All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Simon K Goodall, Pejman Rowshanfarzad, Martin A Eber. Correction factors for commissioning and patient specific quality assurance of stereotactic fields in a Monte Carlo based treatment planning system : TPS correction factors. Physical and engineering sciences in medicine. 2023-04-06. PMID:37022612. correction factors for commissioning and patient specific quality assurance of stereotactic fields in a monte carlo based treatment planning system : tps correction factors. 2023-04-06 2023-08-14 Not clear
Simon K Goodall, Pejman Rowshanfarzad, Martin A Eber. Correction factors for commissioning and patient specific quality assurance of stereotactic fields in a Monte Carlo based treatment planning system : TPS correction factors. Physical and engineering sciences in medicine. 2023-04-06. PMID:37022612. accurate and considered measurement of linear accelerator dose must be compared to precise and accurate calculation by the treatment planning system (tps). 2023-04-06 2023-08-14 Not clear
Elahe Sorooshfard, Marziyeh Tahmasbi, Nahid Chegeni, Mohammad Javad Tahmasebi Birgan. Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study. Journal of cancer research and therapeutics. vol 19. issue 2. 2023-04-03. PMID:37006077. this study evaluated the effects of scan parameters (kilovoltage peak or kvp, milli-ampere-second or mas reconstruction kernels and algorithms, reconstruction field of view, and slice thickness) on image quality, hus, and the calculated dose in the treatment planning system (tps). 2023-04-03 2023-08-14 Not clear
Odran Pivot, Patrick Pittet, Rolf Clackdoyle, Laurent Desbat, Simon Ri. A tomographic reconstruction algorithm for cross-sectional imaging of IMRT beams from six projections. Physics in medicine and biology. 2023-03-30. PMID:36996850. a radiochromic film was used to acquire a reference measurement of a first dose distribution in the slab phantom at the same source-to-detector distance and the treatment planning system (tps) provided the reference for another dose distribution. 2023-03-30 2023-08-14 Not clear
Yu-Shiang Huang, Jinn-Jer Peir, Chuan-Jen Wu, Mei-Ya Wang, Yi-Wei Chen, Jia-Cheng Lee, Fong-In Cho. NeuTHOR Station-A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR. Life (Basel, Switzerland). vol 13. issue 3. 2023-03-29. PMID:36983956. (1) background: a well-established boron neutron capture therapy (bnct) facility includes many essential systems, which are the epithermal neutron beam system, on-line monitoring system (oms), qa/qc (quality assurance or quality control) system, boron concentration (bc) measurement system, and treatment planning system (tps). 2023-03-29 2023-08-14 Not clear
E Patterson, P Stokes, D Cutajar, A Rosenfeld, J Baines, P Metcalfe, M Power. High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac. Physical and engineering sciences in medicine. 2023-03-29. PMID:36988905. simulations with geant4 and the monaco treatment planning system (tps), and ebt-3 film measurements, were also performed for comparison. 2023-03-29 2023-08-14 Not clear
Hans Lynggaard Riis, Rasmus Lübeck Christiansen, Nina Tilly, David Till. Dosimetric validation of the couch and coil model for high-field MR-linac treatment planning. Zeitschrift fur medizinische Physik. 2023-03-29. PMID:36990882. this work aimed to compare the attenuation of two ppss located at two different mr-linac sites through measurements and calculations in the treatment planning system (tps). 2023-03-29 2023-08-14 Not clear
Mohammed Lahlabou, Rachid Khelif. Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film. Journal of medical physics. vol 47. issue 4. 2023-03-13. PMID:36908487. most brachytherapy treatment planning system (tps) commissioning requires data input based on the american association of physicists in medicine task group-43 formalism. 2023-03-13 2023-08-14 Not clear
Suah Yu, So Hyun Ahn, Sang Hyoun Choi, Woo Sang Ahn, In-Hye Jun. Clinical Application of a Customized 3D-Printed Bolus in Radiation Therapy for Distal Extremities. Life (Basel, Switzerland). vol 13. issue 2. 2023-02-25. PMID:36836718. the clinical feasibility of the boluses was evaluated by measuring the in vivo skin dose at the tumor site with optically stimulated luminescence detectors (oslds) and comparing the results with the prescribed and calculated doses from the eclipse treatment planning system (tps). 2023-02-25 2023-08-14 Not clear
Louise Murray, Christopher Thompson, Christopher Pagett, John Lilley, Bashar Al-Qaiseh, Stina Svensson, Kjell Eriksson, Michael Nix, Michael Aldred, Lynn Aspin, Stephen Gregory, Ane Appel. Treatment plan optimisation for reirradiation. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2023-02-22. PMID:36813170. the strider (support tool for re-irradiation decisions guided by radiobiology) project aims to create a clinically viable re-irradiation planning pathway within a commercial treatment planning system (tps). 2023-02-22 2023-08-14 Not clear
Poonam Yadav, Colleen M DesRosiers, Raj K Mitra, Shiv P Srivastava, Indra J Da. Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study. Journal of clinical medicine. vol 12. issue 3. 2023-02-11. PMID:36769553. dose-calculation algorithms are critical for radiation treatment outcomes that vary among treatment planning systems (tps). 2023-02-11 2023-08-14 human
Thomas Tessonnier, Swantje Ecker, Judith Besuglow, Jakob Naumann, Stewart Mein, Friderike K Longarino, Malte Ellerbrock, Benjamin Ackermann, Marcus Winter, Stephan Brons, Abdallah Qubala, Thomas Haberer, Jürgen Debus, Oliver Jäkel, Andrea Mairan. Commissioning of helium ion therapy and the first patient treatment with active beam delivery. International journal of radiation oncology, biology, physics. 2023-01-21. PMID:36681200. this work presents the commissioning of the first clinical treatment planning system (tps) for helium ion therapy with active beam delivery to prepare the first patients' treatment at the institution-xxx methods: : through collaboration between raysearch laboratories and institution-xxx, absorbed and relative biological effectiveness (rbe)-weighted calculation methods were integrated for helium ion beam therapy with raster-scanned delivery in the tps raystation. 2023-01-21 2023-08-14 Not clear
Kai Jiang, Michael MacFarlane, Sina Mossahebi, Mark J Zakhar. Evaluation of treatment planning system accuracy in estimating the stopping-power ratio of immobilization devices for proton therapy. Journal of applied clinical medical physics. 2023-01-03. PMID:36593751. to assess treatment planning system (tps) accuracy in estimating the stopping-power ratio (spr) of immobilization devices commonly used in proton therapy and to evaluate the dosimetric effect of spr estimation error for a set of clinical treatment plans. 2023-01-03 2023-08-14 Not clear
Suman Kumar Putha, Dilson Lobo, Holla Raghvendra, Challapalli Srinvias, Sourjya Banerjee, M S Athiyamaan, Johan Sunny K, Abhishek Krishn. Evaluation of Inhomogeneity Correction Performed by Radiotherapy Treatment Planning System. Asian Pacific journal of cancer prevention : APJCP. vol 23. issue 12. 2022-12-29. PMID:36579997. aim of this study is to evaluate the efficacy of inhomogeneity corrections calculated by radiotherapy treatment planning system (tps) using various densities of materials. 2022-12-29 2023-08-14 Not clear
Fabian Kugel, Jörg Wulff, Christian Bäumer, Martin Janson, Jana Kretschmer, Leonie Brodbek, Carina Behrends, Nico Verbeek, Hui Khee Looe, Björn Poppe, Beate Timmerman. Validating a double Gaussian source model for small proton fields in a commercial Monte-Carlo dose calculation engine. Zeitschrift fur medizinische Physik. 2022-12-28. PMID:36577626. although small in magnitude, this spray may affect dose distributions in pencil beam scanning mode e.g., in the calculation of the small field output, if not modelled properly in a treatment planning system (tps). 2022-12-28 2023-08-14 Not clear
Ezgi Oymak, Recep Bozca, Ozan Cem Guler, Cem Ona. Contralateral breast radiation doses in breast cancer patients treated with helical tomotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2022-12-26. PMID:36572598. we aimed to evaluate contralateral breast doses calculated with a treatment planning system (tps) and verified with metal oxide semiconductor field effect transistor (mosfet) detectors in patients with early-stage breast cancer (bc) who received helical tomotherapy (ht) after breast-conserving surgery. 2022-12-26 2023-08-14 Not clear
Ezgi Oymak, Recep Bozca, Ozan Cem Guler, Cem Ona. Contralateral breast radiation doses in breast cancer patients treated with helical tomotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2022-12-26. PMID:36572598. tps and mosfet doses were compared in the entire cohort as well as by tumor location (inner vs outer quadrant) and planning target volume of the breast (<1200 cc vs ≥1200 cc). 2022-12-26 2023-08-14 Not clear
Mansure Schafasand, Andreas Franz Resch, Piero Fossati, Markus Stock, Joanna Gora, Dietmar Georg, Erik Traneus, Lars Glimelius, Antonio Carlin. Technical Note: In-silico benchmarking of the linear energy transfer based functionalities for carbon ion beams in a commercial treatment planning system. Medical physics. 2022-12-19. PMID:36534738. the increasing number of studies dealing with linear energy transfer (let)-based evaluation and optimization in the field of carbon ion radiotherapy indicates the rising demand for let implementation in commercial treatment planning systems (tps). 2022-12-19 2023-08-14 Not clear
Weiwei Wang, Ping Li, Kambiz Shahnazi, Xiaodong Wu, Jingfang Zha. Calculating dose-averaged linear energy transfer in an analytical treatment planning system for carbon-ion radiotherapy. Journal of applied clinical medical physics. 2022-12-17. PMID:36527366. however, the ability to calculate the letd in commercially available treatment planning systems (tps) is lacking. 2022-12-17 2023-08-14 Not clear
Emel Calugaru, Zachary Whiting, Brandon Delacruz, Daniel Ma, Barbara Garcia, Anuj Goenka, Jenghwa Chan. Direct dosimetric comparison of linear accelerator vs. Gamma Knife fractionated stereotactic radiotherapy (fSRT) of large brain tumors. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2022-12-12. PMID:36503990. eighteen patients with clinical target volumes (ctvs) larger than 9.5 cc were selected to generate comparative plans for the prescription dose of 9 gy × 3 fractions, utilizing the eclipse (varian, palo alto, us) vs leksell gammaplan (lgp) (elekta, stockholm, sweden) treatment planning systems (tps). 2022-12-12 2023-08-14 Not clear