All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Sou-Tung Chiu-Tsao, Melvin A Astrahan, Paul T Finger, David S Followill, Ali S Meigooni, Christopher S Melhus, Firas Mourtada, Mary E Napolitano, Ravinder Nath, Mark J Rivard, D W O Rogers, Rowan M Thomso. Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS. Medical physics. vol 39. issue 10. 2012-12-05. PMID:23039655. a literature review identified modern assessments of dose calculations for collaborative ocular melanoma study (coms) design plaques, including mc analyses and an intercomparison of treatment planning systems (tps) detailing differences between homogeneous and heterogeneous plaque calculations using the american association of physicists in medicine (aapm) tg-43u1 brachytherapy dosimetry formalism and mc techniques. 2012-12-05 2023-08-12 Not clear
Sou-Tung Chiu-Tsao, Melvin A Astrahan, Paul T Finger, David S Followill, Ali S Meigooni, Christopher S Melhus, Firas Mourtada, Mary E Napolitano, Ravinder Nath, Mark J Rivard, D W O Rogers, Rowan M Thomso. Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS. Medical physics. vol 39. issue 10. 2012-12-05. PMID:23039655. in the interim, before the availability of commercial mc-based brachytherapy tps, it is recommended that clinical medical physicists use the line-source approximation in homogeneous water medium and the 2d aapm tg-43u1 dosimetry formalism and brachytherapy source dosimetry parameter datasets for treatment planning calculations. 2012-12-05 2023-08-12 Not clear
Per Rugaard Poulsen, Mai Lykkegaard Schmidt, Paul Keall, Esben Schjodt Worm, Walther Fledelius, Lone Hoffman. A method of dose reconstruction for moving targets compatible with dynamic treatments. Medical physics. vol 39. issue 10. 2012-12-05. PMID:23039659. to develop a method that allows a commercial treatment planning system (tps) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (imrt), volumetric arc therapy (vmat), and dynamic multileaf collimator (dmlc) tracking. 2012-12-05 2023-08-12 Not clear
Hidenobu Tachibana, Hiroyuki Kojima, Noritaka Yusa, Satoshi Miyajima, Akihisa Tsuda, Takashi Yamashit. Design and development of a new micro-beam treatment planning system: effectiveness of algorithms of optimization and dose calculations and potential of micro-beam treatment. Radiological physics and technology. vol 5. issue 2. 2012-11-27. PMID:22544809. a new treatment planning system (tps) was designed and developed for a new treatment system, which consisted of a micro-beam-enabled linac with robotics and a real-time tracking system. 2012-11-27 2023-08-12 Not clear
O Pisaturo, M Pachoud, F O Bochud, R Moeckl. Calculation of correction factors for ionization chamber measurements with small fields in low-density media. Physics in medicine and biology. vol 57. issue 14. 2012-11-16. PMID:22722819. thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (tps). 2012-11-16 2023-08-12 Not clear
Zhihui Hu, Jianrong Dai, Liang Li, Yin Cao, Guishan F. Evaluating and modeling of photon beam attenuation by a standard treatment couch. Journal of applied clinical medical physics. vol 12. issue 4. 2012-11-13. PMID:22089012. the purpose of this study was to evaluate beam attenuation by treatment couch and build a treatment couch model in tps to check for beam-couch intersection at the planning stage and deal with beam attenuation by treatment couch in dose calculation. 2012-11-13 2023-08-12 Not clear
C Kurz, A Mairani, K Parod. First experimental-based characterization of oxygen ion beam depth dose distributions at the Heidelberg Ion-Beam Therapy Center. Physics in medicine and biology. vol 57. issue 15. 2012-11-07. PMID:22805295. the clinical treatment planning system (tps) at the heidelberg ion-beam therapy center (hit) is based on a fast performing analytical algorithm for dose calculation, relying, among others, on laterally integrated depth dose distributions (ddds) simulated with the fluka monte carlo (mc) code. 2012-11-07 2023-08-12 Not clear
Mahmoud Allahverdi, Mina Sarkhosh, Mahdi Aghili, Ramin Jaberi, Akbar Adelnia, Ghazale Gerail. Evaluation of treatment planning system of brachytherapy according to dose to the rectum delivered. Radiation protection dosimetry. vol 150. issue 3. 2012-10-25. PMID:22128355. the aim of this study was to assess the actual dose delivered to the rectum and compare it with the treatment planning system (tps) reports. 2012-10-25 2023-08-12 Not clear
L Grevillot, D Bertrand, F Dessy, N Freud, D Sarru. GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans. Physics in medicine and biology. vol 57. issue 13. 2012-10-25. PMID:22684098. in this perspective, we upgraded the gate/geant4 monte carlo platform in order to recalculate the treatment planning system (tps) dose distributions for active scanning systems. 2012-10-25 2023-08-12 human
Basak Iktueren, Hatice Bilge, Songul Karacam, Gulyuz Atkova. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator. Radiation protection dosimetry. vol 150. issue 2. 2012-10-11. PMID:22025738. in this study, the peripheral dose outside the applicator was measured using electron beams produced by an oncor linear accelerator and compared with the data of the treatment planning system (tps). 2012-10-11 2023-08-12 Not clear
B Demir, H Bilge, B Günhan, A Koca, S Karaça. The effect of asymmetric collimation on the dose distribution and verification of treatment planning system for asymmetric fields. Journal of B.U.ON. : official journal of the Balkan Union of Oncology. vol 9. issue 1. 2012-10-02. PMID:17385834. this study reports the feasibility of the symmetric fields for the usage of asymmetric fields, and checks the accuracy of treatment planning system (tps). 2012-10-02 2023-08-12 Not clear
Angelo Piermattei, Luca Grimaldi, Giuseppe D'Onofrio, Savino Cilla, Pietro Viola, Maurizio Craus, Andrea Fidanzio, Luigi Azario, Francesco Deodato, Gabriella Macchia, Alessio Morgant. In-vivo portal dosimetry by an ionization chamber. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 21. issue 4. 2012-10-02. PMID:18348857. this way, it is therefore possible to compare the dose, d(m, tps), obtained by a treatment planning system, with the in-vivo dose d(m) value, both defined at density middle point (identified along the beam central axis, where the thick material, in terms of g cm(-2), above and below, is the same). 2012-10-02 2023-08-12 Not clear
Anuj Kumar, Sunil Dutt Sharma, A K Arya, Surabhi Gupta, Deepak Shrotriy. Effect of low-density heterogeneities in telecobalt therapy and validation of dose calculation algorithm of a treatment planning system. Journal of medical physics. vol 36. issue 4. 2012-10-02. PMID:22228928. a computerized treatment planning system (tps) is generally used for calculating the dose distribution in the patient. 2012-10-02 2023-08-12 human
Mohammad Mohammadi, Eva Beza. Evaluation of relative transmitted dose for a step and shoot head and neck intensity modulated radiation therapy using a scanning liquid ionization chamber electronic portal imaging device. Journal of medical physics. vol 37. issue 1. 2012-10-02. PMID:22363108. the dose distributions were then compared with those calculated in a virtual epid using the pinnacle(3) treatment planning system (tps). 2012-10-02 2023-08-12 Not clear
Yingcui Jia, Chris Beltran, Daniel J Indelicato, Stella Flampouri, Zuofeng Li, Thomas E Merchan. Proton therapy dose distribution comparison between Monte Carlo and a treatment planning system for pediatric patients with ependymoma. Medical physics. vol 39. issue 8. 2012-10-02. PMID:22894399. compare dose distributions for pediatric patients with ependymoma calculated using a monte carlo (mc) system and a clinical treatment planning system (tps). 2012-10-02 2023-08-12 Not clear
Farhad Moradi, Seyed Rabi Mahdavi, Ahmad Mostaar, Mohsen Motamed. Commissioning and initial acceptance tests for a commercial convolution dose calculation algorithm for radiotherapy treatment planning in comparison with Monte Carlo simulation and measurement. Journal of medical physics. vol 37. issue 3. 2012-10-02. PMID:22973081. for this purpose an inhomogeneous phantom (imrt thorax phantom) was used and dose curves obtained by the tps (treatment planning system) were compared with experimental measurements and monte carlo (mcnp code) simulation. 2012-10-02 2023-08-12 Not clear
Sanaz Hariri Tabrizi, Alireza Kamali Asl, Zohreh Azm. Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 28. issue 2. 2012-09-20. PMID:21624844. the tg-43 based dosimetry data can be used not only to validate the dedicated treatment planning software (tps), but also to introduce new complementary software to enhance the system performance in gynecological treatments. 2012-09-20 2023-08-12 Not clear
Sharon Wong, Michael Back, Poh Wee Tan, Khai Mun Lee, Shaun Baggarley, Jaide Jay L. Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients? Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 37. issue 2. 2012-09-11. PMID:21865026. point doses from the cms xio® treatment planning system (tps) were calculated for each relevant tld positions and results correlated. 2012-09-11 2023-08-12 Not clear
Borislava Petrovic, Aleksandra Grzadziel, Laza Rutonjski, Krzysztof Slosare. Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements. Radiology and oncology. vol 44. issue 3. 2012-08-30. PMID:22933916. linear array measurements of enhanced dynamic wedge and treatment planning system (tps) calculation for 15 mv photon beam and comparison with electronic portal imaging device (epid) measurements. 2012-08-30 2023-08-12 Not clear
Borislava Petrovic, Aleksandra Grzadziel, Laza Rutonjski, Krzysztof Slosare. Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements. Radiology and oncology. vol 44. issue 3. 2012-08-30. PMID:22933916. this paper has the aim to compare linear array measurements of edw with the calculations of treatment planning system (tps) and the electronic portal imaging device (epid) for 15 mv photon energy. 2012-08-30 2023-08-12 Not clear