All Relations between planning and vmat

Publication Sentence Publish Date Extraction Date Species
A Haga, K Nakagawa, H Yamashita, W Takahashi, A Sakumi, Y Masutani, S Kida, N Saotome, S Itoh, T Shiraki, K Ohtom. SU-E-J-203: Determination of PTV Margin for Lung Tumor Using In-Treatment 4D CBCT. Medical physics. vol 39. issue 6Part9. 2019-11-20. PMID:28519043. to determine a planning target volume (ptv) margin for lung cancer patients using a four-dimensional cone-beam ct (4d cbct) acquired during volumetric modulated arc therapy (vmat) treatment. 2019-11-20 2023-08-13 Not clear
Vasanthan Sakthivel, Ganesh Kadirampatti Mani, Sunil Mani, Raghavendiran Boopath. Radiation-Induced Second Cancer Risk from External Beam Photon Radiotherapy for Head and Neck Cancer: Impact on in-Field and Out-of-Field Organs Asian Pacific journal of cancer prevention : APJCP. vol 18. issue 7. 2019-11-20. PMID:28749618. in order toexamine the impact of choices of various planning techniques, numbers of beams and beam energy used in treatmentplans - 7 and 9 field intensity modulated radiotherapy (imrt) plans using 6mv and 10 mv beam energies and a 6mvvolumetric modulated arc therapy (vmat) plans were planned. 2019-11-20 2023-08-13 Not clear
Ashokkumar Sangaiah, K M Ganesh, K Ramalingam, K Karthikeyan, N Jagadheeskuma. Dosimetric Validation of Volumetric Modulated Arc Therapy (VMAT) Using AAPM TG-119 Benchmark Plans in an Upgraded CLINAC 2100CD for Flattening Filter Free (FFF) Photon Beams Asian Pacific journal of cancer prevention : APJCP. vol 18. issue 11. 2019-11-20. PMID:29172266. for theseclinical cases we generated four treatment plans using imrt ff, imrt fff, vmat ff and vmat fff on a varianclinac 2100cd machine equipped with a millennium 120 mlc in eclipse treatment planning system. 2019-11-20 2023-08-13 Not clear
Jong Min Park, So-Yeon Park, Chang Heon Choi, Minsoo Chun, Jin Ho Kim, Jung-In Ki. Treatment plan comparison between Tri-Co-60 magnetic-resonance image-guided radiation therapy and volumetric modulated arc therapy for prostate cancer. Oncotarget. vol 8. issue 53. 2019-11-20. PMID:29207634. vmat had a primary planning target volume (primary ctv + 1 cm or 2 cm margins) and a boost ptv (boost ctv + 0.7 cm margins), respectively. 2019-11-20 2023-08-13 Not clear
Atallah Baydoun, Neha Vapiwala, Lee E Ponsky, Musaddiq Awan, Ali Kassaee, David Sutton, Tarun K Podder, Yuxia Zhang, Donald Dobbins, Raymond F Muzic, Bryan Traughber, Mitchell Machtay, Rodney Elli. Comparative analysis for renal stereotactic body radiotherapy using Cyberknife, VMAT and proton therapy based treatment planning. Journal of applied clinical medical physics. 2019-11-20. PMID:29542260. comparative analysis for renal stereotactic body radiotherapy using cyberknife, vmat and proton therapy based treatment planning. 2019-11-20 2023-08-13 Not clear
Pengfei Jia, Jun Xu, Xiaoxi Zhou, Jian Chen, Lemin Tan. [Comparison of planning quality and delivery efficiency between volumetric modulated arc therapy and dynamic intensity modulated radiation therapy for nasopharyngeal carcinoma with more than 4 prescribed dose levels]. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. vol 34. issue 6. 2019-11-20. PMID:29761987. the aim of this study is to compare the planning quality and delivery efficiency between dynamic intensity modulated radiation therapy (d-imrt) and dual arc volumetric modulated arc therapy (vmat) systematically for nasopharyngeal carcinoma (npc) patients with multi-prescribed dose levels, and to analyze the correlations between target volumes and plan qualities. 2019-11-20 2023-08-13 Not clear
Pengfei Jia, Jun Xu, Xiaoxi Zhou, Jian Chen, Lemin Tan. [Comparison of planning quality and delivery efficiency between volumetric modulated arc therapy and dynamic intensity modulated radiation therapy for nasopharyngeal carcinoma with more than 4 prescribed dose levels]. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. vol 34. issue 6. 2019-11-20. PMID:29761987. the conform indexes (cis) of planning target volumes (ptvs) in vmat plans were obviously high than those in d-imrt plans ( 2019-11-20 2023-08-13 Not clear
Craig A Elith, Fred Cao, Shane E Dempsey, Naomi Findlay, Helen Warren-Forwar. A Retrospective Planning Analysis Comparing Volumetric-Modulated Arc Therapy (VMAT) to Intensity-Modulated Radiation Therapy (IMRT) for Radiotherapy Treatment of Prostate Cancer. Journal of medical imaging and radiation sciences. vol 44. issue 2. 2019-11-20. PMID:31051937. a retrospective planning analysis comparing volumetric-modulated arc therapy (vmat) to intensity-modulated radiation therapy (imrt) for radiotherapy treatment of prostate cancer. 2019-11-20 2023-08-13 Not clear
Craig A Elith, Fred Cao, Shane E Dempsey, Naomi Findlay, Helen Warren-Forwar. A Retrospective Planning Analysis Comparing Volumetric-Modulated Arc Therapy (VMAT) to Intensity-Modulated Radiation Therapy (IMRT) for Radiotherapy Treatment of Prostate Cancer. Journal of medical imaging and radiation sciences. vol 44. issue 2. 2019-11-20. PMID:31051937. particular focus was placed on the impact imrt and vmat have on departmental planning and treatment resources. 2019-11-20 2023-08-13 Not clear
Fiorenza De Rose, Antonella Fogliata, Davide Franceschini, Salvatore Cozzi, Cristina Iftode, Antonella Stravato, Stefano Tomatis, Giovanna Masci, Rosalba Torrisi, Alberto Testori, Corrado Tinterri, Andrea V E Lisa, Luca Maione, Valeriano Vinci, Marco Klinger, Armando Santoro, Marta Scorsett. Postmastectomy radiation therapy using VMAT technique for breast cancer patients with expander reconstruction. Medical oncology (Northwood, London, England). vol 36. issue 6. 2019-11-15. PMID:31028487. we retrospectively evaluate the complication rates of pmrt using vmat technique to immediate tissue expander-based reconstructions and the possible impact of tissue expander volume on radiotherapy planning. 2019-11-15 2023-08-13 Not clear
Hironori Akiyama, Csilla Pesznyák, Dalma Béla, Örs Ferenczi, Tibor Major, Csaba Polgár, Zoltán Takácsi-Nag. Image guided high-dose-rate brachytherapy versus volumetric modulated arc therapy for head and neck cancer: A comparative analysis of dosimetry for target volume and organs at risk. Radiology and oncology. vol 52. issue 4. 2019-09-30. PMID:30422804. background the aim of the study was to present dosimetric comparison of image guided high-dose-rate brachytherapy (igbt) with volumetric modulated arc therapy (vmat) for head and neck cancer regarding conformity of dose distribution to planning target volume (ptv) and doses to organs at risk (oars). 2019-09-30 2023-08-13 Not clear
Crispen Chamunyonga, Julie Burbery, Peter Caldwell, Peta Rutledge, Andrew Fielding, Scott Crow. Utilising the Virtual Environment for Radiotherapy Training System to Support Undergraduate Teaching of IMRT, VMAT, DCAT Treatment Planning, and QA Concepts. Journal of medical imaging and radiation sciences. vol 49. issue 1. 2019-09-30. PMID:30479285. utilising the virtual environment for radiotherapy training system to support undergraduate teaching of imrt, vmat, dcat treatment planning, and qa concepts. 2019-09-30 2023-08-13 Not clear
Biplab Sarkar, Anusheel Munshi, Tharmarnadar Ganesh, Arjunan Manikandan, Satheesh Kumar Anbazhagan, Bidhu Kalyan Mohant. Standardization of volumetric modulated arc therapy-based frameless stereotactic technique using a multidimensional ensemble-aided knowledge-based planning. Medical physics. vol 46. issue 5. 2019-09-12. PMID:30854658. aim of this article is to describe a new knowledge-based planning (kbp) methodology using volumetric modulated arc therapy (vmat) for stereotactic radiosurgery (srs) and radiotherapy (srt) assisted by an ensemble mapping technique for use in a monte carlo planning system. 2019-09-12 2023-08-13 Not clear
Hande Bas Ayata, Cemile Ceylan, Ayhan Kılıç, Metin Güden, Kayıhan Engi. Comparison of Multiple Treatment Planning Techniques for High-Grade Glioma Tumors Near to Critical Organs. Oncology research and treatment. vol 41. issue 9. 2019-09-03. PMID:30086547. the purpose of this study was to compare 6 treatment planning methods (5-beam coplanar intensity-modulated radiotherapy (imrt), 7-beam coplanar imrt, 7-beam noncoplanar imrt, 2 full arc coplanar volumetric modulated arc therapy (vmat), 2 half partial arc coplanar vmat, and 2 half partial arc noncoplanar vmat) for high-grade gliomas with planning target volumes (ptvs) overlapping the optic pathway and/or brainstem. 2019-09-03 2023-08-13 Not clear
Eric Christiansen, Emily Heath, Tong X. Continuous aperture dose calculation and optimization for volumetric modulated arc therapy. Physics in medicine and biology. vol 63. issue 21. 2019-08-22. PMID:30362464. this continuous aperture fluence calculation is integrated in the vmat optimization process using the open-source treatment planning system matrad. 2019-08-22 2023-08-13 Not clear
Christina E Agnew, Denise M Irvine, Conor K McGarr. Correlation of phantom-based and log file patient-specific QA with complexity scores for VMAT. Journal of applied clinical medical physics. vol 15. issue 6. 2019-08-16. PMID:25493524. additionally, insight into mlc and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the mcs could also provide further methodologies to both optimize the vmat planning and qa process.  2019-08-16 2023-08-13 Not clear
Yujin Xu, Weiye Deng, Shuangyan Yang, Pu Li, Yue Kong, Ye Tian, Zhongxing Liao, Ming Che. Dosimetric comparison of the helical tomotherapy, volumetric-modulated arc therapy and fixed-field intensity-modulated radiotherapy for stage IIB-IIIB non-small cell lung cancer. Scientific reports. vol 7. issue 1. 2019-07-17. PMID:29093491. the study aimed to compare the dosimetric parameters to target dose coverage and the critical structures in the treatment planning of helical tomotherapy (tomo), volumetric-modulated arc therapy (vmat), and fixed-field intensity-modulated radiotherapy (imrt) for nsclc delivering conventionally fractionated radiotherapy. 2019-07-17 2023-08-13 Not clear
Shingo Ohira, Riho Komiyama, Tsukasa Karino, Hayate Washio, Yoshihiro Ueda, Masayoshi Miyazaki, Masahiko Koizumi, Teruki Teshim. Volumetric modulated arc therapy planning based on virtual monochromatic images: Effect of inaccurate CT numbers on dose distributions. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 60. 2019-06-20. PMID:31000091. we assessed the dosimetric error due to inaccurate hu estimation in volumetric modulated arc therapy (vmat) planning. 2019-06-20 2023-08-13 Not clear
Anabela G Dias, Diana F S Pinto, Maria F Borges, Maria H Pereira, João A M Santos, Luís T Cunha, Joana Lencar. Optimization of skin dose using in-vivo MOSFET dose measurements in bolus/non-bolus fraction ratio: A VMAT and a 3DCRT study. Journal of applied clinical medical physics. vol 20. issue 2. 2019-06-10. PMID:30628154. in-phantom and in-vivo three dimensional conformal radiation therapy (3dcrt) and volumetric modulated arc therapy (vmat) skin doses, measured with and without bolus in a female anthropomorphic phantom rando and in patients, were compared against treatment planning system calculated values. 2019-06-10 2023-08-13 Not clear
Christoph Speier, Giampaolo Pileggi, David Izquierdo-Garcia, Ciprian Catana, Gregory C Sharp, Maria Francesca Spadea, Christoph Bert, Joao Sec. Advanced Multimodal Methods for Cranial Pseudo-CT Generation Validated by IMRT and VMAT Radiation Therapy Plans. International journal of radiation oncology, biology, physics. vol 102. issue 4. 2019-05-31. PMID:29966724. we present 2 novel methods that employ key techniques to enhance pseudo-cts and investigate the effect on image quality and applicability for imrt and vmat planning. 2019-05-31 2023-08-13 Not clear