All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Landon S Wootton, Jerimy C Polf, Stephen Peterson, Jeff Wilkinson, Marc A Rozner, Peter A Balter, Sam Bedda. Proton dose perturbations caused by high-voltage leads from implanted cardioverter defibrillators. Journal of applied clinical medical physics. vol 13. issue 4. 2013-07-16. PMID:22766952. we then calculated planned doses using a commercial proton treatment planning system (tps), and compared them with the doses delivered in the phantom, measured using radiographic film. 2013-07-16 2023-08-12 Not clear
Soléakhéna Ken, Laure Vieillevigne, Xavier Franceries, Luc Simon, Caroline Supper, Jean-Albert Lotterie, Thomas Filleron, Vincent Lubrano, Isabelle Berry, Emmanuelle Cassol, Martine Delannes, Pierre Celsis, Elizabeth Moyal Cohen-Jonathan, Anne Lapri. Integration method of 3D MR spectroscopy into treatment planning system for glioblastoma IMRT dose painting with integrated simultaneous boost. Radiation oncology (London, England). vol 8. 2013-07-16. PMID:23280007. to integrate 3d mr spectroscopy imaging (mrsi) in the treatment planning system (tps) for glioblastoma dose painting to guide simultaneous integrated boost (sib) in intensity-modulated radiation therapy (imrt). 2013-07-16 2023-08-12 Not clear
Lixin Zhan, Runqing Jiang, Ernest K Ose. Beam coordinate transformations from DICOM to DOSXYZnrc. Physics in medicine and biology. vol 57. issue 24. 2013-05-21. PMID:23175216. a plan generated by a treatment planning system (tps) is often exported in dicom format. 2013-05-21 2023-08-12 Not clear
Gopishankar Natanasabapathi, Vivekanandhan Subbiah, Shashank Sharad Kale, Goura Kishor Rath, S Senthilkumaran, Sanjay Thulkar, Vellaiyan Subramani, M A Laviraj, Raj Kishor Bisht, A K Mahapatr. MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery. Journal of applied clinical medical physics. vol 13. issue 6. 2013-05-09. PMID:23149780. volumetric dose comparison between treatment planning system (tps) and gel measurement was accomplished using an in-house matlab-based program. 2013-05-09 2023-08-12 Not clear
Shinichiro Mori, Toshiyuki Shirai, Yuka Takei, Takuji Furukawa, Taku Inaniwa, Yuka Matsuzaki, Motoki Kumagai, Takeshi Murakami, Koji Nod. Patient handling system for carbon ion beam scanning therapy. Journal of applied clinical medical physics. vol 13. issue 6. 2013-05-09. PMID:23149784. the new facility incorporates three main systems, a scanning irradiation system (s-ir), treatment planning system (tps), and patient handling system (pth). 2013-05-09 2023-08-12 Not clear
Parham Alaei, Emiliano Spez. Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system. Journal of applied clinical medical physics. vol 13. issue 6. 2013-05-09. PMID:23149789. the beams generated by elekta x-ray volume imaging (xvi) kilovoltage cbct (kv cbct) system for various cassettes and filters have been modeled in the philips pinnacle treatment planning system (tps) and used to compute dose to stack and anthropomorphic phantoms. 2013-05-09 2023-08-12 Not clear
Javier Vijande, Facundo Ballester, Zoubir Ouhib, Domingo Granero, M Carmen Pujades-Claumarchirant, Jose Perez-Calatayu. Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy. Brachytherapy. vol 11. issue 6. 2013-05-06. PMID:22226080. the purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a freiburg flap applicator is in agreement with the one predicted by the treatment planning system (tps) using the tg-43 dose-calculation formalism. 2013-05-06 2023-08-12 Not clear
S A Syam Kumar, Prabakar Sukumar, Padmanaban Sriram, Dhanabalan Rajasekaran, Srinu Aketi, Nagarajan Vivekananda. A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 37. issue 4. 2013-04-29. PMID:22626968. the measured isocenter absolute dose was compared with the treatment planning system (tps) plan. 2013-04-29 2023-08-12 Not clear
E L Marchand, A Sahgal, T J Zhang, B A Millar, M Sharpe, D Moseley, D Letournea. Treatment planning and delivery evaluation of volumetric modulated arc therapy for stereotactic body radiotherapy of spinal tumours: impact of arc discretization in planning system. Technology in cancer research & treatment. vol 11. issue 6. 2013-03-27. PMID:22712602. to assess the impact of arc discretization in the treatment planning system (tps), the vmat-91cp plans were modified by almost doubling the number of cps (vmat-181cp). 2013-03-27 2023-08-12 Not clear
Maria F Chan, Sou-Tung Chiu-Tsao, Jingdong Li, Karen Schupak, Preeti Parhar, Chandra Burma. Confirmation of skin doses resulting from bolus effect of intervening alpha-cradle and carbon fiber couch in radiotherapy. Technology in cancer research & treatment. vol 11. issue 6. 2013-03-27. PMID:22712603. the phantom and ac assembly were ct scanned and the ct-images were transferred to the treatment planning system (tps) for calculations in three scenarios: (a) ignoring ac and cfc, (b) accounting for ac only, (c) accounting for both ac and cfc. 2013-03-27 2023-08-12 Not clear
M Stasi, S Bresciani, A Miranti, A Maggio, V Sapino, P Gabriel. Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram. Medical physics. vol 39. issue 12. 2013-03-07. PMID:23231310. the perturbed dvh is calculated by using a dedicated software, 3dvh (sun nuclear corporation, melbourne, fl), which is able to modify the dose distribution calculated by the treatment planning system (tps) according to the dose discrepancies detected with planar measurements in order to predict the delivered 3d dose distribution in the patient. 2013-03-07 2023-08-12 Not clear
Baozhou Sun, Dharanipathy Rangaraj, Sunita Boddu, Murty Goddu, Deshan Yang, Geethpriya Palaniswaamy, Sridhar Yaddanapudi, Omar Wooten, Sasa Muti. Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA. Journal of applied clinical medical physics. vol 13. issue 5. 2013-01-25. PMID:22955649. sixteen imrt treatment plans (5 head-and-neck, 3 rectum, 3 breast, and 5 prostate plans) created with a commercial treatment planning system (tps) were recalculated on a qa phantom. 2013-01-25 2023-08-12 Not clear
Yoshinobu Shimohigashi, Fujio Araki, Hirofumi Tominaga, Junichi Sakata, Keiichi Kawasaki, Nagisa Kanetake, Yuki Iwashita, Saori Yoshimura, Tamami Kawakami, Terunobu Ishihara, Tomoko Okuda, Kasei Kog. Angular dependence correction of MatriXX and its application to composite dose verification. Journal of applied clinical medical physics. vol 13. issue 5. 2013-01-25. PMID:22955651. for clinical treatment plans, matrixx with angular correction agreed well with dose distributions calculated by the treatment planning system (tps) for gamma evaluation at 3% and 3 mm. 2013-01-25 2023-08-12 Not clear
David S Followill, Stephen F Kry, Lihong Qin, Jessica Lowenstein, Andrea Molineu, Paola Alvarez, Jose Francisco Aguirre, Geoffrey S Ibbot. The Radiological Physics Center's standard dataset for small field size output factors. Journal of applied clinical medical physics. vol 13. issue 5. 2013-01-25. PMID:22955664. within the treatment planning system's (tps) dose calculation algorithm, various unique small field dosimetry parameters are essential, such as multileaf collimator modeling and field size dependence of the output. 2013-01-25 2023-08-12 Not clear
David S Followill, Stephen F Kry, Lihong Qin, Jessica Lowenstein, Andrea Molineu, Paola Alvarez, Jose Francisco Aguirre, Geoffrey S Ibbot. The Radiological Physics Center's standard dataset for small field size output factors. Journal of applied clinical medical physics. vol 13. issue 5. 2013-01-25. PMID:22955664. as a part of the on-site audit, the rpc measures the small field size output factors as might be used in imrt treatments, and compares the resulting field size dependent output factors to values calculated by the institution's treatment planning system (tps). 2013-01-25 2023-08-12 Not clear
Mammo Yewondwosse. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 37. issue 3. 2013-01-15. PMID:22189031. the purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (qa) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (tps) and treatment delivery console computers. 2013-01-15 2023-08-12 Not clear
Mammo Yewondwosse. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 37. issue 3. 2013-01-15. PMID:22189031. the treatment planning system (tps) (oncentra brachy version 3.3, nucletron bv, veenendaal, the netherlands) dose distribution was calculated on the computed tomography (ct) scan of this phantom. 2013-01-15 2023-08-12 Not clear
Iqbal Al Amri, Ramamoorthy Ravichandran, Somangili Satyamoorthi Sivakumar, Johnson Pichi Binukumar, Chirayathmanjiyil Antony Davis, Zakia Al Rahbi, Khalsa Al Shukeili, Fatima Al Kind. Radiotherapy pre-treatment dose validation: A second verification of monitor units (MU) with a commercial software. Journal of medical physics. vol 37. issue 4. 2013-01-08. PMID:23293456. dcms was validated with treatment planning system (tps) (eclipse 6.5 version, varian, usa) separately. 2013-01-08 2023-08-12 Not clear
L Conte, C Mordacchini, L Pozzi, C Vit. An empirical calibration method for an a-Si portal imaging device: applications in pretreatment verification of IMRT. La Radiologia medica. vol 117. issue 6. 2013-01-07. PMID:22430680. the method is independent of data contained in the multileaf collimator (mlc) leaf-motion files and of any calculations made by the treatment planning system (tps). 2013-01-07 2023-08-12 Not clear
J-H Kim, R Hill, Z Kunci. Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study. Australasian physical & engineering sciences in medicine. vol 35. issue 3. 2013-01-03. PMID:22736310. in this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (tps) calculations, relative to benchmark monte carlo (mc) doses calculated at 70 μm for a 6 mv, 10 × 10 cm clinical radiotherapy beam. 2013-01-03 2023-08-12 Not clear