All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
Yuri Jeong, Sang-wook Lee, Jungwon Kwak, Ilsung Cho, Sang Min Yoon, Jong Hoon Kim, Jin-Hong Park, Eun Kyung Choi, Si Yeol Song, Young Seok Kim, Su Ssan Kim, Ji Hyeon Joo, Seung Do Ah. A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer. Radiation oncology (London, England). vol 9. 2015-06-08. PMID:25175383. to compare dosimetric parameters of volumetric modulated arc therapy (vmat) and non-coplanar intensity modulated radiotherapy (imrt) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (ptv) and the sparing of organs at risk (oar). 2015-06-08 2023-08-13 Not clear
Yu Kuang, Lili Wu, Emily Hirata, Kyle Miyazaki, Miles Sato, Sandi A Kwe. Volumetric modulated arc therapy planning for primary prostate cancer with selective intraprostatic boost determined by 18F-choline PET/CT. International journal of radiation oncology, biology, physics. vol 91. issue 5. 2015-06-03. PMID:25832692. volumetric modulated arc therapy planning for primary prostate cancer with selective intraprostatic boost determined by 18f-choline pet/ct. 2015-06-03 2023-08-13 Not clear
Pamela A Myers, Panayiotis Mavroidis, Nikos Papanikolaou, Sotirios Stathaki. Comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning. Journal of applied clinical medical physics. vol 15. issue 5. 2015-05-18. PMID:25207562. comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning. 2015-05-18 2023-08-13 Not clear
Bradley M Rauschenbach, Luke Mackowiak, Harish K Malhotr. A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy. Journal of applied clinical medical physics. vol 15. issue 5. 2015-05-18. PMID:25207575. this study evaluates three-dimensional conformal radiotherapy (3d crt), volumetric-modulated arc therapy (vmat), and dynamic conformal arc therapy (dcat) planning techniques using dosimetric indices from radiation therapy oncology group (rtog) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (nsclc) using stereotactic body radiotherapy (sbrt). 2015-05-18 2023-08-13 Not clear
Shogo Hatanaka, Seiichi Tamaki, Haruna Endo, Norifumi Mizuno, Naoki Nakamur. Utility of Smart Arc CDR for intensity-modulated radiation therapy for prostate cancer. Journal of radiation research. vol 55. issue 4. 2015-05-15. PMID:24522268. volumetric-modulated arc therapy (vmat) is a widespread intensity-modulated radiation therapy (imrt) method, however, vmat requires adaptation of the radiation treatment planning system (rtps) and linear accelerator (linac); these upgrades are quite expensive. 2015-05-15 2023-08-12 Not clear
Elizabeth Forde, Regina Bromley, Andrew Kneebone, Thomas Ead. A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 39. issue 3. 2015-05-12. PMID:24933317. a class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy. 2015-05-12 2023-08-13 Not clear
Elizabeth Forde, Regina Bromley, Andrew Kneebone, Thomas Ead. A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 39. issue 3. 2015-05-12. PMID:24933317. this study is aimed to test a postprostatectomy volumetric-modulated arc therapy (vmat) planning class solution. 2015-05-12 2023-08-13 Not clear
Daniel Gasic, Lars Ohlhues, N Patrik Brodin, Lotte S Fog, Tobias Pommer, Jens P Bangsgaard, Per Munck Af Rosenschöl. A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer. Acta oncologica (Stockholm, Sweden). vol 53. issue 8. 2015-03-12. PMID:24937551. a treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer. 2015-03-12 2023-08-13 Not clear
Samuel Peters, Hans Schiefer, Ludwig Plasswil. A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse. Radiation oncology (London, England). vol 9. 2015-03-05. PMID:25011529. the newest release of the eclipse (varian) treatment planning system (tps) includes an optimizing engine for elekta volumetric-modulated arc therapy (vmat) planning. 2015-03-05 2023-08-13 Not clear
Cem Onal, Gungor Arslan, Cem Parlak, Serhat Sonme. Comparison of IMRT and VMAT plans with different energy levels using Monte-Carlo algorithm for prostate cancer. Japanese journal of radiology. vol 32. issue 4. 2015-02-19. PMID:24510241. to make dosimetric comparisons of volumetric-modulated arc therapy (vmat) and 7-field intensity-modulated radiotherapy (imrt) with dynamic mlcs using the monaco treatment planning system with monte carlo algorithm. 2015-02-19 2023-08-12 Not clear
David Craft, Mark Bangert, Troy Long, Dávid Papp, Jan Unkelbac. Shared data for intensity modulated radiation therapy (IMRT) optimization research: the CORT dataset. GigaScience. vol 3. issue 1. 2015-02-14. PMID:25678961. the datasets allow researchers to make one-to-one comparisons of algorithms in order to solve various instances of the radiation therapy treatment planning problem in intensity modulated radiation therapy (imrt), including beam angle optimization, volumetric modulated arc therapy and direct aperture optimization. 2015-02-14 2023-08-13 Not clear
Ady Abdellatif, Stewart Gaed. Control point analysis comparison for 3 different treatment planning and delivery complexity levels using a commercial 3-dimensional diode array. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 39. issue 2. 2015-01-29. PMID:24480374. to investigate the use of "control point analysis" (sun nuclear corporation, melbourne, fl) to analyze and compare delivered volumetric-modulated arc therapy (vmat) plans for 3 different treatment planning complexity levels. 2015-01-29 2023-08-12 Not clear
Suresh Rana, ChihYao Cheng, Yuanshui Zheng, Wen Hsi, Omar Zeidan, Niek Schreuder, Carlos Vargas, Gary Larso. Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy. Journal of applied clinical medical physics. vol 15. issue 3. 2015-01-13. PMID:24892333. dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy. 2015-01-13 2023-08-13 Not clear
Suresh Rana, ChihYao Cheng, Yuanshui Zheng, Wen Hsi, Omar Zeidan, Niek Schreuder, Carlos Vargas, Gary Larso. Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy. Journal of applied clinical medical physics. vol 15. issue 3. 2015-01-13. PMID:24892333. the main purposes of this study were to 1) investigate the dosimetric quality of uniform scanning proton therapy planning (uspt) for prostate cancer patients with a metal hip prosthesis, and 2) compare the dosimetric results of uspt with that of volumetric-modulated arc therapy (vmat). 2015-01-13 2023-08-13 Not clear
Yohei Oku, Atsuya Takeda, Naoko Sanuki, Yasunobu Sudo, Yoshikazu Oooka, Yousuke Aoki, Yoshiaki Shimouchi, Ryohei Nishina, Kazuhiro Nomura, Takahisa Eriguchi, Etsuo Kunied. Stereotactic ablative body radiation therapy with dynamic conformal multiple arc therapy for liver tumors: optimal isodose line fitting to the planning target volume. Practical radiation oncology. vol 4. issue 1. 2015-01-07. PMID:24621435. stereotactic ablative body radiation therapy with dynamic conformal multiple arc therapy for liver tumors: optimal isodose line fitting to the planning target volume. 2015-01-07 2023-08-12 Not clear
L Nithya, N Arunai Nambi Raj, Sasikumar Rathinamuthu, Kanika Sharma, Manish Bhushan Pande. Influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in Monaco planning system: A planning study. Journal of medical physics. vol 39. issue 4. 2014-12-19. PMID:25525311. influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in monaco planning system: a planning study. 2014-12-19 2023-08-13 Not clear
Travis J McCaw, John A Micka, Larry A DeWer. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Medical physics. vol 41. issue 5. 2014-12-15. PMID:24784393. three-dimensional (3d) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. 2014-12-15 2023-08-13 human
B Huang, Z Fang, Y Huang, P Lin, Z Che. A dosimetric analysis of volumetric-modulated arc radiotherapy with jaw width restriction vs 7 field intensity-modulated radiotherapy for definitive treatment of cervical cancer. The British journal of radiology. vol 87. issue 1039. 2014-12-09. PMID:24834477. radiation therapy treatment planning was performed to compare the dosimetric difference between volumetric-modulated arc radiotherapy (rapidarc™ v. 10; varian® medical systems, palo alto, ca) and 7-field intensity-modulated radiotherapy (7f-imrt) in the definitive treatment of cervical cancer. 2014-12-09 2023-08-13 Not clear
Eduard Schreibmann, Tim Fo. Prior-knowledge treatment planning for volumetric arc therapy using feature-based database mining. Journal of applied clinical medical physics. vol 15. issue 2. 2014-12-04. PMID:24710446. prior-knowledge treatment planning for volumetric arc therapy using feature-based database mining. 2014-12-04 2023-08-13 Not clear
Eduard Schreibmann, Tim Fo. Prior-knowledge treatment planning for volumetric arc therapy using feature-based database mining. Journal of applied clinical medical physics. vol 15. issue 2. 2014-12-04. PMID:24710446. treatment planning for volumetric arc therapy (vmat) is a lengthy process that requires many rounds of optimizations to obtain the best treatment settings and optimization constraints for a given patient's geometry. 2014-12-04 2023-08-13 Not clear