All Relations between planning and mr

Publication Sentence Publish Date Extraction Date Species
Helgasoni, Chandna. MR arthrography of the ankle Magnetic resonance imaging clinics of North America. vol 6. issue 4. 2019-11-20. PMID:9799863. mr arthrography of the ankle also aids in preoperative planning and in differentiating among other entities that can present as ankle instability. 2019-11-20 2023-08-12 Not clear
Sandler, Ohl, Quint, Bre. Determining Local-Regional Extension of Prostate Cancer. Seminars in radiation oncology. vol 3. issue 3. 2019-11-20. PMID:10717068. however, ct is useful for radiotherapeutic treatment planning mr may provide better local disease assessment than trus, but trus is conducive to directed biospy of abnormalities. 2019-11-20 2023-08-12 Not clear
Ando, Fukatsu, Ishigaki, Endo, Miyazak. Intramammary Extension of Breast Cancer: Diagnosis with MR Mammography. Breast cancer (Tokyo, Japan). vol 5. issue 3. 2019-11-20. PMID:11091661. purpose: intramammary extension of breast cancer was investigated using contrast-enhanced magnetic resonance (mr) imaging by comparing mr findings with the histopathology of specimens used for pretreatment planning. 2019-11-20 2023-08-12 Not clear
Ando, Fukatsu, Ishigaki, Endo, Miyazak. Intramammary Extension of Breast Cancer: Diagnosis with MR Mammography. Breast cancer (Tokyo, Japan). vol 5. issue 3. 2019-11-20. PMID:11091661. mr imaging could be useful for the pretreatment planning for patients with breast cancer. 2019-11-20 2023-08-12 Not clear
Suzanne E. Anderson, Norman Y. Otsuka, Lynne S. Steinbac. MR Imaging of Pediatric Elbow Trauma. Seminars in musculoskeletal radiology. vol 2. issue 2. 2019-11-20. PMID:11387101. the multiplanar capability of mr allows for good preoperative planning to delineate fragment displacement. 2019-11-20 2023-08-12 Not clear
Xiang Li, Pengpeng Zhang, Ronald Brisman, Gerald Kutche. Use of simulated annealing for optimization of alignment parameters in limited MRI acquisition volumes of the brain. Medical physics. vol 32. issue 7Part1. 2019-11-20. PMID:28493570. the mr images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the second treatment planning image. 2019-11-20 2023-08-13 Not clear
L N Baldwin, K Wachowicz, B G Fallon. Sci-Fri AM: YIS-01: Comprehensive MR distortion correction: Phantom validation and in-vivo application. Medical physics. vol 35. issue 7Part3. 2019-11-20. PMID:28512908. mr images provide excellent diagnostic information; however, their treatment planning utility is limited due to geometric uncertainties from both system and patient related sources. 2019-11-20 2023-08-13 Not clear
L N Baldwin, K Wachowicz, B G Fallon. Sci-Fri AM: YIS-01: Comprehensive MR distortion correction: Phantom validation and in-vivo application. Medical physics. vol 35. issue 7Part3. 2019-11-20. PMID:28512908. despite this concern, interest in developing mr-based treatment planning protocols is on the rise because of the ease with which clinically relevant structures can be identified in mr. 2019-11-20 2023-08-13 Not clear
T Stanescu, C Kirkby, H Jans, K Wachowicz, S Rathee, M Carlone, B Murray, G Fallon. Sci-Fri PM: Planning-02: MRI-based radiation treatment planning for an MRI-linac system. Medical physics. vol 35. issue 7Part3. 2019-11-20. PMID:28512909. for such a system, the radiation treatment planning procedure is expected to rely on the mr images only, i.e. 2019-11-20 2023-08-13 Not clear
M Lamey, M Carlone, H Alasti, J P Bissonnette, J Borg, S Breen, C Coolens, R Heaton, M Islam, M van Proojen, M Sharpe, T Stanescu, D Jaffra. Poster - Thur Eve - 05: Safety systems and failure modes and effects analysis for a magnetic resonance image guided radiation therapy system. Medical physics. vol 39. issue 7Part2. 2019-11-20. PMID:28516558. the mr images will be registered to a planning image and used for image guidance. 2019-11-20 2023-08-13 Not clear
J Korhonen, M Kapanen, J Keyriläinen, T Seppälä, L Tuomikoski, M Tenhune. SU-E-J-54: Bone Detection in MR Images and Absorbed Dose in a Material Behind Bones in Radiotherapy. Medical physics. vol 39. issue 6Part6. 2019-11-20. PMID:28517612. to determine whether bones could be localized accurately by using mr images only in radiotherapy treatment planning. 2019-11-20 2023-08-13 Not clear
U Ueda, J Chen, I Hsu, G Reed, J Poulio. SU-E-J-94: Investigating the Use of Deformable Algorithms to Register MR Images Acquired with and Without an Endo-Rectal Coil. Medical physics. vol 39. issue 6Part7. 2019-11-20. PMID:28519791. we investigate the performance of deformable registration algorithms to deform mr images acquired with an endo-rectal coil to images acquired without a coil for hdr brachytherapy planning. 2019-11-20 2023-08-13 Not clear
T Stanescu, D Jaffra. Technical Note: Harmonic analysis applied to MR image distortion fields specific to arbitrarily shaped volumes. Medical physics. 2019-11-20. PMID:29799634. mr images need to consistently show high spatial accuracy to facilitate rt-specific tasks such as treatment planning and in-room guidance. 2019-11-20 2023-08-13 Not clear
Patrik Brynolfsson, Jan Axelsson, August Holmberg, Joakim H Jonsson, David Goldhaber, Yiqiang Jian, Fredrik Illerstam, Mathias Engström, Björn Zackrisson, Tufve Nyhol. Technical Note: Adapting a GE SIGNA PET/MR scanner for radiotherapy. Medical physics. 2019-11-20. PMID:29862522. the aim of this work was to adapt a ge signa pet/mr scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (snr) of the mr images, and the accuracy of the pet attenuation correction. 2019-11-20 2023-08-13 Not clear
Michael F Barbaro, Kelsi Chesney, Daniel R Kramer, Spencer Kellis, Terrance Peng, Zack Blumenfeld, Angad S Gogia, Morgan B Lee, Janet Greenwood, George Nune, Laura A Kalayjian, Christianne N Heck, Charles Y Liu, Brian Le. Dual responsive neurostimulation implants for epilepsy. Journal of neurosurgery. 2019-11-20. PMID:30684944. implantation can be done successfully, without telemetry interference, using proper surgical planning and neurostimulator positioning.trajectories for the depth leads were planned using neuronavigation with ct and mr imaging. 2019-11-20 2023-08-13 Not clear
Daniel Umansky, Benjamin W Corn, Ido Strauss, Natan Shtraus, Shlomi Constantini, Vladimir Frolov, Shimon Maimon, Andrew A Kanne. Combined treatment approach to cerebral arteriovenous malformation in pediatric patients: stereotactic radiosurgery to partially Onyx-embolized AVM. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. vol 34. issue 11. 2019-11-15. PMID:29882061. however, the use of onyx causes significant distortion of the mr and ct images, which must be accounted for in any radiation treatment planning predicated on ct and mri. 2019-11-15 2023-08-13 Not clear
Alexander T Mazal, Oganes Ashikyan, Jonathan Cheng, Lu Q Le, Avneesh Chhabr. Diffusion-weighted imaging and diffusion tensor imaging as adjuncts to conventional MRI for the diagnosis and management of peripheral nerve sheath tumors: current perspectives and future directions. European radiology. vol 29. issue 8. 2019-11-15. PMID:30535638. diffusion-weighted mr imaging (dwi) serves as a useful tool in the evaluation and management of pnsts by providing functional information regarding the degree of diffusion, while diffusion tensor imaging (dti) aids in determining the directional information of predominant diffusion and has been shown to be particularly useful for pre-operative planning of these tumors by delineating healthy and pathologic fascicles. 2019-11-15 2023-08-13 Not clear
Y Lei, H K Shu, S Tian, T Wang, T Liu, H Mao, H Shim, W J Curran, X Yan. Pseudo CT Estimation using Patch-based Joint Dictionary Learning. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. vol 2018. 2019-10-29. PMID:30441499. magnetic resonance (mr) simulators have recently gained popularity; it avoids the unnecessary radiation exposure associated with computed tomography (ct) when used for radiation therapy planning. 2019-10-29 2023-08-13 Not clear
Ammar A Chaudhry, Sohaib Naim, Maryam Gul, Abbas Chaudhry, Mike Chen, Rahul Jandial, Behnam Badi. Utility of Preoperative Blood-Oxygen-Level-Dependent Functional MR Imaging in Patients with a Central Nervous System Neoplasm. Radiologic clinics of North America. vol 57. issue 6. 2019-10-14. PMID:31582044. functional mr (fmr) imaging can offer a unique insight into preoperative planning for central nervous system (cns) neoplasms by identifying areas of the brain effected or spared by the neoplasm. 2019-10-14 2023-08-13 Not clear
Nelson Moussazadeh, Linton T Evans, Roxana Grasu, Laurence D Rhines, Claudio E Tatsu. Laser interstitial thermal therapy of the spine: technical aspects. Neurosurgical focus. vol 44. issue VideoSuppl2. 2019-10-07. PMID:29570390. the safe and effective use of this technology requires meticulous preoperative trajectory planning and an intraoperative workflow incorporating navigation and mr thermography. 2019-10-07 2023-08-13 Not clear