J M Mata, J Cáceres, J Lucaya, J A García-Cones. CT of congenital malformations of the lung. Radiographics : a review publication of the Radiological Society of North America, Inc. vol 10. issue 4. 1990-09-04. PMID:2377765. we found that ct was helpful in the management of these cases because it helped confirm the diagnosis, demonstrated unsuspected findings, and better depicted anatomic extent of anomalies, thus allowing better planning for surgery. 1990-09-04 2023-08-11 Not clear
B Klinge, A Petersson, P Mal. Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography. The International journal of oral & maxillofacial implants. vol 4. issue 4. 1990-08-23. PMID:2639861. the results showed that ct gave the most accurate position of the mandibular canal and is therefore probably the best method for preoperative planning of the implant surgery involving the area close to the mandibular canal. 1990-08-23 2023-08-11 Not clear
R M Glassberg, S K Sussman, M F Glickstei. CT anatomy of the internal mammary vessels: importance in planning percutaneous transthoracic procedures. AJR. American journal of roentgenology. vol 155. issue 2. 1990-08-21. PMID:2115273. ct anatomy of the internal mammary vessels: importance in planning percutaneous transthoracic procedures. 1990-08-21 2023-08-11 Not clear
Iu M Filatov, K T Mendibaev, A E Miakota, T P Tisse. [Surgical treatment of multiple arterial aneurysms of the brain]. Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko. issue 1. 1990-08-13. PMID:2164304. with the use of a diagnostic complex (cerebral angiography, eeg, ct, careful study of the medical history and the clinical picture of the disease) the aneurysm which is the source of the intracranial bleeding can be identified in most cases (93%), which is important in planning the tactics of surgical treatment. 1990-08-13 2023-08-11 Not clear
T Feyerabend, R Schmitt, E Richter, W Bohndor. [Computed tomographic determination of the target volume and the evaluation of remission after radiation of bronchial carcinoma]. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 166. issue 6. 1990-08-08. PMID:2163548. concerning determination of target volume conventional roentgen diagnostic simulator methods are much inferior to ct aided planning: as for our patients changes of the target volume were necessary in 50%, in 22% the changes were crucial. 1990-08-08 2023-08-11 Not clear
M Schratte. [CT-guided percutaneous biopsy in orthopedics. Indications--planning--technic--personal experiences, with special reference to the spine]. Der Radiologe. vol 30. issue 5. 1990-07-26. PMID:2192390. the advantages of ct guidance are most obvious in the case of lesions of the axial skeleton and pelvis: it allows precise planning of an adequate biopsy approach, better location of small cortex leaks for intraosseous entry of the puncture needle, and more sensitive selection of the best place for tissue sampling. 1990-07-26 2023-08-11 Not clear
E Tabbert, R Bollman. [3-D-irradiation planning based on the TOMOSCAN CX (Philips) computed tomograph. I. Principles of the CT-irradiation planning program. II. CT-irradiation planning for after-irradiation of breast cancer]. Radiobiologia, radiotherapia. vol 31. issue 2. 1990-07-26. PMID:2356290. adjustment of the ct to take off scan planes requires a special work-regime for irradiation planning. 1990-07-26 2023-08-11 Not clear
A E Horwitz, N Sörense. [Intraoperative ultrasound in pediatric neurosurgery]. Rontgen-Blatter; Zeitschrift fur Rontgen-Technik und medizinisch-wissenschaftliche Photographie. vol 43. issue 5. 1990-07-05. PMID:2161129. this is of particular importance, since planning of an operation is usually based on standard cuts obtained via ct or mr, whereas surgical approach is governed by the prevailing anatomico-topographical conditions. 1990-07-05 2023-08-11 Not clear
R Schmitt, M Warmuth-Metz, U Lanz, D Lucas, T Feyerabend, G Schindle. [Computed tomography of soft tissue tumors of the hand and the forearm]. Der Radiologe. vol 30. issue 4. 1990-06-28. PMID:2160673. the hand surgeon considered ct diagnostics to be very helpful in planning operations in an anatomically complex organ such as the hand. 1990-06-28 2023-08-11 Not clear
L E Frank, L A Rowley, T G Shanahan, M P Meht. Third place 1989 Alpha Cradle Award winner. Technical aspects in the use of "belly boards" for small bowel minimization. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 15. issue 1. 1990-06-25. PMID:2340081. by evaluating all patients (in both the supine position alone, and prone in the "belly board") with a dedicated treatment planning ct scanner, we have been able to achieve 80-100% reduction in the volume of small bowel within the radiation portals. 1990-06-25 2023-08-11 Not clear
W Kersjes, T Harder, P Haeffne. [Computed tomography in malignant primary bone tumors]. Rontgen-Blatter; Zeitschrift fur Rontgen-Technik und medizinisch-wissenschaftliche Photographie. vol 43. issue 4. 1990-06-21. PMID:2339256. computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, ct is especially suitable for therapy planning and evaluating response to therapy. 1990-06-21 2023-08-11 Not clear
H Bongers, R Klier, C Ozdoba, M Len. [The clinical value of contrast CT in lymph node staging in the neck region]. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. vol 152. issue 4. 1990-06-15. PMID:2160098. ct can be regarded as a reliable basis for treatment planning. 1990-06-15 2023-08-11 Not clear
K Sakata, A Akanuma, Y Aoki, K Karasawa, K Nakagawa, M Ii. Carcinoma of the maxillary sinus: the role of radiotherapy. Radiation medicine. vol 7. issue 6. 1990-05-24. PMID:2633217. intra-arterial cisplatinum infusion and treatment planning using ct scans were especially useful in improving survival. 1990-05-24 2023-08-11 Not clear
P S White, J M Robinson, I A Stewart, T Doyl. Computerized tomography mini-series: an alternative to standard paranasal sinus radiographs. The Australian and New Zealand journal of surgery. vol 60. issue 1. 1990-05-16. PMID:2327903. the planning and safety of endoscopic sinus surgery is greatly improved by ct imaging. 1990-05-16 2023-08-11 Not clear
D A Graeb, J Rootman, W D Robertson, J S Lapointe, R A Nugent, E J Ha. Orbital lymphangiomas: clinical, radiologic, and pathologic characteristics. Radiology. vol 175. issue 2. 1990-05-15. PMID:2326469. high-resolution ct is of great value in the diagnosis and preoperative treatment planning of orbital lymphangioma. 1990-05-15 2023-08-11 Not clear
D Magid, J D Michelson, D R Ney, E K Fishma. Adult ankle fractures: comparison of plain films and interactive two- and three-dimensional CT scans. AJR. American journal of roentgenology. vol 154. issue 5. 1990-05-10. PMID:2108536. two-dimensional ct was found to provide anatomic detail and information superior to either plain film or 3-d ct; 3-d ct was preferred by the surgeons for final surgical planning and for integration of the 2-d data. 1990-05-10 2023-08-11 Not clear
S Takashima, S Morimoto, J Ikezoe, S Takai, T Kobayashi, H Koyama, K Nishiyama, T Kozuk. CT evaluation of anaplastic thyroid carcinoma. AJR. American journal of roentgenology. vol 154. issue 5. 1990-05-10. PMID:2108546. ct altered surgical planning in five patients with intrathoracic extension of the thyroid tumor, and in three patients with laryngeal or esophageal invasion of the tumor. 1990-05-10 2023-08-11 Not clear
T Nishidai, Y Nagata, M Takahashi, M Abe, N Yamaoka, H Ishihara, Y Kubo, H Ohta, C Kazus. CT simulator: a new 3-D planning and simulating system for radiotherapy: Part 1. Description of system. International journal of radiation oncology, biology, physics. vol 18. issue 3. 1990-05-10. PMID:2318683. ct simulator: a new 3-d planning and simulating system for radiotherapy: part 1. 1990-05-10 2023-08-11 Not clear
T Nishidai, Y Nagata, M Takahashi, M Abe, N Yamaoka, H Ishihara, Y Kubo, H Ohta, C Kazus. CT simulator: a new 3-D planning and simulating system for radiotherapy: Part 1. Description of system. International journal of radiation oncology, biology, physics. vol 18. issue 3. 1990-05-10. PMID:2318683. a real time ct-linked 3-d treatment planning system, called a ct simulator, has been developed. 1990-05-10 2023-08-11 Not clear
T Nishidai, Y Nagata, M Takahashi, M Abe, N Yamaoka, H Ishihara, Y Kubo, H Ohta, C Kazus. CT simulator: a new 3-D planning and simulating system for radiotherapy: Part 1. Description of system. International journal of radiation oncology, biology, physics. vol 18. issue 3. 1990-05-10. PMID:2318683. the basic system consists of a ct scanner, a multi-image display component, a treatment planning device with real time visual optimization, and a laser beam projecting component. 1990-05-10 2023-08-11 Not clear