All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
E A Martín-Tovar, A H Badillo-Alvarado, L E Cocom-Poot, J L Gaxiola-Sos. Modulated Arc Therapy for hippocampal-avoidance whole brain radiation therapy: planning comparison with intensity modulated Radiation Therapy. Radiation and environmental biophysics. 2024-05-29. PMID:38809486. this study aimed to evaluate the modulated arc therapy (marc) technique as a planning and treatment option for hippocampal sparing whole brain radiotherapy (hs-wbrt) following the radiation therapy oncology group (rtog) 0933 dosimetric criteria. 2024-05-29 2024-06-03 Not clear
Niketa Thakur, Nancy Bansal, Meena Sudan, Abhishek Sharm. Optimising craniospinal irradiation for medulloblastoma: a dosimetric comparison of two VMAT planning methods. Ecancermedicalscience. vol 18. 2024-05-23. PMID:38774570. here the dosimetric advantages of volumetric-modulated arc therapy (vmat) using partial arc and avoidance sectors are compared with each other in planning in adult patients undergoing csi to develop a clinically feasible technique that is both effective and efficient. 2024-05-23 2024-05-27 Not clear
Yongqian Zhang, Weihua Fu, Edward Brandner, Sharon Percinsky, Mary Moran, M Saiful Hu. Minimizing normal tissue low dose bath for left breast Volumetric Modulated Arc Therapy (VMAT) using jaw offset. Journal of applied clinical medical physics. 2024-05-18. PMID:38760907. with proper beam setup and optimization constraints in the treatment planning system, volumetric modulated arc therapy (vmat) can improve target dose coverage and conformity while reducing doses to adjacent structures for whole breast radiation therapy. 2024-05-18 2024-05-27 Not clear
Anjum Nisha, Shambhavi C, Jyothi Nagesh, Sarath S Nai. Comparison between volumetric modulated arc therapy based coplanar and noncoplanar planning for stereotactic body radiation therapy of Comparison between Volumetric Modulated arc Therapy based Coplanar and Noncoplanar Planning for Stereotactic Body Radiation Therapy of Liver. Asian Pacific journal of cancer prevention : APJCP. vol 25. issue 4. 2024-04-29. PMID:38680000. comparison between volumetric modulated arc therapy based coplanar and noncoplanar planning for stereotactic body radiation therapy of comparison between volumetric modulated arc therapy based coplanar and noncoplanar planning for stereotactic body radiation therapy of liver. 2024-04-29 2024-05-01 Not clear
William T Hrinivich, Mahasweta Bhattacharya, Lina Mekki, Todd McNutt, Xun Jia, Heng Li, Daniel Y Song, Junghoon Le. Clinical VMAT machine parameter optimization for localized prostate cancer using deep reinforcement learning. Medical physics. 2024-04-26. PMID:38669457. volumetric modulated arc therapy (vmat) machine parameter optimization (mpo) remains computationally expensive and sensitive to input dose objectives creating challenges for manual and automatic planning. 2024-04-26 2024-04-29 Not clear
Nicola Lambri, Giorgio Longari, Daniele Loiacono, Ricardo Coimbra Brioso, Leonardo Crespi, Carmela Galdieri, Francesca Lobefalo, Giacomo Reggiori, Roberto Rusconi, Stefano Tomatis, Luisa Bellu, Stefania Bramanti, Elena Clerici, Chiara De Philippis, Damiano Dei, Pierina Navarria, Carmelo Carlo-Stella, Ciro Franzese, Marta Scorsetti, Pietro Mancos. Deep learning-based optimization of field geometry for total marrow irradiation delivered with volumetric modulated arc therapy. Medical physics. 2024-04-18. PMID:38634859. a complex field geometry is needed to cover the large planning target volume (ptv) of tmi/tmli with volumetric modulated arc therapy (vmat). 2024-04-18 2024-04-20 Not clear
Heesoo Kim, Jeong-Woo Lee, Semie Hon. Feasibility of Customized Thermoplastic Patient-Specific Helmet Bolus for Scalp Irradiation Using Volumetric-Modulated Arc Therapy Planning. Technology in cancer research & treatment. vol 23. 2024-04-01. PMID:38557213. feasibility of customized thermoplastic patient-specific helmet bolus for scalp irradiation using volumetric-modulated arc therapy planning. 2024-04-01 2024-04-04 Not clear
Motoharu Sasaki, Yuji Nakaguchi, Takeshi Kamomae, Akira Tsuzuki, Soma Sawada, Koki Shibuya, Masataka Oita, Masahide Tominaga, Yuki Tominaga, Hitoshi Ikushim. Comparative analysis of two dose-volume histogram prediction tools for treatment planning in volumetric-modulated arc therapy: A multi-planner study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-03-31. PMID:38556402. comparative analysis of two dose-volume histogram prediction tools for treatment planning in volumetric-modulated arc therapy: a multi-planner study. 2024-03-31 2024-04-03 Not clear
Hannah Hering, Beth Effeney, Carole Brady, Catriona Hargrav. An evaluation of ankle and foot bolus in paediatric modulated arc total body irradiation (MATBI). Journal of medical radiation sciences. 2024-03-12. PMID:38468597. this retrospective planning study aimed to evaluate the role of bolus in achieving dose uniformity in the ankles and feet in paediatric patients undergoing modulated arc total body irradiation (matbi) treatment and to identify patient factors that may negate or warrant its use. 2024-03-12 2024-03-14 Not clear
Wei-Ta Tsai, Hui-Ling Hsieh, Shih-Kai Hung, Chi-Fu Zeng, Ming-Fen Lee, Po-Hao Lin, Chia-Yi Lin, Wei-Chih Li, Wen-Yen Chiou, Tung-Hsin W. Dosimetry and efficiency comparison of knowledge-based and manual planning using volumetric modulated arc therapy for craniospinal irradiation. Radiology and oncology. 2024-03-07. PMID:38452341. dosimetry and efficiency comparison of knowledge-based and manual planning using volumetric modulated arc therapy for craniospinal irradiation. 2024-03-07 2024-03-10 Not clear
Christopher Deufel, Christopher Dodoo, James Kavanaugh, Randi Finley, Karen Lang, Kasie Sorenson, Sheri Spreiter, Jamison Brooks, Douglas Moseley, Safia K Ahmed, Michael G Haddock, Daniel Ma, Sean S Park, Ivy A Petersen, Dawn W Owen, Michael P Gram. Automated target placement for VMAT lattice radiation therapy: enhancing efficiency and consistency. Physics in medicine and biology. 2024-02-29. PMID:38422544. an algorithm was developed for automated positioning of lattice points within volumetric modulated arc lattice radiation therapy (vmatlrt) planning. 2024-02-29 2024-03-03 human
So Hyun Park, Hyunsoo Ko, Jinhyun Cho. Effect of Jaw Tracking During Volumetric Modulated Arc Therapy for Facial Non-melanoma Skin Cancer. In vivo (Athens, Greece). vol 38. issue 2. 2024-02-28. PMID:38418154. this study aimed to analyze the dosimetric effects of jaw tracking during volumetric modulated arc therapy (vmat) planning for facial non-melanoma skin cancer (nmsc). 2024-02-28 2024-03-02 Not clear
Viktor Wase, Sophie Wuyckens, John A Lee, Michael Saint-Guillai. The proton arc therapy treatment planning problem is NP-Hard. Computers in biology and medicine. vol 171. 2024-02-23. PMID:38394800. the proton arc therapy treatment planning problem is np-hard. 2024-02-23 2024-02-26 Not clear
Thomas Mann, Nicolas Ploquin, Salman Faruqi, Shaun Loewen, Kundan Thin. Stereotactic Optimized Automated Radiotherapy (SOAR): a novel automated planning solution for multi-metastatic SRS compared to HyperArc™. Biomedical physics & engineering express. 2024-02-16. PMID:38364285. this study compares a novel beam angle optimized volumetric modulated arc therapy (vmat) planning solution for multi-metastatic srs to the commercial solution hyperarc. approach: stereotactic optimized automated radiotherapy (soar) performs automated plan creation by combining collision prediction, beam angle optimization, and dose optimization to produce individualized high-quality srs plans using eclipse scripting. 2024-02-16 2024-02-19 Not clear
Andreyson S Araujo, Rogério M V Silva, Divanizia N Souz. Evaluation of conventional IMRT and VMAT strategies for postmastectomy radiation therapy after immediate implant-based reconstruction using the new ESTRO-ACROP contouring guidelines. Radiation and environmental biophysics. 2024-02-01. PMID:38300284. intensity-modulated radiation therapy (imrt) and volumetric modulated arc therapy (vmat) plans generated with two different treatment planning systems (tpss, eclipse and monaco) were examined. 2024-02-01 2024-02-03 Not clear
Santa Gabriella Bonaccorsi, Thomas Tessonnier, Line Hoeltgen, Eva Meixner, Semi Harrabi, Juliane Hörner-Rieber, Thomas Haberer, Amir Abdollahi, Jürgen Debus, Andrea Mairan. Exploring Helium Ions' Potential for Post-Mastectomy Left-Sided Breast Cancer Radiotherapy. Cancers. vol 16. issue 2. 2024-01-23. PMID:38254899. an explorative treatment planning study involving ten patients, previously treated with vmat (volumetric modulated arc therapy) for 50 gy in 25 fractions for locally advanced, node-positive breast cancer, was carried out using proton pencil beam therapy with a fixed relative biological effectiveness (rbe) of 1.1 and helium therapy with a variable rbe described by the mmkm (modified microdosimetric kinetic model). 2024-01-23 2024-01-25 Not clear
Jyotiman Nath, Gautam Sarm. Split X-jaw Planning Technique of Volumetric Modulated Arc Radiotherapy. Journal of medical physics. vol 48. issue 4. 2024-01-15. PMID:38223790. split x-jaw planning technique of volumetric modulated arc radiotherapy. 2024-01-15 2024-01-17 Not clear
Takaaki Ito, Kazuki Kubo, Hajime Monzen, Yuya Yanagi, Kenji Nakamura, Yusuke Sakai, Yasumasa Nishimur. Overcoming Problems Caused by Offset Distance of Multiple Targets in Single-isocenter Volumetric Modulated Arc Therapy Planning for Stereotactic Radiosurgery. Journal of medical physics. vol 48. issue 4. 2024-01-15. PMID:38223796. overcoming problems caused by offset distance of multiple targets in single-isocenter volumetric modulated arc therapy planning for stereotactic radiosurgery. 2024-01-15 2024-01-17 Not clear
Dominika Plaza, Łukasz Sroka, Klaudia Orzechowska, Krzysztof Ślosare. Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. vol 28. issue 5. 2024-01-05. PMID:38179296. the aim of the study was to answer the question of whether flattening filter (ff) and flattening filter-free (fff) beams can be used alternately in the volumetric modulated arc therapy (vmat) treatment technique, regardless of the size of the irradiated volume [small (s) or large (l) planning target volume (ptv)]. 2024-01-05 2024-01-07 Not clear
Timothy Yau, Jeff Kempe, Stewart Gaed. A four-dimensional dynamic conformal arc approach for real-time tumor tracking: A retrospective treatment planning study. Journal of applied clinical medical physics. 2023-12-26. PMID:38146134. a four-dimensional dynamic conformal arc approach for real-time tumor tracking: a retrospective treatment planning study. 2023-12-26 2023-12-28 Not clear