All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
Kanabu Nawa, Akihiro Haga, Akihiro Nomoto, Raniel A Sarmiento, Kenshiro Shiraishi, Hideomi Yamashita, Keiichi Nakagaw. Evaluation of a commercial automatic treatment planning system for prostate cancers. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28549556. recent developments in radiation oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) planning. 2018-05-09 2023-08-13 Not clear
Ashley Coffey, Lisa Renucci, Ashley Hunzeker, Nishele Lenard. Whole breast nodal irradiation using supine VMAT and prone 3D planning: A case study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28579017. whole breast nodal irradiation using supine vmat and prone 3d planning: a case study. 2018-05-09 2023-08-13 Not clear
Ashley Coffey, Lisa Renucci, Ashley Hunzeker, Nishele Lenard. Whole breast nodal irradiation using supine VMAT and prone 3D planning: A case study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 3. 2018-05-09. PMID:28579017. in this study, 3 patients who were simulated in the prone and supine positions were planned using supine vmat and prone 3dcrt techniques to compare planning target volume (ptv) coverage as well as dose to organs at risk (ors), including the heart and ipsilateral lung. 2018-05-09 2023-08-13 Not clear
Lijun Ma, Lei Wang, Chia-Lin Tseng, Arjun Sahga. Emerging technologies in stereotactic body radiotherapy. Chinese clinical oncology. vol 6. issue Suppl 2. 2018-04-20. PMID:28917250. as a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (vmat), sbrt has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. 2018-04-20 2023-08-13 Not clear
Jang-Chun Lin, Jo-Ting Tsai, Li-Jhen Chen, Ming-Hsien Li, Wei-Hsiu Li. Compared planning dosimetry of TOMO, VMAT and IMRT in rectal cancer with different simulated positions. Oncotarget. vol 8. issue 26. 2018-04-06. PMID:28159930. compared planning dosimetry of tomo, vmat and imrt in rectal cancer with different simulated positions. 2018-04-06 2023-08-13 Not clear
Wei Liu, Samir H Patel, Daniel P Harrington, Yanle Hu, Xiaoning Ding, Jiajian Shen, Michele Y Halyard, Steven E Schild, William W Wong, Gary E Ezzell, Martin Bue. Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer. Journal of applied clinical medical physics. vol 18. issue 4. 2018-04-02. PMID:28503916. this work is to show which is more relevant to cause local failures (lfs) due to patient setup uncertainty between the planning target volume (ptv) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (h&n) cancer treated with volumetric-modulated arc therapy (vmat). 2018-04-02 2023-08-13 human
Nigel D Middlebrook, Bess Sutherland, Tanya Kair. Optimization of the dosimetric leaf gap for use in planning VMAT treatments of spine SABR cases. Journal of applied clinical medical physics. vol 18. issue 4. 2018-04-02. PMID:28574219. optimization of the dosimetric leaf gap for use in planning vmat treatments of spine sabr cases. 2018-04-02 2023-08-13 Not clear
Hideharu Miura, Shuichi Ozawa, Yasushi Nagat. Efficacy of robust optimization plan with partial-arc VMAT for photon volumetric-modulated arc therapy: A phantom study. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28691343. this study investigated position dependence in planning target volume (ptv)-based and robust optimization plans using full-arc and partial-arc volumetric modulated arc therapy (vmat). 2018-04-02 2023-08-13 Not clear
Marius Treutwein, Matthias Hipp, Oliver Koelbl, Barbara Doble. Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators. Journal of applied clinical medical physics. vol 18. issue 5. 2018-04-02. PMID:28857432. for ten patients, four different plans were calculated with oncentra planning system of elekta, using synergy machines: imrt and vmat, with and without flattening filter. 2018-04-02 2023-08-13 Not clear
Jinling Yi, Ce Han, Xiaomin Zheng, Yongqiang Zhou, Zhenxiang Deng, Congying Xie, Xiance Jin, Fu Ji. Individual volume-based 3D gamma indices for pretreatment VMAT QA. Journal of applied clinical medical physics. vol 18. issue 3. 2018-03-30. PMID:28318101. percentage dosimetric errors (%de) of dose-volume histogram metrics (includes target volumes and organ at risks) between the treatment planning system and qa-reconstructed dose distribution, %gps for individual volume and global gamma indices, as well their correlations and sensitivities were investigated for one- and two-arc vmat plans. 2018-03-30 2023-08-13 Not clear
Stephen J Gardner, Siming Lu, Chang Liu, Ning Wen, Indrin J Chett. Tuning of AcurosXB source size setting for small intracranial targets. Journal of applied clinical medical physics. vol 18. issue 3. 2018-03-30. PMID:28470819. the vendor-recommended 1.00 mm source size was suitable for truebeam planning (both vmat and dca planning) and edge dca planning. 2018-03-30 2023-08-13 Not clear
Stephen J Gardner, Siming Lu, Chang Liu, Ning Wen, Indrin J Chett. Tuning of AcurosXB source size setting for small intracranial targets. Journal of applied clinical medical physics. vol 18. issue 3. 2018-03-30. PMID:28470819. however, for edge vmat planning, the 0.50 mm source size yielded the highest passing rates. 2018-03-30 2023-08-13 Not clear
Te-Yu Chyou, Friedlieb Loren. Couch modelling for volumetric modulated arc therapy (VMAT). Australasian physical & engineering sciences in medicine. vol 40. issue 2. 2018-03-26. PMID:28597229. for this purpose two models of the varian exact couch (varian medical systems, palo alto, ca, usa) for use in the planning of volumetric modulated arc therapy (vmat) were created in monaco 5.1 (elekta, stockholm, sweden). 2018-03-26 2023-08-13 Not clear
Soo-Min Chae, Ki Woong Lee, Seok Hyun So. Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion. Oncotarget. vol 7. issue 47. 2018-03-20. PMID:27806336. dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the imrt and vmat planning for pituitary adenoma lesion. 2018-03-20 2023-08-13 Not clear
Richard Powis, Andrew Bird, Matthew Brennan, Susan Hinks, Hannah Newman, Katie Reed, John Sage, Gareth Webste. Clinical implementation of a knowledge based planning tool for prostate VMAT. Radiation oncology (London, England). vol 12. issue 1. 2018-03-14. PMID:28482845. clinical implementation of a knowledge based planning tool for prostate vmat. 2018-03-14 2023-08-13 Not clear
Richard Powis, Andrew Bird, Matthew Brennan, Susan Hinks, Hannah Newman, Katie Reed, John Sage, Gareth Webste. Clinical implementation of a knowledge based planning tool for prostate VMAT. Radiation oncology (London, England). vol 12. issue 1. 2018-03-14. PMID:28482845. a knowledge based planning tool has been developed and implemented for prostate vmat radiotherapy plans providing a target average rectum dose value based on previously achievable values for similar rectum/ptv overlap. 2018-03-14 2023-08-13 Not clear
Eva Sau Fan Liu, Vincent Wing Cheung Wu, Benjamin Harris, Margot Lehman, David Pryor, Lawrence Wing Chi Cha. Vector-model-supported approach in prostate plan optimization. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 2. 2018-03-12. PMID:28318936. for s&s imrt, 1-arc vmat, and 2-arc vmat prostate plans, there was a significant reduction in the planning time and iteration with vector-model-supported optimization by almost 50%. 2018-03-12 2023-08-13 Not clear
Alan M Kalet, Hannah L Richardson, Darrin A Nikolaisen, Ning Cao, Myra A Lavilla, Claire Dempsey, Juergen Meyer, Wui-Jin Koh, Kenneth J Russel. Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 42. issue 2. 2018-03-12. PMID:28476456. dosimetric comparison of single-beam multi-arc and 2-beam multi-arc vmat optimization in the monaco treatment planning system. 2018-03-12 2023-08-13 Not clear
Juanqi Wang, Zhaozhi Yang, Weigang Hu, Zhi Chen, Xiaoli Yu, Xiaomao Gu. Intensity modulated radiotherapy with fixed collimator jaws for locoregional left-sided breast cancer irradiation. Oncotarget. vol 8. issue 20. 2018-03-05. PMID:28402279. for each patient, treatment plans using different planning techniques, i.e., volumetric modulated arc therapy (vmat), tangential imrt (tangential-imrt), and imrt with fjt (fjt-imrt) were developed for dosimetric comparisons. 2018-03-05 2023-08-13 Not clear
Murugesan Kathirvel, Vellaiyan Subramani, V S Subramanian, Shanmugam Thirumalai Swamy, Gandhi Arun, Subramanian Kal. Dosimetric comparison of head and neck cancer patients planned with multivendor volumetric modulated arc therapy technology. Journal of cancer research and therapeutics. vol 13. issue 1. 2018-02-20. PMID:28508845. vmat treatment planning can be done using biological (treatment planning system [tpsb]: monaco) or physical (tpsp: eclipse)-based cost function optimization techniques. 2018-02-20 2023-08-13 Not clear