All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
Nicholas Bastidas, Scott P Bartlet. Optimization of curvilinear mandible distraction using 3-dimensional computer-simulated modeling. The Journal of craniofacial surgery. vol 23. issue 6. 2014-01-09. PMID:23147330. using 3-dimensional computer simulation, the location of the osteotomy and arc of the device can be predetermined, allowing for precise planning and determination of end points. 2014-01-09 2023-08-12 Not clear
Wen-Jing Yin, Ying Sun, Feng Chi, Jian-Lan Fang, Rui Guo, Xiao-Li Yu, Yan-Ping Mao, Zhen-Yu Qi, Ying Guo, Meng-Zhong Liu, Jun M. Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients. Radiation oncology (London, England). vol 8. 2013-12-31. PMID:23547760. this prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (npc) patients undergoing volumetric modulated arc therapy (vmat) using cone-beam computed tomography (cbct) and to thus obtain planning target volume (ptv) margins to effectively guide treatment in the future. 2013-12-31 2023-08-12 Not clear
Jerome Krayenbuehl, Oliver Riesterer, Shaun Graydon, Peter Dimmerling, Stephan Kloeck, Ilja F Cierni. Intensity-modulated radiotherapy and volumetric-modulated arc therapy for malignant pleural mesothelioma after extrapleural pleuropneumonectomy. Journal of applied clinical medical physics. vol 14. issue 4. 2013-12-10. PMID:23835378. comparative planning for intensity-modulated radiotherapy (imrt) and volumetric-modulated arc therapy (vmat) was performed. 2013-12-10 2023-08-12 Not clear
Matthew T Studenski, Voichita Bar-Ad, Joshua Siglin, David Cognetti, Joseph Curry, Madalina Tuluc, Amy S Harriso. Clinical experience transitioning from IMRT to VMAT for head and neck cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 2. 2013-12-04. PMID:23246253. to quantify clinical differences for volumetric modulated arc therapy (vmat) versus intensity modulated radiation therapy (imrt) in terms of dosimetric endpoints and planning and delivery time, twenty head and neck cancer patients have been considered for vmat using nucletron oncentra masterplan delivered via an elekta linear accelerator. 2013-12-04 2023-08-12 Not clear
Katsuyuki Sakanaka, Takashi Mizowaki, Sayaka Sato, Kengo Ogura, Masahiro Hiraok. Volumetric-modulated arc therapy vs conventional fixed-field intensity-modulated radiotherapy in a whole-ventricular irradiation: a planning comparison study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 2. 2013-12-04. PMID:23523303. volumetric-modulated arc therapy vs conventional fixed-field intensity-modulated radiotherapy in a whole-ventricular irradiation: a planning comparison study. 2013-12-04 2023-08-12 Not clear
Ruijiang Li, Lei Xin. An adaptive planning strategy for station parameter optimized radiation therapy (SPORT): Segmentally boosted VMAT. Medical physics. vol 40. issue 5. 2013-12-04. PMID:23635247. conventional volumetric modulated arc therapy (vmat) discretizes the angular space into equally spaced control points during planning and then optimizes the apertures and weights of the control points. 2013-12-04 2023-08-12 Not clear
Ahmar S Abbas, Douglas Moseley, Zahra Kassam, Sun Mo Kim, Charles Ch. Volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer. Journal of applied clinical medical physics. vol 14. issue 3. 2013-12-03. PMID:23652258. volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer. 2013-12-03 2023-08-12 Not clear
Keiichi Nakagawa, Akihiro Haga, Satoshi Kida, Yoshitaka Masutani, Hideomi Yamashita, Wataru Takahashi, Akira Sakumi, Naoya Saotome, Takashi Shiraki, Kuni Ohtomo, Yoshio Iwai, Kiyoshi Yod. 4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT. Journal of radiation research. vol 54. issue 1. 2013-11-14. PMID:22843380. 4d registration and 4d verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam ct. we propose a clinical workflow of stereotactic volumetric modulated arc therapy (vmat) for a lung tumor from planning to tumor position verification using 4d planning computed tomography (ct) and 4d cone-beam ct (cbct). 2013-11-14 2023-08-12 Not clear
Binbin Wu, Dalong Pang, Patricio Simari, Russell Taylor, Giuseppe Sanguineti, Todd McNut. Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study. Medical physics. vol 40. issue 2. 2013-09-16. PMID:23387737. to investigate whether an overlap volume histogram (ovh)-driven planning application using an intensity-modulated radiation therapy (imrt) database can guide and automate volumetric-modulated arc therapy (vmat) planning for head-and-neck cancer. 2013-09-16 2023-08-12 Not clear
Neelam Tyagi, Kai Yang, Raminder Sandhu, Di Yan, Sean S Park, Peter Y Chen, Brian Marple. External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: planning and delivery. Medical physics. vol 40. issue 1. 2013-09-13. PMID:23298074. external beam pulsed low dose radiotherapy using volumetric modulated arc therapy: planning and delivery. 2013-09-13 2023-08-12 Not clear
Neelam Tyagi, Kai Yang, Raminder Sandhu, Di Yan, Sean S Park, Peter Y Chen, Brian Marple. External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: planning and delivery. Medical physics. vol 40. issue 1. 2013-09-13. PMID:23298074. to evaluate the feasibility of planning and delivering pulsed low dose radiotherapy (plrt) using volumetric modulated arc therapy (vmat) on elektalinacs. 2013-09-13 2023-08-12 Not clear
Andrea Holt, Dirk Van Gestel, Mark P Arends, Erik W Korevaar, Danny Schuring, Martina C Kunze-Busch, Rob Jw Louwe, Corine van Vliet-Vroegindewei. Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study. Radiation oncology (London, England). vol 8. 2013-09-03. PMID:23369221. multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study. 2013-09-03 2023-08-12 Not clear
Jens Fleckenstein, Lennart Jahnke, Frank Lohr, Frederik Wenz, Jürgen Hesse. Development of a Geant4 based Monte Carlo Algorithm to evaluate the MONACO VMAT treatment accuracy. Zeitschrift fur medizinische Physik. vol 23. issue 1. 2013-08-22. PMID:22921843. a method to evaluate the dosimetric accuracy of volumetric modulated arc therapy (vmat) treatment plans, generated with the monaco™ (version 3.0) treatment planning system in realistic ct-data with an independent geant4 based dose calculation algorithm is presented. 2013-08-22 2023-08-12 Not clear
Shinichi Tsutsumi, Masako N Hosono, Daisaku Tatsumi, Yoshitaka Miki, Yutaka Masuoka, Ryo Ogino, Kentaro Ishii, Yasuhiko Shimatani, Yukio Mik. Delivery parameter variations and early clinical outcomes of volumetric modulated arc therapy for 31 prostate cancer patients: an intercomparison of three treatment planning systems. TheScientificWorldJournal. vol 2013. 2013-08-20. PMID:23401667. delivery parameter variations and early clinical outcomes of volumetric modulated arc therapy for 31 prostate cancer patients: an intercomparison of three treatment planning systems. 2013-08-20 2023-08-12 Not clear
Shinichi Tsutsumi, Masako N Hosono, Daisaku Tatsumi, Yoshitaka Miki, Yutaka Masuoka, Ryo Ogino, Kentaro Ishii, Yasuhiko Shimatani, Yukio Mik. Delivery parameter variations and early clinical outcomes of volumetric modulated arc therapy for 31 prostate cancer patients: an intercomparison of three treatment planning systems. TheScientificWorldJournal. vol 2013. 2013-08-20. PMID:23401667. we created volumetric modulated arc therapy (vmat) plans for 31 prostate cancer patients using one of three treatment planning systems (tpss)--ergo++, monaco, or pinnacle--and then treated those patients. 2013-08-20 2023-08-12 Not clear
May Teoh, Sabeena Beveridge, Katie Wood, Stephen Whitaker, Elizabeth Adams, Donna Rickard, Tom Jordan, Andrew Nisbet, Catharine H Clar. Volumetric-modulated arc therapy (RapidArc) vs. conventional fixed-field intensity-modulated radiotherapy for ¹⁸F-FDG-PET-guided dose escalation in oropharyngeal cancer: a planning study. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 1. 2013-08-12. PMID:22841937. volumetric-modulated arc therapy (rapidarc) vs. conventional fixed-field intensity-modulated radiotherapy for ¹⁸f-fdg-pet-guided dose escalation in oropharyngeal cancer: a planning study. 2013-08-12 2023-08-12 Not clear
Matthew T Studenski, Xinglei Shen, Yan Yu, Ying Xiao, Wenyin Shi, Tithi Biswas, Maria Werner-Wasik, Amy S Harriso. Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation--a comparison with traditional techniques. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 38. issue 1. 2013-08-12. PMID:22878118. here the dosimetric advantages of intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. 2013-08-12 2023-08-12 Not clear
Wataru Takahashi, Hideomi Yamashita, Satoshi Kida, Yoshitaka Masutani, Akira Sakumi, Kuni Ohtomo, Keiichi Nakagawa, Akihiro Hag. Verification of planning target volume settings in volumetric modulated arc therapy for stereotactic body radiation therapy by using in-treatment 4-dimensional cone beam computed tomography. International journal of radiation oncology, biology, physics. vol 86. issue 3. 2013-07-25. PMID:23562767. verification of planning target volume settings in volumetric modulated arc therapy for stereotactic body radiation therapy by using in-treatment 4-dimensional cone beam computed tomography. 2013-07-25 2023-08-12 Not clear
Wataru Takahashi, Hideomi Yamashita, Satoshi Kida, Yoshitaka Masutani, Akira Sakumi, Kuni Ohtomo, Keiichi Nakagawa, Akihiro Hag. Verification of planning target volume settings in volumetric modulated arc therapy for stereotactic body radiation therapy by using in-treatment 4-dimensional cone beam computed tomography. International journal of radiation oncology, biology, physics. vol 86. issue 3. 2013-07-25. PMID:23562767. to evaluate setup error and tumor motion during beam delivery by using 4-dimensional cone beam computed tomography (4d cbct) and to assess the adequacy of the planning target volume (ptv) margin for lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (vmat-sbrt). 2013-07-25 2023-08-12 Not clear
Valerie Panet-Raymond, Will Ansbacher, Sergei Zavgorodni, Bill Bendorffe, Alan Nichol, Pauline T Truong, Wayne Beckham, Maria Vlachak. Coplanar versus noncoplanar intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment planning for fronto-temporal high-grade glioma. Journal of applied clinical medical physics. vol 13. issue 4. 2013-07-16. PMID:22766954. coplanar versus noncoplanar intensity-modulated radiation therapy (imrt) and volumetric-modulated arc therapy (vmat) treatment planning for fronto-temporal high-grade glioma. 2013-07-16 2023-08-12 Not clear