All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
A G Livingstone, S B Crowe, S Sylvander, T Kair. Clinical implementation of a Monte Carlo based independent TPS dose checking system. Physical and engineering sciences in medicine. vol 43. issue 3. 2021-07-06. PMID:32780274. agreement between the tps and mc calculation was an improvement on agreement between radcalc and the tps, with differences ranging from 1.2 to 5.5% between radcalc and the treatment planning system (tps), and 0.1-1.7% between mc and tps. 2021-07-06 2023-08-13 Not clear
L R J Day, M Donzelli, P Pellicioli, L M L Smyth, M Barnes, S Bartzsch, J C Crosbi. A commercial treatment planning system with a hybrid dose calculation algorithm for synchrotron radiotherapy trials. Physics in medicine and biology. vol 66. issue 5. 2021-06-28. PMID:33373979. however, before veterinary trials can commence, a computerised treatment planning system (tps) is required, which can quickly and accurately calculate the synchrotron x-ray dose through patient ct images. 2021-06-28 2023-08-13 Not clear
Tanya Kairn, Alexander G Livingstone, Scott B Crow. Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 78. 2021-06-24. PMID:33035927. given the substantial literature on the use of monte carlo (mc) simulations to verify treatment planning system (tps) calculations of radiotherapy dose in heterogeneous regions, such as head and neck and lung, this study investigated the potential value of running mc simulations of radiotherapy treatments of nominally homogeneous pelvic anatomy. 2021-06-24 2023-08-13 Not clear
Shiva Zarifi, Hadi Taleshi Ahangari, Sayyed Bijan Jia, Mohammad Ali Tajik-Mansoury, Milad Najafzade. GATE MODELING OF LATERAL SCATTERING OF PROTON PENCIL BEAMS. Radiation protection dosimetry. vol 189. issue 1. 2021-06-23. PMID:32112096. in the next step, it was shown that the beam halo can be described by adding a supplementary gaussian function to the standard single-gaussian model, which currently is used by treatment planning systems (tps). 2021-06-23 2023-08-13 Not clear
Pradip Kumar, Sunil Dutt Sharma, Bhushan Dhabekar, Devesh Ramdhar Mishra, Narender Singh Rawat, Sonal Kadam, Suresh Chaudhari, Rakesh Mohan Chandola, Sadhana Agrawa. PATIENT-SPECIFIC DOSIMETRY USING IN-HOUSE DEVELOPED OSL DISC DOSEMETERS. Radiation protection dosimetry. vol 189. issue 1. 2021-06-23. PMID:32140728. doses measured by osl discs were found comparable to ionisation chamber and gafchromic ebt3 film measured values and radiotherapy treatment planning system (tps) calculated dose values in all the cases. 2021-06-23 2023-08-13 Not clear
Xiaotian Huang, Hong Quan, Bo Zhao, Wing Zhou, Charles Chen, Yan Che. A plan template-based automation solution using a commercial treatment planning system. Journal of applied clinical medical physics. vol 21. issue 5. 2021-06-21. PMID:32180351. the purpose of this study was to develop an auto-planning platform to be interfaced with a commercial treatment planning system (tps). 2021-06-21 2023-08-13 Not clear
Emil Schüler, Anthony Lo, Cynthia F Chuang, Scott G Soltys, Erqi L Pollom, Lei Wan. Clinical impact of the VOLO optimizer on treatment plan quality and clinical treatment efficiency for CyberKnife. Journal of applied clinical medical physics. vol 21. issue 5. 2021-06-21. PMID:32212374. with the recent cyberknife treatment planning system (tps) upgrade from precision 1.0 to precision 2.0, the new volo optimizer was released for plan optimization. 2021-06-21 2023-08-13 Not clear
Sammuel Mamesa, Sornjarod Oonsiri, Taweap Sanghangthum, Sumalee Yabsantia, Sivalee Suriyape. The impact of corrected field output factors based on IAEA/AAPM code of practice on small-field dosimetry to the calculated monitor unit in eclipse™ treatment planning system. Journal of applied clinical medical physics. vol 21. issue 5. 2021-06-21. PMID:32237215. the objective of this study was to investigate the effect of field output factors (fofs) according to the current protocol for small-field dosimetry in conjunction to treatment planning system (tps) commissioning. 2021-06-21 2023-08-13 Not clear
Wenlong Xia, Fei Han, Jiayun Chen, Junjie Miao, Jianrong Da. Personalized setting of plan parameters using feasibility dose volume histogram for auto-planning in Pinnacle system. Journal of applied clinical medical physics. vol 21. issue 7. 2021-06-21. PMID:32363757. the personalized setting of plan parameters in the auto-planning module of the pinnacle treatment planning system (tps) using the planiq feasibility tool was evaluated for lung cancer conventional fractionated radiotherapy (cfrt). 2021-06-21 2023-08-13 Not clear
Jeffrey E Snyder, Joël St-Aubin, Sridhar Yaddanapudi, Amanda Boczkowski, David A P Dunkerley, Stephen A Graves, Daniel E Hye. Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience. Journal of applied clinical medical physics. vol 21. issue 7. 2021-06-21. PMID:32432405. multileaf collimator positional accuracy was within 1.0 mm, the measured radiation isocenter walkout was 0.20 mm, and the coincidence between mr and mv isocenter was 1.06 mm, which is accounted for in the treatment planning system (tps). 2021-06-21 2023-08-13 Not clear
Yanhua Duan, Wutian Gan, Hao Wang, Hua Chen, Hengle Gu, Yan Shao, Aihui Feng, Yanchen Ying, Xiaolong Fu, Chenchen Zhang, Zhiyong Xu, Ning Jeff Yu. On the optimal number of dose-limiting shells in the SBRT auto-planning design for peripheral lung cancer. Journal of applied clinical medical physics. vol 21. issue 9. 2021-06-21. PMID:32700823. the number of dose-limiting shells in the optimization process is one of the key factors determining the quality of stereotactic body radiotherapy (sbrt) auto-planning in the pinnacle treatment planning system (tps). 2021-06-21 2023-08-13 Not clear
Ce Han, Jinling Yi, Kecheng Zhu, Yongqiang Zhou, Yao Ai, Xiaomin Zheng, Congying Xie, Xiance Ji. Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 21. issue 11. 2021-06-21. PMID:33001540. independent treatment planning system (tps) check with mobius3d software, log files based quality assurance (qa) with mobiusfx, and phantom measurement-based qa with arccheck were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwent volumetric modulated arc therapy (vmat). 2021-06-21 2023-08-13 Not clear
Ce Han, Jinling Yi, Kecheng Zhu, Yongqiang Zhou, Yao Ai, Xiaomin Zheng, Congying Xie, Xiance Ji. Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 21. issue 11. 2021-06-21. PMID:33001540. for the dosimetric differences in planning target volume (ptv) coverage, there was no significant difference among tps vs. mobius3d, tps vs. mobiusfx, and tps vs. arccheck. 2021-06-21 2023-08-13 Not clear
Simon K Goodall, Martin A Eber. Recommended dose voxel size and statistical uncertainty parameters for precision of Monte Carlo dose calculation in stereotactic radiotherapy. Journal of applied clinical medical physics. vol 21. issue 12. 2021-06-21. PMID:33124741. in this investigation, 30 volumetric modulated arc therapy (vmat) stereotactic radiotherapy (srt) treatment plans, 10 brain, 10 lung, and 10 spine were calculated in the monaco 5.11.02 treatment planning system (tps). 2021-06-21 2023-08-13 Not clear
Dominic Maes, Martin Janson, Rajesh Regmi, Alexander Egan, Anatoly Rosenfeld, Charles Bloch, Tony Wong, Jatinder Sain. Validation and practical implementation of seated position radiotherapy in a commercial TPS for proton therapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 80. 2021-06-21. PMID:33189048. this work aims to validate new 6d couch features and their implementation for seated radiotherapy in raystation (rs) treatment planning system (tps). 2021-06-21 2023-08-13 Not clear
Anna Delana, Agnese Barbareschi, Rita Consorti, Maria Daniela Falc. Dose calculation accuracy in proximity of a pacemaker: A multicenter study with threecommercial treatment planning systems. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 80. 2021-06-21. PMID:33190076. this study compares treatment planning system (tps) out of field dose calculation on a pacemaker (pmk) during external beam radiotherapy treatment. 2021-06-21 2023-08-13 Not clear
Maryam Rostamzadeh, Yoshitomo Ishihara, Mitsuhiro Nakamura, I Antoniu Popescu, Ante Mestrovic, Ermias Gete, Roberto Fedrigo, Alanah Mary Bergma. Monte Carlo simulation of 6-MV dynamic wave VMAT deliveries by Vero4DRT linear accelerator using EGSnrc moving sources. Journal of applied clinical medical physics. vol 21. issue 12. 2021-06-21. PMID:33219743. dwa treatment plans generated from raystation (raysearch) treatment planning system (tps) are simulated on voxelized (2.5 mm 2021-06-21 2023-08-13 Not clear
Amarjit Saini, Chris Tichacek, William Johansson, Gage Redler, Geoffrey Zhang, Eduardo G Moros, Muqeem Qayyum, Vladimir Feygelma. Unlocking a closed system: dosimetric commissioning of a ring gantry linear accelerator in a multivendor environment. Journal of applied clinical medical physics. vol 22. issue 2. 2021-06-21. PMID:33452738. the halcyon™ platform is self-contained, combining a treatment planning (eclipse) system tps) with information management and radiation delivery components. 2021-06-21 2023-08-13 Not clear
Julie Colnot, Sofia Zefkili, Régine Gschwind, Christelle Hue. Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment. Journal of applied clinical medical physics. vol 22. issue 3. 2021-06-21. PMID:33547766. secondly, the accuracy of treatment planning systems (tps) for out-of-field calculation is evaluated. 2021-06-21 2023-08-13 Not clear
Per H Halvorsen, Navneeth Hariharan, Zackary T Morelli, Ileana N Iftimi. Modeling of kyphoplasty cement for accurate dose calculations. Journal of applied clinical medical physics. vol 22. issue 3. 2021-06-21. PMID:33599374. we have determined the optimal method for modeling kyphoplasty cement to enable accurate dose calculations in the eclipse treatment planning system (tps). 2021-06-21 2023-08-13 Not clear