Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Akira Fujita, Koji Goto, Akihiko Ueda, Yutaka Kuroda, Toshiyuki Kawai, Yaichiro Okuzu, Yasushi Okuno, Shuichi Matsud. Measurement of the Acetabular Cup Orientation after Total Hip Arthroplasty Based on Three-Dimensional Reconstruction from a Single X-ray Image Using Generative Adversarial Networks. The Journal of arthroplasty. 2024-06-29. PMID:38944061. |
the purpose of this study was to reconstruct three-dimensional (3d) computed tomography (ct) images from single anteroposterior (ap) postoperative total hip arthroplasty (tha) x-ray images using a deep learning algorithm known as generative adversarial networks (gans) and to validate the accuracy of cup angle measurement on gan-generated ct. |
2024-06-29 |
2024-07-02 |
Not clear |
Saad Tarabichi, Colin M Baker, Juan D Lizcano, Elizabeth A Abe, Graham S Goh, P Maxwell Courtne. Porous Metal Augments Have Comparable Outcomes to Other Constructs for Severe Acetabular Bone Loss at Mid-Term Follow-up. The Journal of arthroplasty. 2024-06-22. PMID:38844248. |
the purpose of this study was to compare the outcomes of revision total hip arthroplasty (tha) for severe bone loss using porous metal augments to cup cage and triflange prostheses. |
2024-06-22 |
2024-06-25 |
Not clear |
Junya Shimizu, Satoshi Nagoya, Ima Kosukegawa, Arata Kanaizumi, Naoya Nakahashi, Atsushi Teramot. The Accuracy of Cup Placement in Total Hip Arthroplasty (THA) Using an Augmented Reality-Based Navigation System. Cureus. vol 16. issue 4. 2024-06-03. PMID:38826595. |
the accuracy of cup placement in total hip arthroplasty (tha) using an augmented reality-based navigation system. |
2024-06-03 |
2024-06-05 |
Not clear |
Run Tian, Xu Gao, Ning Kong, Xinghua Li, Yiyang Li, Jian Wang, Yongping Cao, Zhanjun Shi, Kunzheng Wang, Pei Yan. A new seven-axis robotic-assisted total hip arthroplasty system improves component positioning: a prospective, randomized, multicenter study. Scientific reports. vol 14. issue 1. 2024-06-02. PMID:38825602. |
the seven-axis robotic-assisted tha system is safe and effective, and leads to better acetabulum cup positioning compared to conventional tha. |
2024-06-02 |
2024-06-05 |
Not clear |
Weihua Li, Yan Huang, Zehui Zou, Xuqiang Liu, Xiaofeng L. Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-05-30. PMID:38816424. |
cup anteversion in direct anterior approach (daa) total hip arthroplasty (tha) is often excessive. |
2024-05-30 |
2024-06-02 |
Not clear |
Weihua Li, Yan Huang, Zehui Zou, Xuqiang Liu, Xiaofeng L. Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-05-30. PMID:38816424. |
sixty-two consecutive hips underwent primary tha utilizing daa alongside if for cup placement. |
2024-05-30 |
2024-06-02 |
Not clear |
Xiaomin Li, Yang Qu, Liao Wang, Songtao A. The accuracy of cup anteversion measurement on postoperative pelvic radiographs: A comparative retrospective cohort study between DDH and non-DDH patients. Heliyon. vol 10. issue 10. 2024-05-29. PMID:38803989. |
postoperative pelvic radiographs remain a vital tool for assessing cup orientation after total hip arthroplasty (tha), with the accuracy influenced by various factors. |
2024-05-29 |
2024-06-03 |
Not clear |
Bartosz Maciąg, Dawid Jegierski, Bartłomiej Wilk, Martyna Budzińska, Grzegorz Maciąg, Anna Kupczak, Krystian Żarnovsky, Marcin Łapiński, Tomasz Kordyaczny, Artur Stolarczy. Impact of acetabular roof's angle on precision of cup center of rotation reproduction and placement in total hip arthroplasty. Reumatologia. vol 62. issue 2. 2024-05-27. PMID:38799773. |
the aim of this study was to assess whether the superior border of the native acetabulum morphology has an impact on cup positioning and cor restoration in patients undergoing tha as treatment of primary oa of the hip. |
2024-05-27 |
2024-05-31 |
Not clear |
Changjun Xiong, Yunzhou Zuo, Xiaokang Yan, Guan Wang, Hao Fu, Xueming Jian. [Application of modified acetabular anteversion and inclination angles test system in patients undergoing total hip arthroplasty after lumbar fusion]. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. vol 38. issue 5. 2024-05-16. PMID:38752244. |
to investigate the accuracy and effectiveness of acetabular cup placement in total hip arthroplasty (tha) after lumbar fusion applying of modified acetabular anteversion and inclination angles test system. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
the accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (tha) in the lateral decubitus position remains challenging. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in tha. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
this study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-apn) system and a novel accelerometer-based portable navigation (n-apn) system during tha in the lateral decubitus position. |
2024-05-16 |
2024-05-27 |
Not clear |
Geert Meermans, David Fawley, Luigi Zagra, René H M Ten Broeke, Kory Johnson, Thierry Bernard, Henry Clayton Thomaso. Accuracy of cup placement compared with preoperative surgeon targets in primary total hip arthroplasty using standard instrumentation and techniques: a global, multicenter study. Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology. vol 25. issue 1. 2024-05-10. PMID:38727945. |
acetabular cup positioning in total hip arthroplasty (tha) is closely related to outcomes. |
2024-05-10 |
2024-05-27 |
Not clear |
Sanjay Agarwala, Tej Shah, Mayank Vijayvargiy. Cage Augmentation of the Retained Acetabular Shell with a Dual Mobility Cup using the Double Socket Technique. Journal of orthopaedic case reports. vol 14. issue 4. 2024-04-29. PMID:38681926. |
in revision scenarios with previous well-fixed acetabulum shells, the cementation of polyethylene liners or the cementation of dual mobility (dm) into a well-fixed acetabulum shell (double socket technique) has been documented before.here, we report a case of re-revision tha, where we have used the double socket technique of retaining the previous well-fixed acetabular shell with the cementation of the dm cup along with an anti-protrusio cage inside the socket. |
2024-04-29 |
2024-05-01 |
Not clear |
Shinya Hayashi, Yuichi Kuroda, Naoki Nakano, Tomoyuki Matsumoto, Tomoyuki Kamenaga, Masanori Tsubosaka, Ryosuke Kurod. Accuracy of portable navigation during THA in patients with severe developmental dysplasia of hip. Archives of orthopaedic and trauma surgery. 2024-04-25. PMID:38661997. |
correct cup placement in total hip arthroplasty (tha) for patients with developmental dysplasia of the hip (ddh) is considerably difficult. |
2024-04-25 |
2024-04-28 |
Not clear |
Shinya Hayashi, Yuichi Kuroda, Naoki Nakano, Tomoyuki Matsumoto, Tomoyuki Kamenaga, Masanori Tsubosaka, Ryosuke Kurod. Accuracy of portable navigation during THA in patients with severe developmental dysplasia of hip. Archives of orthopaedic and trauma surgery. 2024-04-25. PMID:38661997. |
this study aimed to analyze the orientation accuracy of cup insertion during tha using a portable navigation system in patients with ddh. |
2024-04-25 |
2024-04-28 |
Not clear |
Dong Li, Yong Zhang, Zuqing Chen, Wenju Chang, Hai Din. [Estimation of acetabular cup prosthesis coverage rate in total hip arthroplasty based on X-ray films]. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. vol 38. issue 4. 2024-04-17. PMID:38632067. |
to explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (tha) based on x-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. |
2024-04-17 |
2024-04-20 |
Not clear |
Guo Chen, Chen Yi Wang, Zou Ma, Hong Lin Yi, Na Meng Bi, Wei Jiang Zhu, Jie Han, Sha Li Lu, Shang Shang Zhang, Hai Shen, Wu Hui Zhang, Peng Zhang, Yan S. A prospective and consecutive study assessing short-term clinical and radiographic outcomes of Chinese domestically manufactured 3D printing trabecular titanium acetabular cup for primary total hip arthroplasty: evaluation of 236 cases. Frontiers in surgery. vol 11. 2024-04-11. PMID:38601877. |
we prospectively evaluate the short-term clinical and radiographic outcomes of the only chinese domestically produced trabecular titanium acetabular cup(3d act™ cup) in primary total hip arthroplasty (tha), aiming to provide evidence-based support for its clinical application. |
2024-04-11 |
2024-04-13 |
Not clear |
Thomas D Alter, Matthew L Hadley, Cory G Couch, Kristin M Fruth, Nicholas A Bedard, Kevin I Perry, Rafael J Sierra, David G Lewalle. Highly Porous Acetabular Cup and Augment Constructs in Complex Revision Total Hip Arthroplasty: What Predicts 10 Year Implant Survivorship? The Journal of arthroplasty. 2024-04-10. PMID:38599525. |
porous tantalum acetabular cup and augment constructs have demonstrated favorable outcomes up to five years post-surgery despite severe bone loss during revision total hip arthroplasty (tha). |
2024-04-10 |
2024-04-13 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
this study compared the accuracy of cup insertion during tha using ar-ct-based and portable ar-based navigation systems. |
2024-04-09 |
2024-04-12 |
Not clear |