All Relations between cup and Thalamus

Publication Sentence Publish Date Extraction Date Species
Shivan S Jassim, Tejasvi Bhatia, Jack R D McMahon, Jim W Pierrepont, Stephen J McMaho. Reliability of the transverse acetabular ligament as a landmark for functional cup anteversion in total hip arthroplasty. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2024-04-04. PMID:38572714. the transverse acetabular ligament (tal) can be a useful and reproducible landmark in the orientation of the acetabular cup in total hip arthroplasty (tha). 2024-04-04 2024-04-06 Not clear
Yohei Naito, Masahiro Hasegawa, Shine Tone, Hiroki Wakabayashi, Akihiro Sud. Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology. Archives of orthopaedic and trauma surgery. 2024-03-30. PMID:38554208. this study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (tha) in the lateral decubitus position using a new computed tomography (ct)-based navigation system with augmented reality (ar) technology. 2024-03-30 2024-04-02 Not clear
Julien Erard, Maria-Roxana Viamont-Guerra, ReSurg, Nicolas Boni. Satisfactory mid-term clinical outcomes of endoscopic tenotomy for iliopsoas tendinopathy following total hip arthroplasty. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2024-03-22. PMID:38515260. to report 5-year outcomes of endoscopic iliopsoas tenotomy in patients with iliopsoas tendinopathy following total hip arthroplasty (tha) and determine whether clinical scores are associated with cup position. 2024-03-22 2024-03-24 Not clear
Adam J Taylor, Christopher L Peter. In Adults Having Primary THA, an AR-Based Navigation System Improved Cup Positioning, But Not Clinical Outcomes, Versus a Conventional Technique. The Journal of bone and joint surgery. American volume. 2024-03-21. PMID:38512970. in adults having primary tha, an ar-based navigation system improved cup positioning, but not clinical outcomes, versus a conventional technique. 2024-03-21 2024-03-24 Not clear
Hongbin Xie, Jiafeng Yi, Yijian Huang, Renwen Guo, Yubo Liu, Xiangpeng Kong, Wei Cha. Application and evaluation of artificial intelligence 3D preoperative planning software in developmental dysplasia of the hip. Journal of orthopaedic surgery and research. vol 19. issue 1. 2024-03-08. PMID:38459538. the aim of this study was to compare the accuracy of an artificial intelligence-assisted three-dimensional (3d) planning system (aihip) with two-dimensional templates in predicting acetabular cup size in tha for ddh. 2024-03-08 2024-03-11 Not clear
Yasuhiro Homma, Xu Zhuang, Taiji Watari, Koju Hayashi, Tomonori Baba, Atul Kamath, Muneaki Ishijim. Differences in acoustic parameters of hammering sounds between successful and unsuccessful initial cementless cup press-fit fixation in total hip arthroplasty. Bone & joint open. vol 5. issue 3. 2024-02-29. PMID:38423101. it is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (tha) in order to better understand the change of the sound during impaction. 2024-02-29 2024-03-03 Not clear
Yasuhiro Homma, Xu Zhuang, Taiji Watari, Koju Hayashi, Tomonori Baba, Atul Kamath, Muneaki Ishijim. Differences in acoustic parameters of hammering sounds between successful and unsuccessful initial cementless cup press-fit fixation in total hip arthroplasty. Bone & joint open. vol 5. issue 3. 2024-02-29. PMID:38423101. we designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in tha. 2024-02-29 2024-03-03 Not clear
Max Hardwick-Morris, Joshua Twiggs, Brad Miles, Rami M A Al-Dirini, Mark Taylor, Jitendra Balakumar, William L Walte. Comparison of iliopsoas tendonitis after hip resurfacing arthroplasty and total hip arthroplasty: A case-controlled investigation using a validated simulation. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2024-02-17. PMID:38366978. iliopsoas tendonitis, typically caused by impingement with the acetabular cup, occurs in up to 18% of patients after total hip arthroplasty (tha) and up to 30% of patients after hip resurfacing arthroplasty (hra). 2024-02-17 2024-02-20 Not clear
Shuai Zhang, Mingyang Ma, Xiangpeng Kong, Yonggang Zhou, Jiying Chen, Wei Cha. Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip. International orthopaedics. 2024-02-15. PMID:38358516. the purpose of this study was to comprehensively evaluate the clinical outcomes of robot-assisted tha in patients with ddh through a large cohort study, including the precision of acetabular cup positioning, indicators of inflammatory response, indicators of muscle damage, and complications. 2024-02-15 2024-02-17 Not clear
Tiziano Villa, Angelo Alberto Tenconi, Marta Colombo, Lorenzo Banc. Hip arthrodesis conversion to dual mobility total hip arthroplasty in a young adult using a custom-made highly-porous titanium monobloc cup: A case report. International journal of surgery case reports. vol 116. 2024-02-13. PMID:38350380. herein, a case of arthrodesis takedown to a dual mobility tha with a custom-made 3d-printed cup. 2024-02-13 2024-02-16 Not clear
Çetin Işık, Mesut Tahta, Fahri Emr. Placement of Standard Sized Acetabular Cup Between True and False Acetabulum in Patients with Crowe III/IV Dysplasia: A Safe Option in THA Without Femoral Osteotomy. Indian journal of orthopaedics. vol 58. issue 2. 2024-02-05. PMID:38312905. placement of standard sized acetabular cup between true and false acetabulum in patients with crowe iii/iv dysplasia: a safe option in tha without femoral osteotomy. 2024-02-05 2024-02-07 Not clear
Çetin Işık, Mesut Tahta, Fahri Emr. Placement of Standard Sized Acetabular Cup Between True and False Acetabulum in Patients with Crowe III/IV Dysplasia: A Safe Option in THA Without Femoral Osteotomy. Indian journal of orthopaedics. vol 58. issue 2. 2024-02-05. PMID:38312905. in this study by placing the acetabular cup between the true and false acetabulum, we aimed to share our experience about criteria of patient selection, surgical technique, and mid-term results of tha (total hip arthroplasty) in which the risk of dislocation was minimized using a standard-sized acetabular cup. 2024-02-05 2024-02-07 Not clear
Jung-Wee Park, Jae-Hyun Park, Hong-Seok Kim, Young-Kyun Lee, Kye-Young Han, Yong-Chan Ha, Kyung-Hoi Ko. Optimization of Acetabular Cup Abduction by Adjusting Pelvic Pitch. Clinics in orthopedic surgery. vol 16. issue 1. 2024-02-02. PMID:38304220. the purposes of this study were to determine the accuracy of our cup positioning method and to evaluate the dislocation rate after total hip arthroplasty (tha). 2024-02-02 2024-02-04 Not clear
Zhuokai Li, Yang Yang, Shengyang Guo, Ju Liu, Xiaoxiao Zhou, Houlin J. Insufficient stem antetorsion and lower cup abduction is a combined risk factor for posterior hip dislocation in patients undergoing THA for femoral neck fractures: a retrospective analysis. BMC musculoskeletal disorders. vol 25. issue 1. 2024-01-30. PMID:38291445. insufficient stem antetorsion and lower cup abduction is a combined risk factor for posterior hip dislocation in patients undergoing tha for femoral neck fractures: a retrospective analysis. 2024-01-30 2024-02-02 Not clear
Albin Christensson, Hassan M Nemati, Gunnar Flivi. Comparison between model-based RSA and an AI-based CT-RSA: an accuracy study of 30 patients. Acta orthopaedica. vol 95. 2024-01-29. PMID:38284788. we aimed to evaluate agreement between a new artificial intelligence (ai)-based ct-rsa and model-based rsa (mbrsa) in measuring migration of cup and stem in total hip arthroplasty (tha). 2024-01-29 2024-01-31 Not clear
Ning Yi, Hang Yuan, Nanwei Xu, Ruiping Liu, Yuji Wang, Chao Zhuan. Digital protractor as an intraoperative guide to cup anteversion in total hip arthroplasty. BMC surgery. vol 24. issue 1. 2024-01-18. PMID:38238716. to explore if digital protractor could guide the anteversion of acetabular cup during primary tha and make it consistent with preoperative. 2024-01-18 2024-01-21 Not clear
Christian Stadler, Sandra Feldler, Stella Stevoska, Clemens Schopper, Tobias Gotterbarm, Matthias Luge. Gender differences in cementless short stem total hip arthroplasty: significantly higher femoral lengthening in female patients. Scientific reports. vol 14. issue 1. 2024-01-11. PMID:38212361. female patients are at higher risk of femoral lengthening in tha with a cementless short stem potentially caused by a further proximally conducted femoral neck osteotomy and show significantly higher cup anteversion angles. 2024-01-11 2024-01-14 Not clear
Makoto Hamawaki, Hidetoshi Hamada, Keisuke Uemura, Kazuma Takashima, Hirokazu Mae, Nobuo Nakamura, Nobuhiko Sugan. Rigid fixation of pelvic tracker essential for accurate cup placement in CT-based navigation total hip arthroplasty. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2024-01-09. PMID:38195733. here, we asked: (1) how pelvic tracker displacement influences the ctn accuracy of cup orientation in total hip arthroplasty (tha)? 2024-01-09 2024-01-13 human
Makoto Hamawaki, Hidetoshi Hamada, Keisuke Uemura, Kazuma Takashima, Hirokazu Mae, Nobuo Nakamura, Nobuhiko Sugan. Rigid fixation of pelvic tracker essential for accurate cup placement in CT-based navigation total hip arthroplasty. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2024-01-09. PMID:38195733. regarding cup orientation in 446 tha procedures using ctn, we evaluated clinical error defined as the difference between postoperative measurement and preoperative planning and measurement error defined as the difference between postoperative and intraoperative measurements. 2024-01-09 2024-01-13 human
Tong Li, Yifei Li, Weiguo Wan. Association between cup orientation and low back pain after total hip arthroplasty in patients with osteonecrosis of the femoral head. BMC musculoskeletal disorders. vol 25. issue 1. 2024-01-03. PMID:38167127. the purpose of this study was to explore the correlations between cup orientation of tha and postoperative lbp in patients with osteonecrosis of the femoral head (onfh). 2024-01-03 2024-01-06 Not clear