Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Yusuke Okanoue, Masahiko Ikeuchi, Shogo Takaya, Masashi Izumi, Koji Aso, Teruhiko Kawakam. Chronological changes in functional cup position at 10 years after total hip arthroplasty. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 27. issue 5. 2019-08-19. PMID:28218372. |
this study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (tha), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. |
2019-08-19 |
2023-08-13 |
Not clear |
Biao Zhu, Changzheng Su, Yeteng He, Xingyu Chai, Zhen Li, Zhenyang Hou, Tengteng Lou, Xinfeng Ya. Combined anteversion technique in total hip arthroplasty for Crowe IV developmental dysplasia of the hip. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 27. issue 6. 2019-08-19. PMID:28574117. |
if the cup is fixed with normal anteversion, the anterior rim will be excessively exposed, which reduces the contact areas of the cup and bone, affects prosthesis stability, and leads to iliopsoas tendinitis and persistent hip pain after tha. |
2019-08-19 |
2023-08-13 |
Not clear |
Gens P Goodman, Nitin Goyal, Nancy L Parks, Robert H Hopper, William G Hamilto. Intraoperative fluoroscopy with a direct anterior approach reduces variation in acetabular cup abduction angle. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 27. issue 6. 2019-08-19. PMID:28731487. |
the purpose of this study was to compare acetabular cup position for 2 cohorts of total hip arthroplasty (tha) patients who had a direct anterior approach. |
2019-08-19 |
2023-08-13 |
Not clear |
Mohammad Ali Alzohiry, Mohammad Kamal Abdelnasser, Mohamed Moustafa, Mohamed Mahran, Hatem Bakr, Yaser Khalifa, Ahmed Abelaal, Haisam Atta, Galal Zaki Sai. Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version. International orthopaedics. vol 42. issue 12. 2019-08-12. PMID:29869012. |
acetabular cup version is crucial for successful total hip arthroplasty (tha). |
2019-08-12 |
2023-08-13 |
Not clear |
Dong Wang, Huawu Zhang, Shui Sun, Yonggang Zhou, Jiying Chen, Libo Ha. Pelvic height planning versus conventional templating in preoperative planning of acetabulum cup size for THA. Acta orthopaedica Belgica. vol 84. issue 4. 2019-08-12. PMID:30879447. |
pelvic height planning versus conventional templating in preoperative planning of acetabulum cup size for tha. |
2019-08-12 |
2023-08-13 |
Not clear |
Yuta Sakemi, Keisuke Komiyama, Kensei Yoshimoto, Kyohei Shiomoto, Miho Iwamoto, Yasuharu Nakashim. How does anteroposterior cup placement affect bone coverage and range of motion in primary total hip arthroplasty for hip dysplasia? Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. vol 24. issue 2. 2019-07-24. PMID:30243518. |
we examined whether posterior cup placement affected the postoperative range of motion (rom) in primary total hip arthroplasty (tha). |
2019-07-24 |
2023-08-13 |
Not clear |
Guoyan Zhen. Gravity-Assisted Navigation System for Total Hip Arthroplasty. Advances in experimental medicine and biology. vol 1093. 2019-07-24. PMID:30306482. |
in this chapter we propose a new system that allows reliable acetabular cup placement in total hip arthroplasty (tha) when the surgery is operated in lateral approach. |
2019-07-24 |
2023-08-13 |
Not clear |
Evan R Deckard, R Michael Meneghin. Femoral Head Penetration Rates of Second-Generation Sequentially Annealed Highly Cross-Linked Polyethylene at Minimum Five Years. The Journal of arthroplasty. vol 34. issue 4. 2019-07-15. PMID:30609952. |
highly cross-linked polyethylene (hxlpe) liners in total hip arthroplasty (tha) have demonstrated decreased wear rates, resilience to cup orientation, and reduced osteolysis compared to conventional polyethylene. |
2019-07-15 |
2023-08-13 |
Not clear |
O Galasso, M De Gori, S Cerbasi, F Familiari, P Recano, G Balato, G Gasparini, M Maricond. Tantalum monoblock cups in total hip arthroplasty: clinical results and outcome predictors. Journal of biological regulators and homeostatic agents. vol 32. issue 6 Suppl. 1. 2019-06-14. PMID:30644278. |
this study aims to report the minimum 2-year follow-up results of the tantalum monoblock cup in primary tha and to identify possible outcome predictors. |
2019-06-14 |
2023-08-13 |
human |
O Galasso, M De Gori, S Cerbasi, F Familiari, P Recano, G Balato, G Gasparini, M Maricond. Tantalum monoblock cups in total hip arthroplasty: clinical results and outcome predictors. Journal of biological regulators and homeostatic agents. vol 32. issue 6 Suppl. 1. 2019-06-14. PMID:30644278. |
eighty-eight porous tantalum monoblock acetabular cup in primary tha were reviewed. |
2019-06-14 |
2023-08-13 |
human |
Paul Arauz, Yun Peng, John MacAuliffe, Young-Min Kwo. In-vivo 3-Dimensional gait symmetry analysis in patients with bilateral total hip arthroplasty. Journal of biomechanics. vol 77. 2019-04-25. PMID:30037578. |
significant reduction in the magnitude of the acetabular cup adduction, stem adduction, and combine hip anteversion and adduction difference was observed in the bilateral tha group (p < 0.05). |
2019-04-25 |
2023-08-13 |
Not clear |
Anton Khlopas, Morad Chughtai, Randa K Elmallah, David Hip-Flores, Arthur L Malkani, Steven F Harwin, Michael A Mont, Michael D Rie. Novel Acetabular Cup for Revision THA Improves Hip Center of Rotation: A Radiographic Evaluation. Clinical orthopaedics and related research. vol 476. issue 2. 2019-03-14. PMID:29529662. |
novel acetabular cup for revision tha improves hip center of rotation: a radiographic evaluation. |
2019-03-14 |
2023-08-13 |
Not clear |
William S Murphy, Ho Hyun Yun, Brett Hayden, Jens H Kowal, Stephen B Murph. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA. Clinical orthopaedics and related research. vol 476. issue 2. 2019-03-14. PMID:29529664. |
the safe zone range for cup anteversion is narrower than for inclination in tha. |
2019-03-14 |
2023-08-13 |
Not clear |
William S Murphy, Ho Hyun Yun, Brett Hayden, Jens H Kowal, Stephen B Murph. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA. Clinical orthopaedics and related research. vol 476. issue 2. 2019-03-14. PMID:29529664. |
cup malposition is a common cause of impingement, limitation of rom, acceleration of bearing wear, liner fracture, and instability in tha. |
2019-03-14 |
2023-08-13 |
Not clear |
William S Murphy, Ho Hyun Yun, Brett Hayden, Jens H Kowal, Stephen B Murph. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA. Clinical orthopaedics and related research. vol 476. issue 2. 2019-03-14. PMID:29529664. |
the current study uses ct to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in tha. |
2019-03-14 |
2023-08-13 |
Not clear |
Hiroyuki Ogawa, Seiichirou Hasegawa, Sachiyuki Tsukada, Masaaki Matsubar. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty. The Journal of arthroplasty. vol 33. issue 6. 2019-03-05. PMID:29502961. |
this preliminary study was performed to assess the accuracy of the ar-hip system for acetabular cup placement during total hip arthroplasty (tha). |
2019-03-05 |
2023-08-13 |
Not clear |
James A Keene. CORR Insights®: Novel Acetabular Cup for Revision THA Improves Hip Center of Rotation: A Radiographic Evaluation. Clinical orthopaedics and related research. vol 476. issue 2. 2019-02-14. PMID:29529663. |
corr insights®: novel acetabular cup for revision tha improves hip center of rotation: a radiographic evaluation. |
2019-02-14 |
2023-08-13 |
Not clear |
Inari Laaksonen, Michelle Lorimer, Kirill Gromov, Antti Eskelinen, Ola Rolfson, Stephen E Graves, Henrik Malchau, Maziar Mohadde. Trabecular metal acetabular components in primary total hip arthroplasty. Acta orthopaedica. vol 89. issue 3. 2019-01-24. PMID:29400118. |
interpretation - risk of revision for any reason was higher for the tm cup than for other uncemented cups in primary tha. |
2019-01-24 |
2023-08-13 |
Not clear |
Mengcun Chen, Daniel J Gittings, Shuhua Yang, Xianzhe Li. Total Hip Arthroplasty for Crowe Type IV Developmental Dysplasia of the Hip Using a Titanium Mesh Cup and Subtrochanteric Femoral Osteotomy. The Iowa orthopaedic journal. vol 38. 2018-12-18. PMID:30104944. |
the purpose of this study is to describe the short term results of a retrospectively reviewed series of patients with crowe iv ddh treated with tha using a titanium mesh cup, cemented liner, and subtrochanteric femoral shortening osteotomy. |
2018-12-18 |
2023-08-13 |
Not clear |
Xinggui Song, Ming Ni, Heng Li, Xin Li, Xiang Li, Jun Fu, Jiying Che. Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach? Journal of orthopaedic surgery and research. vol 13. issue 1. 2018-10-08. PMID:29792206. |
the impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (tha) is not well studied. |
2018-10-08 |
2023-08-13 |
Not clear |