All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
Kent A Gifford, John L Horton, Edward F Jackson, Theodore R Steger, Malcolm P Heard, Firas Mourtada, Ann A Lawyer, Geoffrey S Ibbot. Comparison of Monte Carlo calculations around a Fletcher Suit Delclos ovoid with radiochromic film and normoxic polymer gel dosimetry. Medical physics. vol 32. issue 7. 2005-10-05. PMID:16121584. many treatment planning systems (tps) do not include the shields and other ovoid structures in the dose calculation. 2005-10-05 2023-08-12 Not clear
O Jäkel, M Krämer, D Schulz-Ertner, P Heeg, C P Karger, B Didinger, A Nikoghosyan, J Debu. Treatment planning for carbon ion radiotherapy in Germany: review of clinical trials and treatment planning studies. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 73 Suppl 2. 2005-07-12. PMID:15971317. the introduction of an active beam shaping system for carbon ions has considerable impact on the design of the treatment planning system (tps). 2005-07-12 2023-08-12 Not clear
O Jäkel, M Krämer, D Schulz-Ertner, P Heeg, C P Karger, B Didinger, A Nikoghosyan, J Debu. Treatment planning for carbon ion radiotherapy in Germany: review of clinical trials and treatment planning studies. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 73 Suppl 2. 2005-07-12. PMID:15971317. the tps used in clinical routine with carbon ions is described and its use in treatment planning studies are outlined. 2005-07-12 2023-08-12 Not clear
S Steciw, B Warkentin, S Rathee, B G Fallon. Three-dimensional IMRT verification with a flat-panel EPID. Medical physics. vol 32. issue 2. 2005-06-28. PMID:15789607. in our new 3d verification technique, 2d fluence modulation profiles for each imrt field in a treatment are used as input to a treatment planning system (tps), which then generates 3d doses. 2005-06-28 2023-08-12 Not clear
G G Daquino, N Cerullo, M Mazzini, R L Moss, L Muz. Experimental and computational validation of BDTPS using a heterogeneous boron phantom. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. vol 61. issue 5. 2005-06-13. PMID:15308164. the idea to couple the treatment planning system (tps) to the information on the real boron distribution in the patient acquired by positron emission tomography (pet) is the main added value of the new methodology set-up at dimnp (dipartimento di ingegneria meccanica, nucleare e della produzione) of university of pisa, in collaboration with the jrc (joint research centre) at petten (nl). 2005-06-13 2023-08-12 Not clear
G G Daquino, N Cerullo, M Mazzini, R L Moss, L Muz. Experimental and computational validation of BDTPS using a heterogeneous boron phantom. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. vol 61. issue 5. 2005-06-13. PMID:15308164. this methodology has been implemented in a new tps, called boron distribution treatment planning system (bdtps), which takes into account the actual boron distribution in the patient's organ, as opposed to other tpss used in bnct that assume an ideal uniform boron distribution. 2005-06-13 2023-08-12 Not clear
M Fragoso, P A Love, F Verhaegen, C Nalder, A M Bidmead, M Leach, S Web. The dose distribution of low dose rate Cs-137 in intracavitary brachytherapy: comparison of Monte Carlo simulation, treatment planning calculation and polymer gel measurement. Physics in medicine and biology. vol 49. issue 24. 2005-05-31. PMID:15724536. the results obtained were compared with a commercial treatment planning system (tps). 2005-05-31 2023-08-12 Not clear
Alanah M Bergman, Karl Otto, Cheryl Duzenl. The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy. Medical physics. vol 31. issue 12. 2005-04-21. PMID:15651610. improvements in dose calculation accuracy have been reported when the treatment planning system (tps) is recommissioned using high-resolution measurement data as input. 2005-04-21 2023-08-12 Not clear
Alanah M Bergman, Karl Otto, Cheryl Duzenl. The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy. Medical physics. vol 31. issue 12. 2005-04-21. PMID:15651610. this study proposes to improve the dose calculation accuracy for imrt planning by modifying clinical dose kernel shapes already present in the tps, thus avoiding the need to reacquire higher resolution commissioning data. 2005-04-21 2023-08-12 Not clear
Ans Swinnen, Jan Verstraete, Dominique Pierre Huysken. Feasibility study of entrance in vivo dose measurements with mailed thermoluminescence detectors. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 73. issue 1. 2005-02-25. PMID:15465151. the aim of this work is to set-up mailed entrance in vivo dosimetry by means of thermoluminescence dosimeters (tlds) in the form of lif powder in order to assess the overall accuracy of patient treatment delivery by comparing the doses delivered to patients with the doses calculated by the treatment planning system (tps) in different institutions. 2005-02-25 2023-08-12 Not clear
G Anagnostopoulos, D Baltas, E Pantelis, P Papagiannis, L Sakellio. The effect of patient inhomogeneities in oesophageal 192Ir HDR brachytherapy: a Monte Carlo and analytical dosimetry study. Physics in medicine and biology. vol 49. issue 12. 2005-01-04. PMID:15272681. analytical calculations in this work are in good agreement with corresponding monte carlo results within the bone inhomogeneities of spinal cord and sternum bone but, like treatment planning system calculations, the model fails to predict the dose distribution in the proximal lung surface as well as within the lungs just as the tps does, due to its inherent limitation in treating lateral scatter and backscatter radiation. 2005-01-04 2023-08-12 Not clear
C B Kwok, G Lam, S El-Saye. Suitability of using multileaf collimator (MLC) for photon field matching. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 29. issue 3. 2004-12-16. PMID:15324915. the study was conducted using film-based dosimetry for measurements and a theraplan plus (version 3.8) treatment planning system (tps) for planning comparisons and additional field matching investigations. 2004-12-16 2023-08-12 Not clear
T Knöös, C Ceberg, L Weber, P Nilsso. The dosimetric verification of a pencil beam based treatment planning system. Physics in medicine and biology. vol 39. issue 10. 2004-12-15. PMID:15551534. a new three-dimensional treatment planning system (tps) based on convolution/superposition algorithms (tms-radix from helax ab, uppsala, sweden) was recently installed at the university hospital in lund. 2004-12-15 2023-08-12 Not clear
T Knöös, C Ceberg, L Weber, P Nilsso. The dosimetric verification of a pencil beam based treatment planning system. Physics in medicine and biology. vol 39. issue 10. 2004-12-15. PMID:15551534. the results indicate clearly that the model is well suited for clinical three-dimensional dose planning and that the tps handles data as expected. 2004-12-15 2023-08-12 Not clear
G Cranmer-Sargison, W A Beckham, I A Popesc. Modelling an extreme water-lung interface using a single pencil beam algorithm and the Monte Carlo method. Physics in medicine and biology. vol 49. issue 8. 2004-11-19. PMID:15152692. at nominal x-ray energies of 6 and 18 mv, dose distributions were modelled for field sizes of 10 x 10 cm(2) and 4 x 4 cm(2) using the cadplan 6.0 commercial treatment planning system (tps) and the beamnrc-dosxyznrc monte carlo package. 2004-11-19 2023-08-12 Not clear
Hansjörg Wertz, Oliver Jäke. Influence of iodine contrast agent on the range of ion beams for radiotherapy. Medical physics. vol 31. issue 4. 2004-11-02. PMID:15124994. the measured range shift in ca is much smaller than calculated by the treatment planning system (tps). 2004-11-02 2023-08-12 Not clear
Sung-Joon Ye, Ivan A Brezovich, Sui Shen, Siyong Ki. Dose errors due to inhomogeneities in balloon catheter brachytherapy for breast cancer. International journal of radiation oncology, biology, physics. vol 60. issue 2. 2004-11-02. PMID:15380605. to evaluate dose errors in balloon catheter brachytherapy of breast cancer due to inhomogeneities, such as iodine-containing radiographic contrast medium in the balloon, the lack of scattering medium, and the low density of lung that are not considered by commercial treatment planning systems (tps). 2004-11-02 2023-08-12 Not clear
S M J J G Nijsten, A W H Minken, P Lambin, I A D Bruinvi. Verification of treatment parameter transfer by means of electronic portal dosimetry. Medical physics. vol 31. issue 2. 2004-09-30. PMID:15000620. by combining geometric and dosimetric information, the data transfer between treatment planning system (tps) and linear accelerator can be verified which in particular is important when this transfer is not carried out electronically. 2004-09-30 2023-08-12 Not clear
Panagiotis Sandilos, Angelos Angelopoulos, Panagiotis Baras, Konstantinos Dardoufas, Pantelis Karaiskos, Panagiotis Kipouros, Marek Kozicki, Janusz M Rosiak, Loukas Sakelliou, Ioannis Seimenis, Lampros Vlaho. Dose verification in clinical IMRT prostate incidents. International journal of radiation oncology, biology, physics. vol 59. issue 5. 2004-08-30. PMID:15275742. treatment planning system (tps) calculations were evaluated against dose measurements. 2004-08-30 2023-08-12 Not clear
Marta Bucciolini, Fabrizio Banci Buonamici, Marta Casat. Verification of IMRT fields by film dosimetry. Medical physics. vol 31. issue 1. 2004-08-24. PMID:14761032. this ranges from the calculation of the optimal distribution of fluence by the treatment planning system (tps), to the dose delivery through a multilamellar collimator (mlc), with several segments per beam in the step and shoot approach. 2004-08-24 2023-08-12 Not clear