All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Gregory P Penoncello, George X Din. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 41. issue 1. 2016-12-13. PMID:26764180. the eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with vmat and static-field imrt. 2016-12-13 2023-08-13 Not clear
Hao Ga. Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization. Physics in medicine and biology. vol 61. issue 7. 2016-12-13. PMID:26987680. for the treatment planning during intensity modulated radiation therapy (imrt) or volumetric modulated arc therapy (vmat), beam fluence maps can be first optimized via fluence map optimization (fmo) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparing the organs-at-risk, and then segmented into deliverable mlc apertures via leaf or arc sequencing algorithms. 2016-12-13 2023-08-13 Not clear
Barbara Dobler, Amine Khemissi, Tina Obermeier, Matthias G Hautmann, Zaira Katsilieri, Oliver Kölb. Re-irradiating spinal column metastases using IMRT and VMAT with and without flattening filter - a treatment planning study. Radiation oncology (London, England). vol 11. 2016-11-03. PMID:26932561. re-irradiating spinal column metastases using imrt and vmat with and without flattening filter - a treatment planning study. 2016-11-03 2023-08-13 Not clear
Motoharu Sasaki, Hitoshi Ikushima, Masahide Tominaga, Takeshi Kamomae, Taro Kishi, Masataka Oita, Masafumi Harad. Dose impact of rectal gas on prostatic IMRT and VMAT. Japanese journal of radiology. vol 33. issue 12. 2016-10-31. PMID:26573828. in this study, we compared the dose impact of the heterogeneity caused by rectal gas using two methods of treatment planning for intensity-modulated radiotherapy (imrt) and volumetric-modulated arc therapy (vmat). 2016-10-31 2023-08-13 Not clear
Thierry Gevaert, Femke Steenbeke, Luca Pellegri, Benedikt Engels, Nicolas Christian, Marie-Thérèse Hoornaert, Dirk Verellen, Carine Mitine, Mark De Ridde. Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm? Radiation oncology (London, England). vol 11. 2016-10-24. PMID:26831367. to investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (dca), and to benchmark it against the well-established multiple isocenter dca (midca) and volumetric modulated arc therapy (vmat) approaches. 2016-10-24 2023-08-13 Not clear
L Nithya, N Arunai Nambi Raj, Sasikumar Rathinamuthu, Manish Bhushan Pande. Analyzing the performance of the planning system by use of AAPM TG 119 test cases. Radiological physics and technology. vol 9. issue 1. 2016-10-19. PMID:26141766. our objective in this study was to create aapm tg 119 test plans for intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) in the monaco planning system. 2016-10-19 2023-08-13 Not clear
Marie Huss, Pierre Barsoum, Ernest Dodoo, Georges Sinclair, Iuliana Toma-Das. Fractionated SRT using VMAT and Gamma Knife for brain metastases and gliomas--a planning study. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699547. fractionated srt using vmat and gamma knife for brain metastases and gliomas--a planning study. 2016-09-28 2023-08-13 Not clear
Marie Huss, Pierre Barsoum, Ernest Dodoo, Georges Sinclair, Iuliana Toma-Das. Fractionated SRT using VMAT and Gamma Knife for brain metastases and gliomas--a planning study. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699547. another option for fractionated srt is advanced planning and delivery using linacs and volumetric modulated arc therapy (vmat). 2016-09-28 2023-08-13 Not clear
Jarkko Juhani Ojala, Mika Kapane. Quantification of dose differences between two versions of Acuros XB algorithm compared to Monte Carlo simulations--the effect on clinical patient treatment planning. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699576. both versions of the axb were part of varian's eclipse clinical treatment planning system and treatment plans for 10 patients were created using intensity-modulated radiotherapy (imrt) and volumetric-modulated arc radiotherapy (vmat). 2016-09-28 2023-08-13 Not clear
Jin-Beom Chung, Jae-Sung Kim, Keun-Yong Eom, In-Ah Kim, Sang-Won Kang, Jeong-Woo Lee, Jin-Young Kim, Tae-Suk Su. Comparison of VMAT-SABR treatment plans with flattening filter (FF) and flattening filter-free (FFF) beam for localized prostate cancer. Journal of applied clinical medical physics. vol 16. issue 6. 2016-09-28. PMID:26699585. sabr plans using vmat with two full arcs were optimized in the eclipse treatment planning system. 2016-09-28 2023-08-13 Not clear
Muhammad Isa Khan, Runqing Jiang, Alexander Kiciak, Jalil Ur Rehman, Muhammad Afzal, James C L Cho. Dosimetric and radiobiological characterizations of prostate intensity-modulated radiotherapy and volumetric-modulated arc therapy: A single-institution review of ninety cases. Journal of medical physics. vol 41. issue 3. 2016-09-21. PMID:27651562. characterizations of dosimetry and radiobiological variation in prostate were determined based on treatment plans of 40 prostate imrt patients (planning target volume = 77.8-335 cm(3)) and 50 vmat patients (planning target volume = 120-351 cm(3)) treated before and after 2013, respectively. 2016-09-21 2023-08-13 Not clear
Muhammad Isa Khan, Runqing Jiang, Alexander Kiciak, Jalil Ur Rehman, Muhammad Afzal, James C L Cho. Dosimetric and radiobiological characterizations of prostate intensity-modulated radiotherapy and volumetric-modulated arc therapy: A single-institution review of ninety cases. Journal of medical physics. vol 41. issue 3. 2016-09-21. PMID:27651562. both imrt and vmat plans used the same dose-volume criteria in the inverse planning optimization. 2016-09-21 2023-08-13 Not clear
Muhammad Isa Khan, Runqing Jiang, Alexander Kiciak, Jalil Ur Rehman, Muhammad Afzal, James C L Cho. Dosimetric and radiobiological characterizations of prostate intensity-modulated radiotherapy and volumetric-modulated arc therapy: A single-institution review of ninety cases. Journal of medical physics. vol 41. issue 3. 2016-09-21. PMID:27651562. dose-volume histogram, mean doses of target and normal tissues (rectum, bladder and femoral heads), dose-volume points (d99% of planning target volume; d30%, d50%, v30 gy and v35 gy of rectum and bladder; d5%, v14 gy, v22 gy of femoral heads), conformity index (ci), homogeneity index (hi), gradient index (gi), prostate tumor control probability (tcp), and rectal normal tissue complication probability (ntcp) based on the lyman-burman-kutcher algorithm were calculated for each imrt and vmat plan. 2016-09-21 2023-08-13 Not clear
Norbert Klippel, Michael Schmücking, Dario Terribilini, Andreas Geretschläger, Daniel M Aebersold, Peter Manse. Improved VMAT planning for head and neck tumors with an advanced optimization algorithm. Zeitschrift fur medizinische Physik. vol 25. issue 4. 2016-09-19. PMID:26071076. improved vmat planning for head and neck tumors with an advanced optimization algorithm. 2016-09-19 2023-08-13 Not clear
Jia-Yang Lu, Ji-Yong Zhang, Mei Li, Michael Lok-Man Cheung, Yang-Kang Li, Jing Zheng, Bao-Tian Huang, Wu-Zhe Zhan. A simple optimization approach for improving target dose homogeneity in intensity-modulated radiotherapy for sinonasal cancer. Scientific reports. vol 5. 2016-09-19. PMID:26497620. we compared the plan qualities, total planning time and monitor units (mus) among the initial, bdc, ldc imrt plans and volumetric modulated arc therapy (vmat) plans. 2016-09-19 2023-08-13 Not clear
Jia-Yang Lu, Ji-Yong Zhang, Mei Li, Michael Lok-Man Cheung, Yang-Kang Li, Jing Zheng, Bao-Tian Huang, Wu-Zhe Zhan. A simple optimization approach for improving target dose homogeneity in intensity-modulated radiotherapy for sinonasal cancer. Scientific reports. vol 5. 2016-09-19. PMID:26497620. the planning of bdc, ldc imrt and vmat required 30, 59 and 58 minutes on average, respectively. 2016-09-19 2023-08-13 Not clear
Hongfu Zhao, Mingyuan He, Guanghui Cheng, Dongmei Han, Ning Wu, Dan Shi, Zhipeng Zhao, Jianxue Ji. A comparative dosimetric study of left sided breast cancer after breast-conserving surgery treated with VMAT and IMRT. Radiation oncology (London, England). vol 10. 2016-09-08. PMID:26577189. this study compared vmat and imrt plans for intact breast radiotherapy for left sided breast cancer and evaluated the irradiated dose of planning target volume and oars, especially focusing on heart and coronary artery. 2016-09-08 2023-08-13 Not clear
Anders T Hansen, Slavka Lukacova, Yasmin Lassen-Ramshad, Jørgen B Peterse. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 4. 2016-09-07. PMID:26002123. all the new planning techniques increased the number of monitor units (mu) used-the noncoplanar imrt technique by 99%, the coplanar imrt technique by 122%, and the vmat technique by 26%-causing concern for leak radiation. 2016-09-07 2023-08-13 Not clear
Mike Dickey, Wilson Roa, Suzanne Drodge, Sunita Ghosh, Brad Murray, Rufus Scrimger, Zsolt Gabo. A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 4. 2016-09-07. PMID:26027510. treatments of 23 patients previously treated with msf of 48gy to 95% of the planning target volume (ptv) in 4 fractions were replanned using ca and vmat techniques. 2016-09-07 2023-08-13 Not clear
Mike Dickey, Wilson Roa, Suzanne Drodge, Sunita Ghosh, Brad Murray, Rufus Scrimger, Zsolt Gabo. A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 40. issue 4. 2016-09-07. PMID:26027510. both ca and vmat planning showed significant dosimetric improvements and shorter treatment times over those of msf. 2016-09-07 2023-08-13 Not clear