Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Jacob Adams, Kirk Luca, Xiaofeng Yang, Pretesh Patel, Ashesh Jani, Justin Roper, Jiahan Zhan. Plan Quality Analysis of Automated Treatment Planning Workflow With Commercial Auto-Segmentation Tools and Clinical Knowledge-Based Planning Models for Prostate Cancer. Cureus. vol 15. issue 7. 2023-08-02. PMID:37529805. |
the results indicate that an automated volumetric modulated arc therapy (vmat) prostate planning workflow can consistently achieve high plan quality. |
2023-08-02 |
2023-08-14 |
Not clear |
Beata Czeremszynska, Joanna Socha, Anna Rygielska, Agnieszka Walewska, Marta Gabor, Dorota Pruska-Pich, Karolina Osowiecka, Lucyna Kepk. Dosimetric comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy for free-breathing whole-breast irradiation: A planning study. Indian journal of cancer. vol 60. issue 2. 2023-08-02. PMID:37530251. |
dosimetric comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy for free-breathing whole-breast irradiation: a planning study. |
2023-08-02 |
2023-08-14 |
Not clear |
Beata Czeremszynska, Joanna Socha, Anna Rygielska, Agnieszka Walewska, Marta Gabor, Dorota Pruska-Pich, Karolina Osowiecka, Lucyna Kepk. Dosimetric comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy for free-breathing whole-breast irradiation: A planning study. Indian journal of cancer. vol 60. issue 2. 2023-08-02. PMID:37530251. |
we performed a radiotherapy planning study to establish if the use of intensity-modulated radiation therapy (imrt) or volumetric-modulated arc therapy (vmat) allows for better sparing of the heart and its subvolumes than the three-dimensional conformal radiation therapy (3d-crt), and how these attempts affect the dose delivered to the other organs. |
2023-08-02 |
2023-08-14 |
Not clear |
Iga Racka, Karolina Majewska, Janusz Winiecki, Karolina Kilu. Hybrid planning techniques for early-stage left-sided breast cancer: dose distribution analysis and estimation of projected secondary cancer-relative risk. Acta oncologica (Stockholm, Sweden). 2023-07-30. PMID:37516978. |
the purpose of this study was to evaluate three techniques of irradiation of left-sided breast cancer patients, three-dimensional conformal radiotherapy (3d-crt), hybrid intensity-modulated radiotherapy (h-imrt), and hybrid volumetric-modulated arc therapy (h-vmat, h-arc), in terms of dose distribution in the planning target volume (ptv) and organs at risk (oars). |
2023-07-30 |
2023-08-14 |
Not clear |
Souha Aouadi, S A Yoganathan, Tarraf Torfeh, Satheesh Paloor, Palmira Caparrotti, Rabih Hammoud, Noora Al-Hammad. Generation of Synthetic CT from CBCT using Deep Learning Approaches for Head and Neck Cancer Patients. Biomedical physics & engineering express. 2023-07-25. PMID:37489854. |
clinical volumetric modulated arc therapy (vmat) plans were copied from pct to registered cbct and sct and dosimetric analysis was performed by comparing dose volume histogram (dvh) parameters of planning target volumes (ptvs) and organs at risk (oars). |
2023-07-25 |
2023-08-14 |
Not clear |
Shikha Goyal, Poorva Vias, Kannan Periasamy, Renu Madan, Gaurav Trivedi, Sudheer Kumar Devana, Himani Prashar, Divya Khosl. Delineating and sparing the ileal conduit in adjuvant radiotherapy for bladder cancer with modulated radiotherapy. Journal of cancer research and therapeutics. vol 19. issue 3. 2023-07-20. PMID:37470602. |
we undertook a prospective planning study to describe the delineation of ileal conduit (ic) loop on radiotherapy planning computed tomography (rtp ct) scan as an organ at risk (oar) and its sparing using volumetric modulated arc therapy (vmat) during adjuvant irradiation of bladder malignancies. |
2023-07-20 |
2023-08-14 |
Not clear |
Nathan Clements, Nolan Esplen, Magdalena Bazalova-Carte. A feasibility study of ultra-high dose rate mini-GRID therapy using very-high-energy electron beams for a simulated pediatric brain case. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 112. 2023-07-16. PMID:37454482. |
multi-directional vhee treatments with and without mini-grid-fractionation were compared to a clinical 6 mv volumetric modulated arc therapy (vmat) plan for a pediatric glioblastoma patient using dose-volume histograms, volume-averaged dose rates in critical patient structures, and planning target volume d98s. |
2023-07-16 |
2023-08-14 |
Not clear |
Thomas Bortfeld, Susu Ya. Our journeys through the fascinating world of proton radiation therapy. Medical physics. vol 50 Suppl 1. 2023-07-12. PMID:36502491. |
over this time period, the authors' research and development aimed at an improved understanding of the physical benefits of intensity-modulated proton therapy and arc therapy, treatment planning and optimization to take proton-specific uncertainties into account, and imaging to measure the proton range in the patient. |
2023-07-12 |
2023-08-16 |
Not clear |
Chao Li, Haifeng Luo, Wenli Song, Yan Hu, Jingjing Li, Zhiqiang Ca. Dosimetric comparison of four radiotherapy techniques for stage III non‑small cell lung cancer. Oncology letters. vol 26. issue 2. 2023-07-10. PMID:37427336. |
the present study was implemented to compare the dosimetric parameters of the target dose coverage and critical structures in the treatment planning of four radiotherapy techniques [namely, three-dimensional conformal radiation therapy (3d-crt), intensity-modulated radiation therapy (imrt), hybrid imrt (h-imrt) and volumetric-modulated arc therapy (vmat)] for stage iii non-small cell lung cancer (nsclc) qualified plans for medical physicists, therapists and physicians. |
2023-07-10 |
2023-08-14 |
Not clear |
Haitao Sun, Ying Liu, Ling Yuan, Ning Wan. Dosimetry study of Auto-VMAT planning and Manual-VMAT planning based on Pinnacle3 9.10 in radiotherapy for cervical cancer. Medicine. vol 102. issue 26. 2023-06-30. PMID:37390285. |
the purpose of this study was to compare the dose distribution characteristics of automatic volume-modulated arc therapy (auto-vmat) planning and manual volume-modulated arc therapy (manual-vmat) planning of philips pinnacle3 9.10 planning system, to provide a basis for optimal radiation therapy planning for cervical cancer. |
2023-06-30 |
2023-08-14 |
human |
John D Lincoln, R Lee MacDonald, Alasdair Syme, Christopher G Thoma. Static couch non-coplanar arc selection optimization for lung SBRT treatment planning. Physics in medicine and biology. 2023-06-27. PMID:37369237. |
static couch non-coplanar arc selection optimization for lung sbrt treatment planning. |
2023-06-27 |
2023-08-14 |
Not clear |
Rebecca Frederick, Lukas Van Dyke, Alana Hudson, Greg Pierc. Advanced automated treatment planning for total body irradiation: Implementation and effects on standardization. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 112. 2023-06-25. PMID:37356420. |
this work describes the automation of our volumetric modulated arc therapy (vmat) total body irradiation (tbi) treatment planning. |
2023-06-25 |
2023-08-14 |
Not clear |
Pınar Dursun, Linda Hong, Gourav Jhanwar, Qijie Huang, Ying Zhou, Jie Yang, Hai Pham, Laura Cervino, Jean M Moran, Joseph O Deasy, Masoud Zarepishe. Automated VMAT treatment planning using sequential convex programming: algorithm development and clinical implementation. Physics in medicine and biology. 2023-06-21. PMID:37343584. |
to develop and clinically implement a fully automated treatment planning system for volumetric modulated arc therapy (vmat).
approach: we solve two constrained optimization problems sequentially. |
2023-06-21 |
2023-08-14 |
Not clear |
Zhe Zhang, Shou Yu, Feng Peng, Zhibo Tan, Lei Zhang, Daming Li, Pengfei Yang, Zhaoming Peng, Xin Li, Chunfeng Fang, Yuenan Wang, Yajie Li. Advantages and robustness of partial VMAT with prone position for neoadjuvant rectal cancer evaluated by CBCT-based offline adaptive radiotherapy. Radiation oncology (London, England). vol 18. issue 1. 2023-06-17. PMID:37330508. |
this study aims to explore the advantages and robustness of the partial arc combined with prone position planning technique for radiotherapy in rectal cancer patients. |
2023-06-17 |
2023-08-14 |
Not clear |
Timothy D Keiper, Kelly Kisling, Patricia Hua, Ryan P Mange. Comparing brass mesh to tissue equivalent bolus materials for volumetric modulated arc therapy chest wall irradiation. Journal of applied clinical medical physics. 2023-06-08. PMID:37287131. |
to compare the superficial dose when using brass mesh bolus (bmb), no bolus, or 3 mm tissue-equivalent bolus with a pseudo-flash volumetric modulated arc therapy (vmat) breast treatment planning technique. |
2023-06-08 |
2023-08-14 |
Not clear |
Rebecca Barrett, Rob Hale, Nishele Lenards, Ashley Hunzeker, Sabrina Zeile. Improved planning efficiency in multiple brain lesion SRS VMAT cases using Eclipse scripting. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2023-06-04. PMID:37271709. |
the purpose of this study was to determine if scripting could improve treatment planning efficiency for multiple brain lesion stereotactic radiosurgery (srs) volumetric arc therapy cases by reducing planning time commitment. |
2023-06-04 |
2023-08-14 |
Not clear |
Yoshihiro Ueda, Jun-Ichi Fukunaga, Tatsuya Kamima, Yumiko Shimizu, Kazuki Kubo, Hiroshi Doi, Hajime Monze. Standardization of knowledge-based volumetric modulated arc therapy planning with a multi-institution model (broad model) to improve prostate cancer treatment quality. Physical and engineering sciences in medicine. 2023-05-29. PMID:37247102. |
standardization of knowledge-based volumetric modulated arc therapy planning with a multi-institution model (broad model) to improve prostate cancer treatment quality. |
2023-05-29 |
2023-08-14 |
Not clear |
Shingo Ohira, Toshiki Ikawa, Shoki Inui, Naoyuki Kanayama, Yoshihiro Ueda, Masayoshi Miyazaki, Teiji Nishio, Masahiko Koizumi, Koji Konish. Improvement of target coverage using automated non-coplanar volumetric modulated arc therapy planning in stereotactic radiotherapy for cervical metastatic spinal tumors. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2023-05-18. PMID:37202230. |
improvement of target coverage using automated non-coplanar volumetric modulated arc therapy planning in stereotactic radiotherapy for cervical metastatic spinal tumors. |
2023-05-18 |
2023-08-14 |
Not clear |
Yun Zhang, Yuling Huang, Jiafan Lin, Shenggou Ding, Xiaochang Gong, Qiegen Liu, Changfei Gon. Multi-isocenter VMAT craniospinal irradiation using feasibility dose-volume histogram-guided auto-planning technique. Journal of radiation research. 2023-05-04. PMID:37141634. |
this study aims to propose a novel treatment planning methodology for multi-isocenter volumetric modulated arc therapy (vmat) craniospinal irradiation (csi) using the special feasibility dose-volume histogram (fdvh)-guided auto-planning (ap) technique. |
2023-05-04 |
2023-08-14 |
Not clear |
Reena Phurailatpam, Muktar Kumar Sah, Tabassum Wadasadawala, Asfiya Khan, Jithin Palottukandy, Umesh Gayake, Jeevanshu Jain, Rajiv Sarin, Rima Pathak, Revathy Krishnamurthy, Kishore Joshi, Jamema Swamida. Can knowledge based treatment planning of VMAT for post-mastectomy locoregional radiotherapy involving internal mammary chain and supraclavicular fossa improve performance efficiency? Frontiers in oncology. vol 13. 2023-04-28. PMID:37114138. |
to validate and evaluate the performance of knowledge-based treatment planning for volumetric modulated arc radiotherapy for post-mastectomy loco-regional radiotherapy. |
2023-04-28 |
2023-08-14 |
Not clear |