Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
R Rambaldi, J N Hamburger, M L Geleijnse, D Poldermans, G J Kimman, A A Aiazian, P M Fioretti, F J Ten Cate, J R Roelandt, P W Serruy. Early recovery of wall motion abnormalities after recanalization of chronic totally occluded coronary arteries: a dobutamine echocardiographic, prospective, single-center experience. American heart journal. vol 136. issue 5. 1998-12-02. PMID:9812078. |
we evaluated the early functional results of successful percutaneous recanalization by performing dobutamine stress echocardiography (dse). |
1998-12-02 |
2023-08-12 |
Not clear |
R B Daggubati, S Khanal, M Fallahtafti, R G Pa. Effect of dobutamine stress on left ventricular systolic and diastolic functions in patients with moderate to severe left ventricular dysfunction. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. vol 11. issue 8. 1998-11-06. PMID:9719090. |
dobutamine stress echocardiography (dse) is increasingly used in patients with moderate and severe left ventricular (lv) dysfunction. |
1998-11-06 |
2023-08-12 |
Not clear |
R B Daggubati, S Khanal, M Fallahtafti, R G Pa. Effect of dobutamine stress on left ventricular systolic and diastolic functions in patients with moderate to severe left ventricular dysfunction. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. vol 11. issue 8. 1998-11-06. PMID:9719090. |
this study investigates the effect of dobutamine stress on lv systolic and diastolic performance and peripheral hemodynamics in 177 consecutive patients undergoing dse. |
1998-11-06 |
2023-08-12 |
Not clear |
A Elhendy, R T van Domburg, J J Bax, P R Nierop, M L Geleijnse, M M Ibrahim, J R Roeland. Noninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT. Chest. vol 114. issue 4. 1998-11-06. PMID:9792583. |
noninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mtc sestamibi single-photon emission ct. to compare the accuracy of dobutamine stress echocardiography (dse) and simultaneous 99mtc sestamibi (mibi) single-photon emission ct (spect) imaging for the diagnosis of coronary artery stenosis in women. |
1998-11-06 |
2023-08-12 |
Not clear |
M L Bremer, K H Monahan, V L Stussy, F A Miller, J B Seward, P A Pellikk. Safety of dobutamine stress echocardiography supervised by registered nurse sonographers. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. vol 11. issue 6. 1998-09-09. PMID:9657398. |
dobutamine stress echocardiography (dse) is widely used for the diagnosis and evaluation of coronary artery disease. |
1998-09-09 |
2023-08-12 |
Not clear |
M Previtali, R Fetiveau, L Lanzarini, C Cavalotti, C Klers. Prognostic value of myocardial viability and ischemia detected by dobutamine stress echocardiography early after acute myocardial infarction treated with thrombolysis. Journal of the American College of Cardiology. vol 32. issue 2. 1998-09-01. PMID:9708464. |
the aim of the study was to assess the prognostic value of myocardial viability and ischemia detected by dobutamine stress echocardiography (dse) in patients with acute myocardial infarction (ami) treated with thrombolysis. |
1998-09-01 |
2023-08-12 |
Not clear |
R L Larsen, P M Applegate, D A Dyar, P A Ribeiro, S D Fritzsche, N F Mulla, G S Shirali, M A Kuhn, R E Chinnock, P M Sha. Dobutamine stress echocardiography for assessing coronary artery disease after transplantation in children. Journal of the American College of Cardiology. vol 32. issue 2. 1998-09-01. PMID:9708485. |
the purpose of this study was to determine the feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography (dse) for evaluating posttransplant coronary artery disease (txcad) in children, and to determine the frequency of selected cardiac events after normal or abnormal dse. |
1998-09-01 |
2023-08-12 |
Not clear |
M E Griffin, K Nikookam, M M Teh, H McCann, N M O'Meara, R G Firt. Dobutamine stress echocardiography: false positive scans in proteinuric patients with type 1 diabetes mellitus at high risk of ischaemic heart disease. Diabetic medicine : a journal of the British Diabetic Association. vol 15. issue 5. 1998-07-16. PMID:9609366. |
new techniques for non-invasive cardiac evaluation are now available and one of these, dobutamine stress echocardiography (dse), was studied in subjects with type 1 dm and nephropathy who had no evidence of ihd. |
1998-07-16 |
2023-08-12 |
human |
R Rambaldi, D Poldermans, P M Fioretti, F J ten Cate, W B Vletter, J J Bax, J R Roeland. Usefulness of pulse-wave Doppler tissue sampling and dobutamine stress echocardiography for the diagnosis of right coronary artery narrowing. The American journal of cardiology. vol 81. issue 12. 1998-07-14. PMID:9645889. |
to study the feasibility and diagnostic accuracy of right coronary artery (rca) narrowing by right ventricular (rv) pulse-wave doppler tissue sampling during dobutamine stress echocardiography (dse), 30 patients (mean age 55 +/- 9.5 years, 26 men) with suspected coronary artery disease underwent dse (up to 40 microg/kg/min with additional atropine during submaximum heart rate responses). |
1998-07-14 |
2023-08-12 |
Not clear |
T Hennessy, P Diamond, B Holligan, C O'Keane, J Hurley, M Codd, C McCarthy, H McCann, D Sugru. Correlation of myocardial histologic changes in hibernating myocardium with dobutamine stress echocardiographic findings. American heart journal. vol 135. issue 6 Pt 1. 1998-06-30. PMID:9630098. |
the objective of this study was to correlate histologic changes in hibernating myocardium with dobutamine stress echocardiography (dse). |
1998-06-30 |
2023-08-12 |
Not clear |
K O Akosah, S McDaniel, J S Hanrahan, P K Mohant. Dobutamine stress echocardiography early after heart transplantation predicts development of allograft coronary artery disease and outcome. Journal of the American College of Cardiology. vol 31. issue 7. 1998-06-26. PMID:9626841. |
this study sought to determine the prognostic significance of serial dobutamine stress echocardiography (dse) in new heart transplant recipients and to examine the relation between persistent wall motion abnormalities and the eventual development of coronary artery disease (cad) as assessed by angiography. |
1998-06-26 |
2023-08-12 |
Not clear |
M T Galloway, T G Paglieroni, T Wun, F J Arena, W R Lewi. Platelet activation during dobutamine stress echocardiography. American heart journal. vol 135. issue 5 Pt 1. 1998-05-19. PMID:9588422. |
dobutamine stress echocardiography (dse) is a common, useful test for the evaluation of coronary artery disease. |
1998-05-19 |
2023-08-12 |
Not clear |
Y L Ho, C C Wu, P J Huang, L C Lin, P U Chieng, W J Chen, M F Chen, Y T Le. Assessment of coronary artery disease in women by dobutamine stress echocardiography: comparison with stress thallium-201 single-photon emission computed tomography and exercise electrocardiography. American heart journal. vol 135. issue 4. 1998-04-24. PMID:9539482. |
dobutamine stress echocardiography (dse) is sensitive and specific in detecting myocardial ischemia of male patients. |
1998-04-24 |
2023-08-12 |
Not clear |
T G Hennessy, M B Codd, M S Hennessy, G Kane, C McCarthy, H A McCann, D D Sugru. Comparison of dobutamine stress echocardiography and treadmill exercise electrocardiography for detection of coronary artery disease. Coronary artery disease. vol 8. issue 11-12. 1998-04-14. PMID:9472457. |
excellent diagnostic accuracy has been reported for dobutamine stress echocardiography (dse). |
1998-04-14 |
2023-08-12 |
Not clear |
K O Akosah, P K Mohant. Role of dobutamine stress echocardiography in heart transplant patients. Chest. vol 113. issue 3. 1998-04-03. PMID:9515861. |
the objective of this focused review is to describe the rationale, methods, and potential clinical applications of dobutamine stress echocardiography (dse) in heart transplant recipients. |
1998-04-03 |
2023-08-12 |
Not clear |
Y L Ho, C C Wu, L C Lin, C H Huang, W J Chen, M F Chen, C S Liau, Y T Le. Assessment of the coronary artery disease and systolic dysfunction in hypertensive patients with the dobutamine-atropine stress echocardiography: effect of the left ventricular hypertrophy. Cardiology. vol 89. issue 1. 1998-02-26. PMID:9452158. |
this study was performed to evaluate whether left ventricular hypertrophy (lvh) can influence the diagnostic accuracy of coronary artery disease (cad) using the dobutamine stress echocardiography (dse) in hypertensive patients. |
1998-02-26 |
2023-08-12 |
Not clear |
R Bigi, A Galati, G Curti, C Coletta, R Ricci, F Fedeli, G Occhi, V Ceci, C Fiorentin. Different clinical and prognostic significance of painful and silent myocardial ischemia detected by exercise electrocardiography and dobutamine stress echocardiography after uncomplicated myocardial infarction. The American journal of cardiology. vol 81. issue 1. 1998-02-19. PMID:9462610. |
prevalence and prognostic significance of painful and silent ischemia detected by exercise electrocardiography (ecg) and dobutamine stress echocardiography (dse) were evaluated in 407 consecutive patients recovering from acute myocardial infarction. |
1998-02-19 |
2023-08-12 |
Not clear |
L Ma, L Chen, L Gillam, D D Waters, C Che. Nitroglycerin enhances the ability of dobutamine stress echocardiography to detect hibernating myocardium. Circulation. vol 96. issue 11. 1998-01-06. PMID:9403624. |
a biphasic response of wall thickening with initial improvement and subsequent deterioration during dobutamine stress echocardiography (dse) has been increasingly used for detection of hibernating myocardium. |
1998-01-06 |
2023-08-12 |
Not clear |
A Elhendy, M L Geleijnse, R T van Domburg, P R Nierop, D Poldermans, J J Bax, F J TenCate, Y F Nosir, M M Ibrahim, J R Roeland. Gender differences in the accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery disease. The American journal of cardiology. vol 80. issue 11. 1997-12-30. PMID:9399713. |
the accuracy of dobutamine stress echocardiography (dse) for the diagnosis of coronary artery disease (cad) has not been yet evaluated in women. |
1997-12-30 |
2023-08-12 |
Not clear |
M Takeuchi, Y Miura, T Toyokawa, M Araki, Y Nakashima, A Kuroiw. The comparative diagnostic value of dobutamine stress echocardiography and thallium stress tomography for detecting restenosis after coronary angioplasty. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. vol 8. issue 5 Pt 1. 1997-12-29. PMID:9417213. |
the aim of this study was to compare the diagnostic value of dobutamine stress echocardiography (dse) and stress 201tl single-photon emission computed tomography (spect) for detecting restenosis after ptca. |
1997-12-29 |
2023-08-12 |
Not clear |