Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
R Oozeer, B Chauvet, B J Toy, C Berger, R Garcia, C Felix-Faure, H Le Thanh, F Rebou. [Definition of prostatic contours using tomodensitometric slices: study of differences among radiotherapists and between examinations]. Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique. vol 3. issue 4. 1999-10-07. PMID:10486545. |
the contours of the second scan were compared to the planning contours after image fusion based on manual superimposition of bony anatomy of the two sets of ct images. |
1999-10-07 |
2023-08-12 |
Not clear |
R Oozeer, B Chauvet, B J Toy, C Berger, R Garcia, C Felix-Faure, H Le Thanh, F Rebou. [Definition of prostatic contours using tomodensitometric slices: study of differences among radiotherapists and between examinations]. Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique. vol 3. issue 4. 1999-10-07. PMID:10486545. |
new techniques for planning ct acquisition are needed to decrease the discrepancies due to contouring. |
1999-10-07 |
2023-08-12 |
Not clear |
J Kress, S Minohara, M Endo, J Debus, T Kana. Patient position verification using CT images. Medical physics. vol 26. issue 6. 1999-10-04. PMID:10436895. |
this single slice is registered to the planning ct cube using automated image registration algorithms. |
1999-10-04 |
2023-08-12 |
Not clear |
M J Ackerma. The Visible Human Project: a resource for anatomical visualization. Studies in health technology and informatics. vol 52 Pt 2. 1999-09-09. PMID:10384616. |
the nlm planning panel on electronic imaging recommended that nlm should undertake the building a digital image library consisting of computerized tomography (ct) and magnetic resonance (mr) images, and cryosection images of a representative, carefully selected and prepared male and female cadaver--the "visible human projectj." |
1999-09-09 |
2023-08-12 |
human |
N Sugano, K Ohzono, T Nishii, K Haraguchi, T Sakai, T Och. Computed-tomography-based computer preoperative planning for total hip arthroplasty. Computer aided surgery : official journal of the International Society for Computer Aided Surgery. vol 3. issue 6. 1999-08-17. PMID:10379982. |
for precise preoperative planning in total hip arthroplasty (tha), we developed a technique of computed tomography (ct)-based computer preoperative planning and compared this technique with the single x-ray and template method generally used. |
1999-08-17 |
2023-08-12 |
human |
K D Hopper, A T Iyriboz, S W Wise, J A Fornadle. The feasibility of surgical site tagging with CT virtual reality of the paranasal sinuses. Journal of computer assisted tomography. vol 23. issue 4. 1999-08-16. PMID:10433279. |
the purpose of this work was to evaluate the feasibility of tagging (highlighting) surgical sites using volumetric ct virtual reality of the paranasal sinuses in the planning for endoscopic sinus surgery. |
1999-08-16 |
2023-08-12 |
Not clear |
H Hiramatsu, K Enomoto, T Ikeda, M Mukai, T Furuta, H Hattori, Y Tanami, T Ohashi, M Kitajima, K Hiramats. Three-dimensional helical CT for treatment planning of breast cancer. Radiation medicine. vol 17. issue 1. 1999-08-04. PMID:10378650. |
three-dimensional helical ct for treatment planning of breast cancer. |
1999-08-04 |
2023-08-12 |
Not clear |
H Hiramatsu, K Enomoto, T Ikeda, M Mukai, T Furuta, H Hattori, Y Tanami, T Ohashi, M Kitajima, K Hiramats. Three-dimensional helical CT for treatment planning of breast cancer. Radiation medicine. vol 17. issue 1. 1999-08-04. PMID:10378650. |
the role of three-dimensional (3d) helical ct in the treatment planning of breast cancer was evaluated. |
1999-08-04 |
2023-08-12 |
Not clear |
A Doyle, S Hawkins, L Ashle. Unenhanced helical CT of ureteral stones in planning treatment: patient selection criteria. AJR. American journal of roentgenology. vol 173. issue 1. 1999-07-28. PMID:10397137. |
unenhanced helical ct of ureteral stones in planning treatment: patient selection criteria. |
1999-07-28 |
2023-08-12 |
Not clear |
K Imai, K Tsujiguchi, C Toda, E Enoki, K C Sung, H Sakamoto, S Kitano, M Hatoko, S Tajim. Reduction of operating time and blood transfusion for craniosynostosis by simulated surgery using three-dimensional solid models. Neurologia medico-chirurgica. vol 39. issue 6. 1999-07-27. PMID:10396116. |
preoperative planning of craniofacial synostosis can be achieved through the use of two- or three-dimensional (3d) computed tomography (ct) images and by 3d solid models. |
1999-07-27 |
2023-08-12 |
Not clear |
N Bhattacharyy. Test-retest reliability of computed tomography in the assessment of chronic rhinosinusitis. The Laryngoscope. vol 109. issue 7 Pt 1. 1999-07-27. PMID:10401840. |
despite its central role in the diagnosis and treatment planning for chronic rhinosinusitis, the sinus ct represents a "snapshot in time." |
1999-07-27 |
2023-08-12 |
Not clear |
T Kamada, H Tsujii, J E Mizoe, Y Matsuoka, H Tsuji, Y Osaka, S Minohara, N Miyahara, M Endo, T Kana. A horizontal CT system dedicated to heavy-ion beam treatment. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 50. issue 2. 1999-07-26. PMID:10368048. |
a horizontal helical ct system to be used for 3-d treatment planning and for positioning verification of patients in seated position was installed in the treatment room with a fixed horizontal heavy-ion beam line. |
1999-07-26 |
2023-08-12 |
Not clear |
F Watzinger, W Birkfellner, F Wanschitz, W Millesi, C Schopper, K Sinko, K Huber, H Bergmann, R Ewer. Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. vol 27. issue 2. 1999-07-16. PMID:10342142. |
the aim of the system is the intraoperative transfer of preoperative planning on radiographs or ct scans on the patient, in real-time, and independent of the position of the patient's head. |
1999-07-16 |
2023-08-12 |
Not clear |
M Schreckenberger, U Spetzger, O Sabri, P Meyer, G Schulz, B Hermanns, G Krombach, J Gilsbach, U Buel. Preoperative PET activation for assessment of motor cortex area in precentral chondroma. Surgical neurology. vol 52. issue 1. 1999-07-07. PMID:10390168. |
a main problem in the preoperative planning for precentral tumors is the exact assessment of the spatial relationship between the tumor and the functionally relevant brain areas, which may be difficult using only morphologically oriented imaging (ct, mri). |
1999-07-07 |
2023-08-12 |
Not clear |
S Knipping, K Neumann, W Burkert, U Krause, A Berghau. [Unusual intra-extracranial extension of meningioma of the lateral skull base]. HNO. vol 47. issue 1. 1999-07-02. PMID:10093790. |
since an extracranial meningioma can present as a mass lesion of the lateral skull base, ct and mri scans are essential in preoperative surgical planning. |
1999-07-02 |
2023-08-12 |
Not clear |
R K Valicenti, J W Sweet, W W Hauck, R S Hudes, T Lee, A P Dicker, F M Waterman, P R Anne, B W Corn, J M Galvi. Variation of clinical target volume definition in three-dimensional conformal radiation therapy for prostate cancer. International journal of radiation oncology, biology, physics. vol 44. issue 4. 1999-07-02. PMID:10386652. |
currently, three-dimensional conformal radiation therapy (3d-crt) planning relies on the interpretation of computed tomography (ct) axial images for defining the clinical target volume (ctv). |
1999-07-02 |
2023-08-12 |
Not clear |
T Craig, D Brochu, J Van Dy. A quality assurance phantom for three-dimensional radiation treatment planning. International journal of radiation oncology, biology, physics. vol 44. issue 4. 1999-07-02. PMID:10386655. |
three-dimensional (3d) radiation treatment planning is facilitated through the use of computerized radiation treatment planning systems (rtpss) and ct simulators (ct-sims). |
1999-07-02 |
2023-08-12 |
Not clear |
J T Rhea, P M Rao, R A Novellin. Helical CT and three-dimensional CT of facial and orbital injury. Radiologic clinics of North America. vol 37. issue 3. 1999-06-30. PMID:10361543. |
the indications for ct include detection of suspected fractures and preoperative planning. |
1999-06-30 |
2023-08-12 |
Not clear |
J S Lee, A B Jani, C A Pelizzari, D J Haraf, E E Vokes, R R Weichselbaum, G T Che. Volumetric visualization of head and neck CT data for treatment planning. International journal of radiation oncology, biology, physics. vol 44. issue 3. 1999-06-08. PMID:10348301. |
volumetric visualization of head and neck ct data for treatment planning. |
1999-06-08 |
2023-08-12 |
Not clear |
J S Lee, A B Jani, C A Pelizzari, D J Haraf, E E Vokes, R R Weichselbaum, G T Che. Volumetric visualization of head and neck CT data for treatment planning. International journal of radiation oncology, biology, physics. vol 44. issue 3. 1999-06-08. PMID:10348301. |
to demonstrate the utility of volume rendering, an alternative visualization technique to surface rendering, in the practice of ct based radiotherapy planning for the head and neck. |
1999-06-08 |
2023-08-12 |
Not clear |