All Relations between ct and thoracic

Publication Sentence Publish Date Extraction Date Species
Gabriella Yongue, Alexander Hotouras, Jamie Murphy, Hasan Mukhtar, Chetan Bhan, Christopher L Cha. The diagnostic yield of preoperative staging computed tomography of the thorax in colorectal cancer patients without hepatic metastases. European journal of gastroenterology & hepatology. vol 27. issue 4. 2016-01-05. PMID:25874523. national uk guidelines recommend preoperative computed tomography (ct) examination of the chest for all patients with colorectal cancer (crc) as identification of thoracic metastatic disease may influence treatment plans. 2016-01-05 2023-08-13 Not clear
Divya Narayanan, Jiamin Liu, Lauren Kim, Kevin W Chang, Le Lu, Jianhua Yao, Evrim B Turkbey, Ronald M Summer. Automated segmentation of the thyroid gland on thoracic CT scans by multiatlas label fusion and random forest classification. Journal of medical imaging (Bellingham, Wash.). vol 2. issue 4. 2016-01-05. PMID:26730397. automated segmentation of the thyroid gland on thoracic ct scans by multiatlas label fusion and random forest classification. 2016-01-05 2023-08-13 Not clear
Mihir Desai, Babbin John, Gillian Evans, Ben Edd. Prostate cancer: beware of disseminated intravascular coagulation. BMJ case reports. vol 2015. 2015-12-31. PMID:25819815. subsequent investigations revealed a prostate-specific antigen (psa) >1000 µg/l, and staging ct showed multiple sclerotic metastatic lesions affecting the thoracic and lumbar vertebra, as well as infiltration into his left femur. 2015-12-31 2023-08-13 Not clear
Daniela Arriagada S, Alejandro Donoso F, Pablo Cruces R, Jaime Verdugo . [Nephrobronchial fístula in pediatric patient: case report]. Archivos argentinos de pediatria. vol 112. issue 4. 2015-12-28. PMID:24955916. thoracic and abdominal ct scan was performed corroborating transdiaphragmatic fistula. 2015-12-28 2023-08-13 Not clear
Georg Homann, Deedar F Mustafa, Hendrik Ditt, Werner Spengler, Hans-Georg Kopp, Konstantin Nikolaou, Marius Horge. Improved detection of bone metastases from lung cancer in the thoracic cage using 5- and 1-mm axial images versus a new CT software generating rib unfolding images: comparison with standard ¹⁸F-FDG-PET/CT. Academic radiology. vol 22. issue 4. 2015-12-28. PMID:25586709. improved detection of bone metastases from lung cancer in the thoracic cage using 5- and 1-mm axial images versus a new ct software generating rib unfolding images: comparison with standard ¹⁸f-fdg-pet/ct. 2015-12-28 2023-08-13 Not clear
René Werner, Alexander Schmidt-Richberg, Heinz Handels, Jan Ehrhard. Estimation of lung motion fields in 4D CT data by variational non-linear intensity-based registration: A comparison and evaluation study. Physics in medicine and biology. vol 59. issue 15. 2015-12-24. PMID:25017631. in this work, we present a comprehensive comparison and evaluation study of non-linear registration variants applied to the task of lung motion estimation in thoracic 4d ct data. 2015-12-24 2023-08-13 Not clear
René Schmid. Reviewer's comment concerning "CT morphometry of adult thoracic intervertebral discs" by Justin G. R. Fletcher et al. (Eur Spine J, 2015; doi:10.1007/s00586-015-3925-y). European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. vol 24. issue 10. 2015-12-24. PMID:25995114. reviewer's comment concerning "ct morphometry of adult thoracic intervertebral discs" by justin g. r. fletcher et al. 2015-12-24 2023-08-13 Not clear
Yoon Kyung Kim, Yon Mi Sung, Kyung Hoon Hwang, Eun Kyung Cho, Hye-Young Cho. Pseudopathologic vertebral body enhancement in the presence of superior vena cava obstruction on computed tomography. The spine journal : official journal of the North American Spine Society. vol 15. issue 6. 2015-12-23. PMID:24113676. during contrast-enhanced thoracic computed tomography (ct), contrast material may reflux into the collaterals such as paravertebral venous plexus. 2015-12-23 2023-08-12 Not clear
Alexandra R Cunliffe, Samuel G Armato, Christopher Straus, Renuka Malik, Hania A Al-Halla. Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy. Physics in medicine and biology. vol 59. issue 18. 2015-12-18. PMID:25157625. lung texture in serial thoracic ct scans: correlation with radiologist-defined severity of acute changes following radiation therapy. 2015-12-18 2023-08-13 Not clear
Marco Giambuzzi, Sara Seitun, Antonio Salsano, Giancarlo Passerone, Carlo Ferro, Francesco Santin. Nongated vs electrocardiography-gated CT imaging of blunt aortic root rupture in a trauma patient. Journal of cardiovascular computed tomography. vol 9. issue 2. 2015-12-16. PMID:25499201. an 18-year-old male, involved in a car accident, underwent a non-gated contrast enhanced ct with apparently no evidence of significant abnormalities of the thoracic aorta. 2015-12-16 2023-08-13 Not clear
May San Mak, Ching Ching Ong, Edgar Lik Wui Tay, Lynette Li San Te. Clinics in diagnostic imaging (155). Incidental PDA with secondary pulmonary arterial hypertension. Singapore medical journal. vol 55. issue 9. 2015-12-15. PMID:25273929. ct clearly demonstrated a vascular structure connecting the descending thoracic aorta to the roof of the proximal left pulmonary artery, consistent with a pda. 2015-12-15 2023-08-13 Not clear
D Ait Ali Yahia, A Bouvier, C Nedelcu, M Urdulashvili, F Thouveny, C Ridereau, J Y Tanguy, J Picquet, C Aube, S Willoteau. Imaging of thoracic aortic injury. Diagnostic and interventional imaging. vol 96. issue 1. 2015-12-15. PMID:25540927. the main ct signs of rupture or disruption of the thoracic aorta are periaortic hematoma, intimal flap, pseudo-aneurysm and contrast agent extravasation. 2015-12-15 2023-08-13 Not clear
Chun-Chien Shieh, John Kipritidis, Ricky T O'Brien, Benjamin J Cooper, Zdenka Kuncic, Paul J Keal. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR). Physics in medicine and biology. vol 60. issue 2. 2015-12-15. PMID:25565244. improving thoracic four-dimensional cone-beam ct reconstruction with anatomical-adaptive image regularization (aair). 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. radiation dose reduction in thoracic and abdomen-pelvic ct using tube current modulation: a phantom study. 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. this phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic ct scans with and without use of tube current modulation (tcm). 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. when compared to protocols without tcm, the ed and ssde were reduced significantly with use of tcm for both the thoracic and abdomen-pelvic ct. with use of tcm, the ed was 6.50 ± 0.29 msv for thoracic and 6.01 ± 0.20 msv for the abdomen-pelvic ct protocols. 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. however without use of tcm, the ed was 20.07 ± 0.24 msv and 17.30 ± 0.41 msv for the thoracic and abdomen-pelvic ct protocols, respectively. 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. the corresponding ssde was 10.18 ± 0.48 mgy and 11.96 ± 0.27 mgy for the thoracic and abdomen-pelvic ct protocols with tcm, and 31.56 ± 0.43 mgy and 33.23 ± 0.05 mgy for thoracic and abdomen-pelvic ct protocols without tcm, respectively. 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. the highest absorbed dose was measured at the breast with 8.58 ± 0.12 mgy in the tcm protocols and 51.52 ± 14.72 mgy in the protocols without tcm during thoracic ct. 2015-12-15 2023-08-13 Not clear
Akmal Sabarudin, Zakira Mustafa, Khadijah Mohd Nassir, Hamzaini Abdul Hamid, Zhonghua Su. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study. Journal of applied clinical medical physics. vol 16. issue 1. 2015-12-15. PMID:25679153. in conclusion, the tcm technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic ct. 2015-12-15 2023-08-13 Not clear