Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Loic Schneider, Frédéric Châtain, Gilles Estour, Sonia Ramos-Pascual, Luca Nover, Nicolas Boni. Total Hip Arthroplasty Using a Hemispherical Uncemented Dual-Mobility Cup Results in Satisfactory Clinical Outcomes and No Dislocations at 2 years. Arthroplasty today. vol 9. 2021-06-19. PMID:34136611. |
the authors performed total hip arthroplasty (tha) using a novel hemispherical dual-mobility (dm) acetabular cup without a protrusive cylindro-spherical rim, intended to reduce risks of iliopsoas impingement without requiring changes to conventional intraoperative positioning as with unipolar cups. |
2021-06-19 |
2023-08-13 |
Not clear |
Moritz M Innmann, Niall P McGoldrick, Akaash Ratra, Christian Merle, George Grammatopoulo. The accuracy in determining pelvic tilt from anteroposterior pelvic radiographs in patients awaiting hip arthroplasty. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2021-06-16. PMID:34081347. |
this may allow functional cup orientation after tha to be determined between different postures from an ap radiograph of the pelvis. the sfp angle has moderate accuracy in determining a patient's pelvic tilt; however, it can accurately determine a patient's change in pelvic tilt in different positions. |
2021-06-16 |
2023-08-13 |
Not clear |
Goulven Rochcongar, Matthieu Remazeilles, Emeline Bourroux, Julien Dunet, Valentin Chapus, Matthieu Feron, César Praz, Geoffrey Buia, Christophe Hule. Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial. Acta orthopaedica. vol 92. issue 2. 2021-06-14. PMID:33263447. |
we also assessed whether wear rates correlate with increasing cup inclination angles or cup sizes.patients and methods - this is a 5-year follow-up of our previously reported randomized controlled trial of 62 patients with 3 years' follow-up, who received tha with either an hxlpe/vite or a uhmwpe acetabular cup. |
2021-06-14 |
2023-08-13 |
Not clear |
Markus Weber, Franz Suess, Seth A Jerabek, Matthias Meyer, Joachim Grifka, Tobias Renkawitz, Sebastian Dendorfe. Kinematic pelvic tilt during gait alters functional cup position in total hip arthroplasty. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2021-06-14. PMID:34057752. |
static pelvic tilt impacts functional cup position in total hip arthroplasty (tha). |
2021-06-14 |
2023-08-13 |
Not clear |
Markus Weber, Franz Suess, Seth A Jerabek, Matthias Meyer, Joachim Grifka, Tobias Renkawitz, Sebastian Dendorfe. Kinematic pelvic tilt during gait alters functional cup position in total hip arthroplasty. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2021-06-14. PMID:34057752. |
kinematic pelvic changes highly impact cup anteversion in tha. |
2021-06-14 |
2023-08-13 |
Not clear |
Ragna C Jonker, Loes W A H van Beers, Bart C H van der Wal, H Charles Vogely, Sebastien Parratte, René M Castelein, Rudolf W Poolma. Can dual mobility cups prevent dislocation without increasing revision rates in primary total hip arthroplasty? A systematic review. Orthopaedics & traumatology, surgery & research : OTSR. vol 106. issue 3. 2021-06-10. PMID:32278733. |
therefore, we did a systematic review to investigate whether there is a difference in the rate of dislocations and revisions after primary tha with a dm cup or a up cup. |
2021-06-10 |
2023-08-13 |
Not clear |
Anders Elneff Graversen, Claus Varnu. [Dislocated dual mobility liner after hip dislocation]. Ugeskrift for laeger. vol 182. issue 37. 2021-06-10. PMID:33000722. |
intraprosthetic dislocation (ipd) during closed reduction in primary total hip arthroplasty (tha) with a dual mobility cup (dmc) is a well-known, but rare complication. |
2021-06-10 |
2023-08-13 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Hiroki Wakabayashi, Akihiro Sud. Accuracy of acetabular cup insertion in an anterolateral supine approach using an accelerometer-based portable navigation system. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. vol 24. issue 1. 2021-06-07. PMID:32880017. |
the purpose of this study was to determine the accuracy of acetabular cup insertion during total hip arthroplasty (tha) in a supine position using an accelerometer-based portable navigation system. |
2021-06-07 |
2023-08-13 |
Not clear |
Tingxian Ling, Zichuan Ding, Mingcheng Yuan, Kai Zhou, Zongke Zho. The influence of sagittal pelvic malrotation on transverse acetabular ligament guided cup orientation: a retrospective cohort study. BMC musculoskeletal disorders. vol 22. issue 1. 2021-06-01. PMID:34049510. |
the aim of this study is to analyze how pelvic malrotation influence transverse acetabular ligament (tal) guided cup orientation and investigate whether pelvic malrotation produce different clinical outcomes after tha. |
2021-06-01 |
2023-08-13 |
Not clear |
Jacob Shapira, Shawn Annin, Philip J Rosinsky, David R Maldonado, Ajay C Lall, Benjamin G Dom. Total hip arthroplasty after pelvic osteotomy for acetabular dysplasia: A systematic review. Journal of orthopaedics. vol 25. 2021-05-23. PMID:34017159. |
po may entail challenges on a subsequent tha, illustrated by higher intraoperative blood loss, lower consistency in cup positioning and compromised patients reported outcomes. |
2021-05-23 |
2023-08-13 |
Not clear |
Byung-Woo Min, Ki-Cheor Bae, Chul-Hyun Cho, Eun-Suck Son, Kyung-Jae Lee, Si-Wook Le. Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study. Indian journal of orthopaedics. vol 54. issue Suppl 2. 2021-05-21. PMID:33194097. |
outcomes of tha after acetabular fracture are generally less favorable than those of the nontraumatic arthritis due to a higher rate of cup loosening and osteolysis. |
2021-05-21 |
2023-08-13 |
Not clear |
Kuei-Lin Yeh, Tai-Yin Wu, Hsuan-Hsiao Ma, Sheng-Mou Hou, Chen-Kun Lia. Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty. BMC musculoskeletal disorders. vol 21. issue 1. 2021-05-14. PMID:33032565. |
several cup anteversion measurements for post-operative total hip arthroplasty (tha) surgery have been described. |
2021-05-14 |
2023-08-13 |
Not clear |
Georgina Waters, Peter D'Alessandro, Piers Yate. Functional navigation in hip resurfacing. ANZ journal of surgery. vol 91. issue 1-2. 2021-05-14. PMID:33164345. |
historically lewinnek's safe zone has been the goal for optimal tha cup positioning; however, research indicates that one generic safe zone is not ideal. |
2021-05-14 |
2023-08-13 |
Not clear |
Masanori Okamoto, Masashi Kawasaki, Toshiaki Okura, Taisuke Seki, Shiro Imagam. Effects of body mass index and range of motion on intraoperative change in pelvic tilt during total hip arthroplasty using the direct anterior approach. BMC musculoskeletal disorders. vol 22. issue 1. 2021-05-14. PMID:33653316. |
intraoperative pelvic tilt changes that occurs during total hip arthroplasty (tha) in the supine position affects cup placement and sometimes causes malalignment. |
2021-05-14 |
2023-08-13 |
Not clear |
Takaki Miyagawa, Kazu Matsumoto, Shingo Komura, Haruhiko Akiyam. Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis. BMC musculoskeletal disorders. vol 22. issue 1. 2021-05-14. PMID:33771146. |
we investigated the mid-term clinical and radiological results of total hip arthroplasty (tha) using a three-dimensional (3d) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (fe) analysis. |
2021-05-14 |
2023-08-13 |
Not clear |
Moritz Kaiser, Tobias Renkawitz, Achim Benditz, Matthias König, Max Thieme, Markus Webe. Pelvic tilt impacts cup orientation on CT: how accurate is the gold standard? Acta radiologica (Stockholm, Sweden : 1987). 2021-05-13. PMID:33982602. |
computed tomography (ct) is the gold standard for the accurate measurement of cup inclination and anteversion in total hip arthroplasty (tha). |
2021-05-13 |
2023-08-13 |
Not clear |
Babar Kayani, Sujith Konan, Sumon S Huq, Mazin S Ibrahim, Atif Ayuob, Fares S Hadda. The learning curve of robotic-arm assisted acetabular cup positioning during total hip arthroplasty. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 31. issue 3. 2021-05-12. PMID:31838874. |
the objective of this study was to assess the surgical team's learning curve for robotic-arm assisted acetabular cup positioning during tha. |
2021-05-12 |
2023-08-13 |
Not clear |
Karl-Heinz Widme. The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components. Clinical orthopaedics and related research. vol 478. issue 8. 2021-05-11. PMID:32732575. |
lewinnek's recommendation for orienting the cup in tha is criticized because it involves a static assessment of the safe zone and because it does not consider stem geometry. |
2021-05-11 |
2023-08-13 |
Not clear |
Shunsaku Nishihara, Kenji Hayashid. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Archives of orthopaedic and trauma surgery. 2021-04-30. PMID:33929597. |
in total hip arthroplasty (tha), improper cup orientation can result in dislocation, early excessive polyethylene wear, and pain following tha. |
2021-04-30 |
2023-08-13 |
Not clear |
Shunsaku Nishihara, Kenji Hayashid. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Archives of orthopaedic and trauma surgery. 2021-04-30. PMID:33929597. |
the supine position during tha provides a more reproducible functional pelvic position than the lateral decubitus position and may allow freehand cup placement as reliable as that obtained by computer navigation. |
2021-04-30 |
2023-08-13 |
Not clear |