All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Vishwadeep Mishra, Shwetima Chaudhary, Prarabdh Singh, Laxman Pandey, Archana Pandey, Rachita Chatterje. Comparing Dosimetry of Heart and Left Anterior Descending Artery Exposure in Carcinoma Esophagus Patients: Volumetric Arc Therapy Versus Intensity-Modulated Radiotherapy. Cureus. vol 16. issue 8. 2024-09-30. PMID:39347339. vmat planning involved a two-phase approach: 45 gy in 25 fractions followed by a boost of 5.4 gy in three fractions. 2024-09-30 2024-10-02 Not clear
M Zadnorouzi, S M M Abtah. Artificial intelligence (AI) applications in improvement of IMRT and VMAT radiotherapy treatment planning processes: A systematic review. Radiography (London, England : 1995). vol 30. issue 6. 2024-09-25. PMID:39321595. artificial intelligence (ai) applications in improvement of imrt and vmat radiotherapy treatment planning processes: a systematic review. 2024-09-25 2024-09-28 Not clear
Akseli Leino, Janne Heikkilä, Tuomas Virén, Juuso T J Honkanen, Jan Seppälä, Henri Korkalaine. Deep learning-based prediction of the dose-volume histograms for volumetric modulated arc therapy of left-sided breast cancer. Medical physics. 2024-09-18. PMID:39291645. deep learning has the potential to significantly simplify the trial-and-error process involved in inverse planning required by modern treatment techniques such as volumetric modulated arc therapy (vmat). 2024-09-18 2024-09-20 Not clear
Anthony Magliari, Ryan Clark, Lesley Rosa, Sushil Beriwa. HN-SIB-BPI: A single click, sub-site specific, dosimetric scorecard tuned RapidPlan model created from a foundation model for treating head and neck with bilateral neck. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-09-14. PMID:39277451. to develop a knowledge based planning (kbp) model for creating quantifiably high quality vmat treatment plans in a single click for head and neck cases treated simultaneous integrated boost (sib) with bilateral parotid involvement (bpi) where both parotids are near, abutting or partially overlapping target volume. 2024-09-14 2024-09-18 Not clear
Savino Cilla, Gabriella Macchia, Paolo Bonome, Donato Pezzulla, Carmela Romano, Mariangela Boccardi, Pietro Viola, Erika Galietta, Costanza M Donati, Alessio G Morganti, Francesco Deodat. Automated single-isocenter stereotactic body radiotherapy for multiple metastases from breast cancer: A case study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-09-12. PMID:39266381. sbrt with mono isocentric vmat planning represents the recommended approach to simultaneously treat multiple lesions in close proximity in the thoracic district. 2024-09-12 2024-09-15 Not clear
Mahmoud H Abdelgawad, Ahmed A Eldib, Tamer M Elsayed, Cm Charlie M. Investigation of the Linear accelerator low dose rate mode for pulsed low-dose-rate radiotherapy delivery. Biomedical physics & engineering express. 2024-08-27. PMID:39191263. all cases passed our gamma analysis with an average passing rate of 99.00% ± 0.48%. conclusion: the study showed the applicability of planning pulsed vmat using eclipse and its successful delivery on our elekta linac. 2024-08-27 2024-08-30 Not clear
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. the aim of this work was to evaluate the conformity of intensity-modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat), and verify the accuracy of the planning and delivery system used in this work based on the aapm tg-119 protocol. 2024-08-17 2024-08-20 Not clear
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. the eclipse 13.6 treatment planning system (tps) was used to plan the tg-119 test suite, which included four test cases: multitarget, prostate, head/neck, and c-shape for imrt and vmat techniques with 6 mv and 10 mv acceleration voltages. 2024-08-17 2024-08-20 Not clear
Dang Thi Minh Tam, Phan Long Ho, Phan Quoc Uy, Nguyen Trung Hieu, Vo Tan Linh, Nguyen Thi Hoa, Nguyen Thi The Lam, Bui Thi Thuy Nga, Truong Huu Thanh, Tran Thien Thanh, Chau Van Ta. Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol. Radiation and environmental biophysics. 2024-08-17. PMID:39153061. the planning results showed that imrt is more conformal than vmat in certain cases. 2024-08-17 2024-08-20 Not clear
Tomasz Piotrowski, Adam Ryczkowski, Petros Kalendralis, Marcin Adamczewski, Piotr Sadowski, Barbara Bajon, Marta Kruszyna-Mochalska, Agata Jodd. Forecasting model for qualitative prediction of the results of patient-specific quality assurance based on planning and complexity metrics and their interrelations. Pilot study. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 29. issue 3. 2024-08-15. PMID:39144260. the purpose was to analyse the interrelations between planning and complexity metrics and gamma passing rates (gprs) obtained from vmat treatments and build the forecasting models for qualitative prediction (qd) of gprs results. 2024-08-15 2024-08-17 Not clear
Minmin Qiu, Jiajian Zhong, Zhenhua Xiao, Yongjin Den. From plan to delivery: Machine learning based positional accuracy prediction of multi-leaf collimator and estimation of delivery effect in volumetric modulated arc therapy. Journal of applied clinical medical physics. 2024-07-20. PMID:39031794. we comprehensively analyzed factors that may affect mlc positional accuracy in vmat, and constructed a model to predict mlc positional deviation and estimate planning delivery quality according to the vmat plans before delivery. 2024-07-20 2024-07-24 Not clear
Riley C Tegtmeier, Edward L Clouser, Brady S Laughlin, Diego A Santos Toesca, Mattison J Flakus, Sara Bashir, Christopher J Kutyreff, Dean Hobbis, Daniel P Harrington, Jennifer L Smetanick, Nathan Y Yu, Carlos E Vargas, Sarah E James, Jean-Claude M Rwigema, Yi Ron. Evaluation of knowledge-based planning models for male pelvic CBCT-based online adaptive radiotherapy on conventional linear accelerators. Journal of applied clinical medical physics. 2024-07-20. PMID:39031902. to assess the practicality of employing a commercial knowledge-based planning tool (rapidplan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (vmat) plans on iterative cone-beam computed tomography (icbct) datasets. 2024-07-20 2024-07-24 Not clear
Takashi Hanada, Junichi Fukada, Yutaka Shiraishi, Kayo Yoshida, Naoya Sakanoue, Kohei Oguma, Toshio Ohashi, Naoyuki Shigemats. A rare instance of latent systematic error in volumetric-modulated arc therapy with field-extended multi-isocentre irradiation leading to a serious dose-delivery accident. BJR case reports. vol 10. issue 4. 2024-07-19. PMID:39027402. volumetric-modulated arc therapy (vmat) with field-extended multi-isocentre irradiation (vmat-femii) is an effective irradiation technique, particularly for large planning target volumes in the craniocaudal direction. 2024-07-19 2024-07-21 Not clear
Jyotiman Nath, Gautam Sarma, Shachindra Goswami, Shashi Bhushan Sharma, Pranjal Goswami, Apurba Kumar Kalit. Split X-Jaw techniques of volumetric modulated arc radiotherapy in nasopharyngeal cancer: A dosimetric comparison. Journal of cancer research and therapeutics. vol 20. issue 3. 2024-07-18. PMID:39023580. the current study aims to compare the split x-jaw planning technique of volumetric modulated arc radiotherapy (vmat) with the traditional open and limited jaw techniques of vamt in nasopharyngeal carcinoma treatment. 2024-07-18 2024-07-20 Not clear
Antonella Fogliata, Hester Burger, Annemari Groenewald, Lydia Punt, Jeannette Parkes, Luca Cozz. Intensity Modulated Therapy for Patients With Breast Cancer. Practical Guidelines and Tips for an Effective Treatment Planning Strategy. Advances in radiation oncology. vol 9. issue 8. 2024-07-12. PMID:38993192. practical guidelines and tips for effective and robust radiation therapy treatment planning for patients with breast cancer are addressed for fixed-field intensity modulated radiation therapy (imrt) or volumetric modulated arc therapy (vmat) techniques. 2024-07-12 2024-07-14 Not clear
Peng Zhou, Jia Luo, Xiaona Su, Chuan Che. The effect of Inc parameter on VMAT radiotherapy plans quality for rectal cancer using Monaco TPS. Journal of applied clinical medical physics. 2024-06-26. PMID:38923699. to investigate the effect of the increment of gantry angle (inc) parameter setting of the monaco treatment planning system (monaco tps) on the dosimetry and quality parameters of the volumetric modulated arc therapy (vmat) program for rectal cancer. 2024-06-26 2024-06-29 Not clear
Chia-Hui Lin, Jenny Que, Sheng-Yow H. HyperArcTM volumetric modulated arc therapy for hypopharyngeal cancer with solitary recurrence in the cervical vertebra: A case report and literature review. Medicine. vol 103. issue 23. 2024-06-07. PMID:38847726. the new hyperarctm vmat (ha-vmat) planning approach reportedly has better target coverage, higher conformity, and can spare normal organs compared to conventional vmat; however, research on recurrent head and neck cancers is limited. 2024-06-07 2024-06-10 Not clear
Jessica Scholey, Tomi Nano, Kamal Singhrao, Osama Mohammad, Lisa Singer, Peder Eric Zufall Larson, Martina Descovic. Linac- and CyberKnife-based MRI-only treatment planning of prostate SBRT using an optimized synthetic CT calibration curve. Journal of applied clinical medical physics. 2024-06-05. PMID:38837851. the goals of this work were to develop a sct calibration curve using patient data acquired on a clinically commissioned ct scanner and assess for cyberknife- and volumetric modulated arc therapy (vmat)-based mr-only treatment planning of prostate sbrt. 2024-06-05 2024-06-08 Not clear
Zainab Alsaihaty, Hanani Abdul Manan, Akmal Sabarudin, Noorazrul Yahy. Hybrid Treatment Planning for Chest Wall Irradiation Utilizing Three-Dimensional Conformal Radiotherapy (3DCRT), Intensity-Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT): A Systematic Review. Cureus. vol 16. issue 5. 2024-06-04. PMID:38832195. hybrid treatment planning for chest wall irradiation utilizing three-dimensional conformal radiotherapy (3dcrt), intensity-modulated radiation therapy (imrt), and volumetric modulated arc therapy (vmat): a systematic review. 2024-06-04 2024-06-06 Not clear
Niketa Thakur, Nancy Bansal, Meena Sudan, Abhishek Sharm. Optimising craniospinal irradiation for medulloblastoma: a dosimetric comparison of two VMAT planning methods. Ecancermedicalscience. vol 18. 2024-05-23. PMID:38774570. optimising craniospinal irradiation for medulloblastoma: a dosimetric comparison of two vmat planning methods. 2024-05-23 2024-05-27 Not clear