All Relations between planning and mr

Publication Sentence Publish Date Extraction Date Species
Wajana Thaweerat, Pittaya Dankulcha. Case report: Stereotactic MR-guided adaptive radiotherapy for inoperable urothelial carcinoma at the renal pelvis. Frontiers in oncology. vol 13. 2024-01-23. PMID:38260853. daily adaptive planning from mr images obtained before treatment could improve the target dose and minimize the organ at risk dose. 2024-01-23 2024-01-25 Not clear
Min Liu, Bin Tang, Lucia Clara Orlandini, Jie Li, Xianliang Wang, Qian Peng, David Thwaite. Potential dosimetric error in the adaptive workflow of a 1.5 T MR-Linac from patient movement relative to immobilisation systems. Physical and engineering sciences in medicine. 2024-01-16. PMID:38227140. this study highlights the dosimetric effect of using this in such workflows when there are relative patient-ppd displacements, as these are not visualized on mr imaging and the treatment planning system assumes the patient is fixed relative to the ppd. 2024-01-16 2024-01-18 Not clear
Naz Doganci, Sélim Yahia Coll, Emilie Marti, Radek Pta. Anatomical predictors of mental rotation with bodily and non-bodily stimuli: A lesion-symptom study. Neuropsychologia. 2023-12-22. PMID:38135209. these commonalities imply that mr may depend on brain regions crucial for the planning and execution of motor programs. 2023-12-22 2023-12-25 human
Naz Doganci, Sélim Yahia Coll, Emilie Marti, Radek Pta. Anatomical predictors of mental rotation with bodily and non-bodily stimuli: A lesion-symptom study. Neuropsychologia. 2023-12-22. PMID:38135209. these findings support the causal involvement of the left hemisphere in mr and underscore the existence of a common anatomical substrate in brain regions pertinent to motor planning and execution. 2023-12-22 2023-12-25 human
Yucel Akdeniz, Burcin Ispi. Whole-brain radiotherapy with hippocampus sparing and simultaneous integrated boost to metastases: A plan quality comparison study between Ethos, HyperArc, VMAT and Tomotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2023-12-15. PMID:38101995. planning ct scans with 2 mm slice thickness and mr imaging were used for contouring and dose prescription. 2023-12-15 2023-12-18 Not clear
Skylar S Gay, Carlos E Cardenas, Callistus Nguyen, Tucker J Netherton, Cenji Yu, Yao Zhao, Stephen Skett, Tina Patel, Delali Adjogatse, Teresa Guerrero Urbano, Komeela Naidoo, Beth M Beadle, Jinzhong Yang, Ajay Aggarwal, Laurence E Cour. Fully-automated, CT-only GTV contouring for palliative head and neck radiotherapy. Scientific reports. vol 13. issue 1. 2023-12-08. PMID:38066074. planning for palliative radiotherapy is performed without the advantage of mr or pet imaging in many clinics. 2023-12-08 2023-12-17 Not clear
Kim S Zimmermann, Martin Aman, Leila Harhaus, Arne H Boecke. Improving outcomes in traumatic peripheral nerve injuries to the upper extremity. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2023-10-20. PMID:37864051. rapid and accurate diagnosis of the lesion by electroneurography, neurosonography, or even mr neurography is important for treatment planning. 2023-10-20 2023-11-08 Not clear
Elisa Colombo, Bart Lutters, Tessa Kos, Tristan van Doormaa. Application of virtual and mixed reality for 3D visualization in intracranial aneurysm surgery planning: a systematic review. Frontiers in surgery. vol 10. 2023-10-13. PMID:37829601. application of virtual reality (vr) and mixed reality (mr), thus three-dimensional (3d) visualization of ias could be significant in surgical planning. 2023-10-13 2023-10-15 Not clear
Signe Winther Hasler, Jesper Folsted Kallehauge, Rasmus Hvass Hansen, Eva Samsøe, Dennis Tideman Arp, Henrik Dahl Nissen, Jens M Edmund, Uffe Bernchou, Faisal Mahmoo. Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation. Acta oncologica (Stockholm, Sweden). 2023-10-10. PMID:37815867. as magnetic resonance imaging (mri) becomes increasingly integrated into radiotherapy (rt) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired mr images pose a potential challenge to treatment accuracy. 2023-10-10 2023-10-15 Not clear
Liming Zhong, Zeli Chen, Hai Shu, Kaiyi Zheng, Yin Li, Weicui Chen, Yuankui Wu, Jianhua Ma, Qianjin Feng, Wei Yan. Multi-scale Tokens-Aware Transformer Network for Multi-region and Multi-sequence MR-to-CT Synthesis in A Single Model. IEEE transactions on medical imaging. vol PP. 2023-10-03. PMID:37782590. the superiority of magnetic resonance (mr)-only radiotherapy treatment planning (rtp) has been well demonstrated, benefiting from the synthesis of computed tomography (ct) images which supplements electron density and eliminates the errors of multi-modal images registration. 2023-10-03 2023-10-07 Not clear
W Choi, H Nourzadeh, Y Chen, C Ainsley, V Desai, A Kubli, Y Vinogradskiy, K Mooney, M Werner-Wasik, A Muelle. Novel Deep Learning Segmentation Models for Accurate GTV and OAR Segmentation in MR-Guided Adaptive Radiotherapy for Pancreatic Cancer Patients. International journal of radiation oncology, biology, physics. vol 117. issue 2S. 2023-10-03. PMID:37785478. we hypothesized that state-of-the-art deep learning (dl) segmentation models could adequately segment gtv and oars in both planning and daily fractional mr scans. 2023-10-03 2023-10-07 Not clear
J A Perez-Sanchez, R J Brisson, K E Hitchcock, R A Zlotecki, Y Badyal, C Liu, G Ya. Clinical Evaluation of Deep Learning-Based Auto-Segmentation toward MRI-Only Prostate Radiotherapy. International journal of radiation oncology, biology, physics. vol 117. issue 2S. 2023-10-03. PMID:37785525. a recent advanced mr scanner allows for an mri-only workflow owing to its ability to generate synthetic ct (mrcat) that enables accurate dose calculation and treatment planning. 2023-10-03 2023-10-07 Not clear
R Padmanabhan, J Ogunmuyiwa, B Rajagopalan, A Nasr, O D Balogu. Feasibility and Workflow Efficiency in MRI-Based HDR Brachytherapy for Cervical Cancer at a Community-Based Practice. International journal of radiation oncology, biology, physics. vol 117. issue 2S. 2023-10-03. PMID:37785661. the combined mean procedure time for mr imaging and planning reported at a high-volume brachytherapy center was 63.2 minutes. 2023-10-03 2023-10-07 Not clear
M Benayu. Dosimetry Validation of MR-Only Treatment Planning Based upon the Synthetic MRCAT Pelvis with Continuous Hounsfield Units in Prostate Cancer. International journal of radiation oncology, biology, physics. vol 117. issue 2S. 2023-10-03. PMID:37785916. mr-based radiotherapy delivery systems are increasingly encouraging treatment planning based upon an ai generated synthetic ct created from an mr image. 2023-10-03 2023-10-07 Not clear
Mayur Sharma, Pedro L Plou, Kevin Gunawan, Michael Ivan, Clark C Che. Survey assessment of utility in the preoperative magnetic resonance (MR) tractography surgical planning. World neurosurgery. 2023-09-29. PMID:37774789. survey assessment of utility in the preoperative magnetic resonance (mr) tractography surgical planning. 2023-09-29 2023-10-07 Not clear
Ali Kheyreddin, Denis Semenov, Arevik Abramya. Microsurgical excision of a ruptured distal lenticulostriate aneurysm in a child. BMJ case reports. vol 16. issue 9. 2023-09-25. PMID:37748812. mr angiography was performed in the planning phase and neuronavigation was used during surgery. 2023-09-25 2023-10-07 Not clear
Yiwen Li, Yunguan Fu, Iani J M B Gayo, Qianye Yang, Zhe Min, Shaheer U Saeed, Wen Yan, Yipei Wang, J Alison Noble, Mark Emberton, Matthew J Clarkson, Henkjan Huisman, Dean C Barratt, Victor A Prisacariu, Yipeng H. Prototypical few-shot segmentation for cross-institution male pelvic structures with spatial registration. Medical image analysis. vol 90. 2023-09-16. PMID:37716198. extensive experiments are presented in an application of segmenting eight anatomical structures important for interventional planning, using a data set of 589 pelvic t2-weighted mr images, acquired at seven institutes. 2023-09-16 2023-10-07 Not clear
Marcus Powers, John Andrew Baine. A comparison of measured and treatment planning system out-of-field dose for a 1.5 T MR linac. Physics in medicine and biology. 2023-09-12. PMID:37699399. a comparison of measured and treatment planning system out-of-field dose for a 1.5 t mr linac. 2023-09-12 2023-10-07 Not clear
F De Muzio, R Fusco, I Simonetti, F Grassi, R Grassi, M C Brunese, L Ravo, N Maggialetti, R D'Aniello, F Greco, M Gabelloni, V Granat. Functional assessment in endometrial and cervical cancer: diffusion and perfusion, two captivating tools for radiologists. European review for medical and pharmacological sciences. vol 27. issue 16. 2023-09-05. PMID:37667957. recently, functional mr techniques, namely diffusion-weighted imaging (dwi) and dynamic contrast-enhanced imaging (dce), have proved to be a precious support not only in cancer diagnosis but also in disease staging, in the therapy planning, in monitoring response to treatment and during long-term recurrence surveillance. 2023-09-05 2023-09-07 Not clear
Max Wai-Kong Law, Mei-Yan Tse, Leon Chin-Chak Ho, Ka-Ki Lau, Oi Lei Wong, Jing Yuan, Kin Yin Cheung, Siu Ki Y. A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning. Medical physics. 2023-09-04. PMID:37665783. the use of synthetic computed tomography (ct) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (mr) images, which have excellent tissue contrast. 2023-09-04 2023-09-07 Not clear