Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Andrew J Burger, Hani Al-Sergani, David Wroblesk. False positive ST segment elevation during dobutamine stress echocardiography due to left ventricular hypertrophy. Echocardiography (Mount Kisco, N.Y.). vol 19. issue 2. 2002-06-07. PMID:11926971. |
the significance of st segment elevation in dobutamine stress echocardiography (dse) remains controversial. |
2002-06-07 |
2023-08-12 |
Not clear |
Andrew J Burger, Hani Al-Sergani, David Wroblesk. False positive ST segment elevation during dobutamine stress echocardiography due to left ventricular hypertrophy. Echocardiography (Mount Kisco, N.Y.). vol 19. issue 2. 2002-06-07. PMID:11926971. |
during dse, dobutamine was infused from 5 microg/kg/min up to a maximum of 50 microg/kg/min. |
2002-06-07 |
2023-08-12 |
Not clear |
Bernard Cosyns, Elif Akseki, Guy Van Camp, Danny Schoors, Isabelle Liebens, Danièle Plein, Jean-Luc Vandenbossche, Philippe Franke. Relationship between late potentials and myocardial viability assessed by dobutamine echocardiography in the early postinfarction period. Coronary artery disease. vol 13. issue 2. 2002-05-28. PMID:12004264. |
the aim of the present study was to assess prospectively the possible relationship between lps and myocardial viability detected by dobutamine stress echocardiography (dse) in the early period after myocardial infarction (ami), before hospital discharge. |
2002-05-28 |
2023-08-12 |
Not clear |
K Iwakura, H Ito, N Nishikawa, K Sugimoto, Y Shintani, K Yamamoto, Y Higashino, T Masuyama, M Hori, K Fuji. Use of echocardiography for predicting myocardial viability in patients with reperfused anterior wall myocardial infarction. The American journal of cardiology. vol 85. issue 6. 2002-05-23. PMID:12000051. |
dobutamine stress echocardiography (dse), myocardial contrast echocardiography (mce), and ultrasonic tissue characterization with integrated backscatter are useful methods for assessing myocardial viability in acute myocardial infarction. |
2002-05-23 |
2023-08-12 |
Not clear |
Y Cottin, I L'huillier, O Casasnovas, C Geoffroy, D Caillot, M Zeller, E Solary, H Guy, J E Wol. Dobutamine stress echocardiography identifies anthracycline cardiotoxicity. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. vol 1. issue 3. 2002-04-26. PMID:11916591. |
we assessed the physiological responses of stress echocardiography at low doses of dobutamine (dse) in patients treated with anthracycline. |
2002-04-26 |
2023-08-12 |
Not clear |
T Zaglavara, R Haaverstad, B Cumberledge, T Irvine, H Karvounis, G Parharidis, G Louridas, A Kenn. Dobutamine stress echocardiography for the detection of myocardial viability in patients with left ventricular dysfunction taking beta blockers: accuracy and optimal dose. Heart (British Cardiac Society). vol 87. issue 4. 2002-04-16. PMID:11907003. |
to assess the accuracy of dobutamine stress echocardiography (dse) and the optimal dose of dobutamine to detect myocardial viability in patients with ischaemic left ventricular (lv) dysfunction who are taking beta blockers, using the recovery of function six months artery revascularisation as the benchmark. |
2002-04-16 |
2023-08-12 |
Not clear |
A Klisiewicz, P Michałek, A Witkowski, P Hoffma. [Assessment of myocardial function at infarct zone after PTCA infarct-related artery--a study with tissue Doppler echocardiography]. Polskie Archiwum Medycyny Wewnetrznej. vol 105. issue 5. 2002-03-28. PMID:11865588. |
thirty nine patients (30 male, mean age 53.4 +/- 8.4 yrs) who had mi 13 +/- 6 weeks earlier were qualified for ira angioplasty on the basis of dobutamine stress echocardiography (dse) if a viable myocardium was demonstrated. |
2002-03-28 |
2023-08-12 |
Not clear |
D Yuan, H Kühl, B Nowak, E Kleinhans, H J Kaiser, A Franke, U Büll, P Hanrath, R Hoffman. Pulsed tissue Doppler imaging to assess myocardial viability by quantification of regional myocardial functional reserve. Echocardiography (Mount Kisco, N.Y.). vol 18. issue 8. 2002-03-06. PMID:11801207. |
dobutamine stress echocardiography (dse) is used widely to evaluate myocardial viability, but is limited by the subjective nature of test interpretation. |
2002-03-06 |
2023-08-12 |
Not clear |
D Yuan, H Kühl, B Nowak, E Kleinhans, H J Kaiser, A Franke, U Büll, P Hanrath, R Hoffman. Pulsed tissue Doppler imaging to assess myocardial viability by quantification of regional myocardial functional reserve. Echocardiography (Mount Kisco, N.Y.). vol 18. issue 8. 2002-03-06. PMID:11801207. |
the increase of peak systolic myocardial velocity from baseline to low dose dobutamine was significantly different between segments defined as normal, viable, and nonviable by 2-d dse (2.71 +/- 1.91 cm/sec, 1.86 +/- 2.15 cm/sec, and 0.99 +/- 1.16 cm/sec, respectively; p < 0.001). |
2002-03-06 |
2023-08-12 |
Not clear |
S Morsy, M Zahran, M Usama, K Elkhashab, I Abdel-Azi. Hemodynamic performance of stentless porcine bioprosthesis and mechanical bileaflet prosthesis using dobutamine stress echocardiography. Seminars in thoracic and cardiovascular surgery. vol 13. issue 4 Suppl 1. 2002-03-05. PMID:11805961. |
the objective was to compare the hemodynamic response of the stentless porcine bioprosthesis (sp) and the mechanical bileaflet prosthesis (mb) at rest and during peak exercise using dobutamine stress echocardiography (dse). |
2002-03-05 |
2023-08-12 |
Not clear |
S E Hardt, I Pekrul, A Hansen, M M Gebhard, W Kuebler, H F Kuechere. Differential value of adenosine myocardial contrast echocardiography and dobutamine stress echocardiography in evaluating functional significance of coronary artery stenosis in a porcine model. Basic research in cardiology. vol 96. issue 4. 2002-01-11. PMID:11518198. |
noninvasive detection of flow limiting coronary artery stenosis in clinical routine is a frequent domaine of dobutamine stress echocardiography (dse) visualizing ischemia related regional wall motion abnormalities. |
2002-01-11 |
2023-08-12 |
Not clear |
A Penfornis, C Zimmermann, D Boumal, A Sabbah, N Meneveau, S Gaultier-Bourgeois, J P Bassand, Y Bernar. Use of dobutamine stress echocardiography in detecting silent myocardial ischaemia in asymptomatic diabetic patients: a comparison with thallium scintigraphy and exercise testing. Diabetic medicine : a journal of the British Diabetic Association. vol 18. issue 11. 2002-01-11. PMID:11703435. |
the aim of this study was to compare the efficacy of thallium-201 single-photon emission computed tomography (201tl spect) coupled with exercise stress testing (est), and dobutamine stress echocardiography (dse) in the detection of asymptomatic coronary artery disease. |
2002-01-11 |
2023-08-12 |
Not clear |
M S Dolan, K Riad, A El-Shafei, S Puri, K Tamirisa, M Bierig, J St Vrain, L McKinney, E Havens, K Habermehl, L Pyatt, M Kern, A J Labovit. Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients. American heart journal. vol 142. issue 5. 2002-01-08. PMID:11685180. |
the study evaluates whether optison used during dobutamine stress echocardiography (dse) will improve endocardial border definition and whether this will translate to an improvement in sensitivity and specificity of the test in patients with poor echocardiographic windows. |
2002-01-08 |
2023-08-12 |
Not clear |
P Lancellotti, T Benoit, P Rigo, L A Pierar. Dobutamine stress echocardiography versus quantitative technetium-99m sestamibi SPECT for detecting residual stenosis and multivessel disease after myocardial infarction. Heart (British Cardiac Society). vol 86. issue 5. 2001-12-10. PMID:11602542. |
to compare the relative accuracy of dobutamine stress echocardiography (dse) and quantitative technetium-99m sestamibi single photon emission computed tomography (mibi spect) for detecting infarct related artery stenosis and multivessel disease early after acute myocardial infarction. |
2001-12-10 |
2023-08-12 |
Not clear |
H Honma, Y Kusama, T Matsuzaki, T Ohno, R Nishigaki, K Munakata, H Kishida, T Takan. Resting ultrasonic tissue characterization and dobutamine stress echocardiography for prediction of functional recovery in chronic left ventricular ischemic dysfunction. Japanese circulation journal. vol 65. issue 5. 2001-12-07. PMID:11348040. |
this study was designed to assess the diagnostic accuracy of the percentage of resting systolic wall thickening (wt), dobutamine stress echocardiography (dse), resting cyclic variation of integrated backscatter (ibs-cv), and low-dose dobutamine stress ibs-cv (dse-ib) for the prediction of regional function recovery (rfr) in patients with chronic left ventricular (lv) ischemic dysfunction. |
2001-12-07 |
2023-08-12 |
Not clear |
R Bigi, L Cortigiani, A Desideri, P Colombo, C Sponzilli, J J Bax, C Fiorentin. Clinical and angiographic correlates of dobutamine-induced wall motion patterns after myocardial infarction. The American journal of cardiology. vol 88. issue 9. 2001-12-07. PMID:11703986. |
the ability of different dobutamine-induced wall motion patterns to define the anatomic status of the infarct-related artery (ira) was evaluated in 159 patients who underwent dobutamine stress echocardiography (dse) and coronary angiography 10 +/- 2 and 18 +/- 3 days, respectively, after hospital admission. |
2001-12-07 |
2023-08-12 |
Not clear |
N Espinola-Zavaleta, N Gómez-Núñez, P Y Chávez, G Sahagun-Sánchez, C Keirns, J M Casanova, A Romero-Cárdenas, F J Roldán, J Vargas-Barró. Evaluation of the response to pharmacological stress in chronic aortic regurgitation. Echocardiography (Mount Kisco, N.Y.). vol 18. issue 6. 2001-12-04. PMID:11567594. |
we evaluated the hemodynamic response of patients with chronic aortic regurgitation and decreased ejection fraction (ef), mean value +/- sd (37 +/- 9), to dobutamine stress echocardiography (dse). |
2001-12-04 |
2023-08-12 |
Not clear |
A J Rainbird, S L Mulvagh, J K Oh, R B McCully, K W Klarich, C Shub, D W Mahoney, P A Pellikk. Contrast dobutamine stress echocardiography: clinical practice assessment in 300 consecutive patients. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. vol 14. issue 5. 2001-08-30. PMID:11337683. |
in this study we compared non-contrast imaging with contrast imaging of the left ventricle during dobutamine stress echocardiography (dse). |
2001-08-30 |
2023-08-12 |
Not clear |
A Lassnigg, M Wutte, G Grubhofer, O Chevtchik, B Podesser, N Simon-Kupilik, T Wild, M Hiesmayr, R Seitelberge. Diltiazem versus nitroglycerin for myocardial protection following coronary artery bypass grafting as assessed by dobutamine stress echocardiography. Wiener klinische Wochenschrift. vol 113. issue 11-12. 2001-08-30. PMID:11467090. |
dobutamine stress echocardiography (dse) is an established technique that combines inotropic stimulation with real-time myocardial imaging and delineates normal and abnormal regional contraction patterns. |
2001-08-30 |
2023-08-12 |
Not clear |
K Yoshinaga, K Morita, S Yamada, K Komuro, C Katoh, Y Ito, Y Kuge, T Kohya, A Kitabatake, N Tamak. Low-dose dobutamine electrocardiograph-gated myocardial SPECT for identifying viable myocardium: comparison with dobutamine stress echocardiography and PET. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. vol 42. issue 6. 2001-08-09. PMID:11390545. |
this study compared the accuracy of low-dose dobutamine stress gated myocardial spect (ds spect) with the accuracy of dobutamine stress echocardiography (dse) and resting perfusion spect for the identification of viable myocardium in patients with previous myocardial infarction. |
2001-08-09 |
2023-08-12 |
Not clear |