05-03 2023-08-13 Not clear
S Rana, S Pokhare. Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films. The Gulf journal of oncology. vol 1. issue 14. 2016-04-23. PMID:23996869. the development of advanced radiation treatment techniques such as intensity modulated radiation therapy (imrt) and volumetric intensity modulated arc therapy (vmat) require more accurate dose calculation algorithms within the treatment planning systems (tps) considering that the human body is composed of tissues of widely differing radiological properties and the characteristics of a therapeutic radiation treatment beam along a heterogeneous path will be different. 2016-04-23 2023-08-12 human
Sarah Ghandour, Oscar Matzinger, Marc Pachou. Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer. Journal of applied clinical medical physics. vol 16. issue 3. 2016-03-21. PMID:26103500. the purpose of this work is to evaluate the volumetric-modulated arc therapy (vmat) multicriteria optimization (mco) algorithm clinically available in the raystation treatment planning system (tps) and its ability to reduce treatment planning time while providing high dosimetric plan quality. 2016-03-21 2023-08-13 Not clear
Mostafa Farzin, Michael Molls, Sabrina Astner, Ina-Christine Rondak, Markus Oechsne. Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 191. issue 12. 2016-03-21. PMID:26340939. in 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (vmat): simultaneous integrated boost (sib) vs. sequential boost (seb). 2016-03-21 2023-08-13 Not clear
Yvonne Dzierma, Norbert Licht, Ian Norton, Frank Nuesken, Christian Rübe, Jochen Fleckenstei. VMAT to arclet plan conversion in a treatment planning system : Feasibility and dosimetric relationship between VMAT, arclet, and stationary fields. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 191. issue 12. 2016-03-21. PMID:26346775. vmat to arclet plan conversion in a treatment planning system : feasibility and dosimetric relationship between vmat, arclet, and stationary fields. 2016-03-21 2023-08-13 Not clear
Magdalena Bazalova-Carter, Bradley Qu, Bianey Palma, Björn Hårdemark, Elin Hynning, Christopher Jensen, Peter G Maxim, Billy W Lo. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans. Medical physics. vol 42. issue 5. 2016-03-14. PMID:25979053. treatment planning for radiotherapy with very high-energy electron beams and comparison of vhee and vmat plans. 2016-03-14 2023-08-13 Not clear
Jelena Lukovic, Nikhilesh Patil, David D'souza, Barbara Millman, Brian P Yaremko, Eric Leung, Frances Whiston, George Hajdok, Eugene Won. Intensity-Modulated Radiation Therapy Versus 3D Conformal Radiotherapy for Postoperative Gynecologic Cancer: Are They Covering the Same Planning Target Volume? Cureus. vol 8. issue 1. 2016-03-14. PMID:26973802. this study compares dosimetric parameters of planning target volume (ptv) coverage and organs at risk (oar) sparing when postoperative radiotherapy for gynecologic cancers is delivered using volumetric modulated arc therapy (vmat) versus a four-field (4fld) box technique. 2016-03-14 2023-08-13 Not clear
Kalevi Kairemo, Nigora Rasulova, Timo Kiljunen, Kaarina Partanen, Aki Kangasmäki, Timo Joensu. PET/CT Dose Planning for Volumetric Modulated Arc Radiation Therapy (VMAT) -Comparison with Conventional Approach in Advanced Prostate Cancer Patients. Current radiopharmaceuticals. vol 8. issue 1. 2016-02-16. PMID:25882786. pet/ct dose planning for volumetric modulated arc radiation therapy (vmat) -comparison with conventional approach in advanced prostate cancer patients. 2016-02-16 2023-08-13 Not clear
Jun Shang, Wei Kong, Yan-yang Wang, Zhe Ding, Gang Yan, Hong Zh. VMAT planning study in rectal cancer patients. Radiation oncology (London, England). vol 9. 2016-01-28. PMID:25319073. vmat planning study in rectal cancer patients. 2016-01-28 2023-08-13 Not clear
Taeryool Koo, Jin-Beom Chung, Keun-Yong Eom, Jin-Yong Seok, In-Ah Kim, Jae-Sung Ki. Dosimetric effects of the acuros XB and anisotropic analytical algorithm on volumetric modulated arc therapy planning for prostate cancer using an endorectal balloon. Radiation oncology (London, England). vol 10. 2016-01-28. PMID:25890071. to compare the dosimetric effects of acuros xb (axb) and anisotropic analytical algorithm (aaa) on volumetric modulated arc therapy (vmat) planning for postoperative prostate cancer patients irradiated using an endorectal balloon (erb). 2016-01-28 2023-08-13 Not clear
Hojin Kim, Ruijiang Li, Rena Lee, Lei Xin. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization. Physics in medicine and biology. vol 60. issue 5. 2016-01-19. PMID:25675281. the proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional vmat and sport planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (hn) cases with a single and multiple targets). 2016-01-19 2023-08-13 Not clear
V V Glebovskaya, S I Tkachev, A O Rasulov, V F Tsaryuk, S S Gordeev, M Yu Fedyanin, V A Aliev, Z Z Mamedly, D V Kuzmichev, O P Trofimova, T N Borisova, I P Yazhgunovic. [Results of complex treatment of patients with squamous cell carcinoma of the anal canal using advanced radiotherapy technologies]. Voprosy onkologii. vol 61. issue 4. 2016-01-07. PMID:26571840. the use of modem linear electron accelerators and systems of computer dosimetric planning to create a 3d program of isodose distribution, diagnostic devices (computed tomography and magnetic resonance imaging) as well as a number of other conditions permit accurate summarizing of proposed dose, reducing of absorbed dose to critical structures, diminishing unplanned interruptions in chemoradiotherapy course by means of modern technologies of conformal radiotherapy (3d crt, imrt, vmat). 2016-01-07 2023-08-13 Not clear
Ruggero Ruggieri, Stefania Naccarato, Pavel Stavrev, Nadejda Stavreva, Sergio Fersino, Niccolò Giaj Levra, Rosario Mazzola, Pietro Mancosu, Marta Scorsetti, Filippo Along. Volumetric-modulated arc stereotactic body radiotherapy for prostate cancer: dosimetric impact of an increased near-maximum target dose and of a rectal spacer. The British journal of radiology. vol 88. issue 1054. 2015-12-29. PMID:26235142. in volumetric-modulated arc therapy (vmat) prostate stereotactic body radiotherapy (sbrt), dose coverage of the planning target volume (ptv) becomes challenging when the sparing of rectum, bladder and urethra is strictly pursued. 2015-12-29 2023-08-13 Not clear